Presentation is loading. Please wait.

Presentation is loading. Please wait.

1 Video, Voice, and Broadband Connectivity Solutions -1- MDU Networking using CORINEX products including the new 600 Mbps Corinex MDU Gateway! www.corinex.com.

Similar presentations


Presentation on theme: "1 Video, Voice, and Broadband Connectivity Solutions -1- MDU Networking using CORINEX products including the new 600 Mbps Corinex MDU Gateway! www.corinex.com."— Presentation transcript:

1 1 Video, Voice, and Broadband Connectivity Solutions -1- MDU Networking using CORINEX products including the new 600 Mbps Corinex MDU Gateway! www.corinex.com

2 2 Video, Voice, and Broadband Connectivity Solutions -2- Corinex Enterprise Products Powerline Networking (Common Power Meter) Powerline Networking (Individual Power Meters) Coaxial Networking Coax and Powerline Networking (Common Power Meter)

3 3 Video, Voice, and Broadband Connectivity Solutions -3- Corinex AV200 Enterprise Powerline Ethernet Adapter Corinex AV200 Enterprise Powerline Wall Mount Corinex Installation Training Corinex MDU Gateway Powerline and Coax MDU Networking – Product family Corinex 5+1 Phase Coupler MDU Gateway creates a Powerline or Coaxial backbone AV200 Enterprise Powerline Ethernet Adapter CPE AV200 Enterprise Powerline Wall Mount CPE AV200 Enterprise CableLAN CPE 5+1 and 11+1 Phase Coupler (for bypassing Individual Meters) Corinex High Pass and Mode Filters Installation Training to teach hardware and software configuration Corinex AV200 Enterprise CableLAN Adapter Corinex 11+1 Phase Coupler Corinex High Pass Filter Powerline networking components Coaxial networking components Corinex Mode Filters

4 4 Video, Voice, and Broadband Connectivity Solutions -4- MDU Gateway - Features 3 AV200 200 Mbps Powerline Modules 3 * 200 Mbps = 600 Mbps Coaxial or Powerline input/outputs Modules act as a Master / Head End 2-34 MHz operation, 2-30MHz in EU (mode 6) Optional Frequency Band segmenting using: 2-12 MHz (mode 1) 13-23 MHz (mode 2) 24-34 MHz (mode 3) Optional Built in Filters to support Frequency Band segmenting Up to 32 users (CPE) per Module / 96 users per MDU Gateway (Coax or Common Power Meter in building) OR Up to 11 electrical meters connected per Module / 33 per MDU Gateway (Individual Power Meters in building) World’s ONLY enterprise MDU product! World’s ONLY 600 Mbps product! Corinex MDU Gateway

5 5 Video, Voice, and Broadband Connectivity Solutions -5- MDU Gateway – Back Panel and Interfaces Each Module has Coaxial and Powerline Input/Outputs Within a single MDU Gateway a mix of Coax and Powerline input/outputs between modules is allowed Example: Module 1: Coax Module 2: Powerline Module 3: Powerline or Module 1: Coax Module 2: Coax Module 3: Powerline or … DO NOT use both Coax AND Powerline outputs on same module-interface Module 1 Powerline Input/Output Module 2 Powerline Input/Output Module 3 Powerline Input/Output Module 1 Coax Input/Output Module 2 Coax Input/Output Module 3 Coax Input/Output Power On/OFF Power Connection 10/100 BaseT

6 6 Video, Voice, and Broadband Connectivity Solutions -6- Corinex Enterprise Products Powerline Networking (Common Power Meter) Powerline Networking (Individual Power Meters) Coaxial Networking Coax and Powerline Networking (Common Power Meter)

7 7 Video, Voice, and Broadband Connectivity Solutions -7- Phase 1 Phase 2 Phase 3 Electrical Dist. Panel 1st Floor 2nd Floor 3rd Floor 4th Floor 5th Floor 6th Floor Scenario 1: (Hotels, Barracks, Residential) 1 electrical phase per 2 floors First 6 floors served by one transformer Additional floors served by other transformer(s) Same scenario for each phase serving different number of floors Powerline Networking (Common Power Meter) M.Power Distrib. Panel Pre Deployment Situation Main Power Meter

8 8 Video, Voice, and Broadband Connectivity Solutions -8- Optical Fiber (or other broadband) Scenario 1: Pure Powerline Networking: Powerline Backbone (bypass meter) Powerline within floor 1 module for each of 3 phases Direct Connection (no coupler) AV200 Powerline CPE in each apartment/flat served Up to 32 users per phase 3 frequency bands (Mode 1,2,3 for the 3 modules) Post Deployment Situation Phase 1 Phase 2 Phase 3 Electrical Dist. Panel 1st Floor 2nd Floor 3rd Floor 4th Floor 5th Floor 6th Floor BROADBAND SIGNAL INJECTED IN POWERLINES Plug MDU Gateway into each electrical phase at 3 wall outlets of distribution panel Power Distrib. Panel Main Power Meter MDU Gateway Mode 2 Mode 3 Mode 1 MDU Gateway Module 1 = Mode 1 Module 2 = Mode 2 Module 3 = Mode 3 TIP: Mode 1 propagates furthest, then Mode 2, then Mode 3 Powerline Networking (Common Power Meter) Power Distribution Panel

9 9 Video, Voice, and Broadband Connectivity Solutions -9- Corinex Enterprise Products Powerline Networking (Common Power Meter) Powerline Networking (Individual Power Meters) Coaxial Networking Coax and Powerline Networking (Common Power Meter)

10 10 Video, Voice, and Broadband Connectivity Solutions -10- Scenario 2: Residential Apartments/Flats: Power Meters attenuate Powerline signals by 5 to 45dB MDU Gateway Powerline Backbone 5+1 / 11+1 Electrical phase coupler AV200 Powerline CPE In-Home Full Frequency band (mode 6) Powerline Networking (Individual Power Meters) Pre Deployment Situation

11 11 Video, Voice, and Broadband Connectivity Solutions -11- INOUT Meter Up to 11 Power Meters Corinex MDU Gateway Module 1 Mode 6 Corinex 11+1 Phase Coupler INOUT Meter Up to 11 Power Meters INOUT Meter Up to 11 Power Meters Ethernet 10/100 Base-T Electrical Wire Electrical Wire Electrical Wire Corinex 5+1 Phase Coupler Corinex 11+1 Phase Coupler Post Deployment Situation Use either 5+1 or 11+1 Phase Coupler on each module to connect up to 11 electrical meters per module-interface To individual Apartments / Flats with AV200 Powerline CPE for In-Home connectivity From Utility Power Feed Each Module-interface gives a 200 Mbps connection Powerline Networking (Individual Power Meters) Module 2 Mode 6 Module 3 Mode 6

12 12 Video, Voice, and Broadband Connectivity Solutions -12- Corinex Enterprise Products Powerline Networking (Common Power Meter) Powerline Networking (Individual Power Meters) Coaxial Networking Coax and Powerline Networking (Common Power Meter)

13 13 Video, Voice, and Broadband Connectivity Solutions -13- Coaxial Networking Scenario 3: (Hotels, Residential, Barracks) 1 coax panel per floor Additional floors on same coax line ≤ 32 users per floor Pre Deployment Situation Main Cable Coax Dist. Panel Apart 1 Apart 2 Apart 3 Apart 32 Apart 1 Apart 2 Apart 3 Apart 32 Apart 1 Apart 2 Apart 3 Apart 32 Splitter Continue to the next floor

14 14 Video, Voice, and Broadband Connectivity Solutions -14- Scenario 3: Pure Coax Networking: Coax Backbone All 3 Modules inject signal Coax within floor 1 Module (up to 32 users) per Coax distribution panel AV200 CableLAN CPE In-Home 3 frequency bands (modes 1,2,3) Add more segments to expand (add High Pass Filter and another MDU Gateway on 4 th Floor connected via Ethernet ) Post Deployment Situation Main Cable COAX BACKBONE Corinex Mode 1 Filter Coax Dist. Panel Apart 1 Apart 2 Apart 3 Apart 32 Apart 1 Apart 2 Apart 3 Apart 32 Apart 1 Apart 2 Apart 3 Apart 32 3 way Splitter Corinex Mode 2 Filter Corinex Mode 3 Filter Splitter MDU Gateway Module 1 = Mode 1 Module 2 = Mode 2 Module 3 = Mode 3 Broadband Source Continue to the next floor Mode 1 Mode 2 Mode 3 Mode 1 Mode 2 Mode 3 Coaxial Networking Mode 1 Mode 2 Mode 3 Mode 1 Mode 2 Mode 3

15 15 Video, Voice, and Broadband Connectivity Solutions -15- Coaxial Networking – Creating the Coaxial Backbone Main Cable Coax Dist. Panel Splitter Broadband Source OPTION 3: MDU Gateway Mode 6 OPTION 1: Corinex Head End OPTION 2: Corinex AV200 Enterprise CableLAN OPTION 3: MDU Gateway Coaxial Backbone Injection Unit Options COAX BACKBONE Continue to the next floor

16 16 Video, Voice, and Broadband Connectivity Solutions -16- Scenario 4: (Hotels, Residential, Barracks) 1 coax panel per floor Additional floors on same coax line > 32 users per floor Pre Deployment Situation Main Cable Coax Dist. Panel Apart 1 Apart 2 Apart 3 Apart 32 Apart 1 Apart 2 Apart 3 Apart 32 Apart 1 Apart 2 Apart 3 Apart 32 Splitter Continue to the next floor Coaxial Networking

17 17 Video, Voice, and Broadband Connectivity Solutions -17- Scenario 4: MDU Networking Solution Coax Backbone 1 Module to carry input Coax within floor 1-2 Modules for each coax distribution panel (up to 64 users) AV200 CableLAN CPE In-Home Full Frequency band on Backbone (mode 6), Full Frequency band on floor (≤ 32 users) or Partial frequency band on floor (> 32 users, mode 1/2) Post Deployment Situation Continue to the next floor COAX BACKBONE Apart 1 Apart 2 Apart 3 Apart 4 Apart 64 Coaxial Distribution Panel Apart 1 Apart 2 Apart 3 Apart 4 Apart 64 Coaxial Distribution Panel Apart 1 Apart 2 Apart 3 Apart 4 Apart 64 Coaxial Distribution Panel Splitter MDU Gateway Corinex High Pass Filter Splitter Mode 6 or Mode 1/2 Mode 6 Coaxial Networking Mode 6 Coax Backbone

18 18 Video, Voice, and Broadband Connectivity Solutions -18- Corinex Enterprise Products Powerline Networking (Common Power Meter) Powerline Networking (Individual Power Meters) Coaxial Networking Coax and Powerline Networking (Common Power Meter)

19 19 Video, Voice, and Broadband Connectivity Solutions -19- Coax and Powerline Networking (Common Power Meter) Scenario 5: Coaxial / Powerline Hybrid Coax Backbone 1 Input Module Powerline within floor 1 Module for each electrical panel = 32 users per panel Direct Coupling to Power – No Electrician Required AV200 Powerline CPE In- Home Full Frequency band (mode 6) on backbone and floor COAX BACKBONE Apart 1 Apart 2 Apart 3 Apart 4 Apart 32 Electrical Subpanel Apart 1 Apart 2 Apart 3 Apart 4 Apart 32 Electrical Subpanel Apart 1 Apart 2 Apart 3 Apart 4 Apart 32 Electrical Subpanel Splitter Plug directly (any Electrical Phase) MDU Gateway Post Deployment Situation Mode 6 Plug directly (any Electrical Phase) Plug directly (any Electrical Phase) Mode 6 Coax Backbone Continue to the next floor

20 20 Video, Voice, and Broadband Connectivity Solutions -20- Scenario 6: Coaxial/Powerline Hybrid Coax Backbone 1 Input Module Powerline within floor 2 Modules for each electrical panel = 64 users per panel Direct Coupling to Power – No Electrician Required AV200 Powerline CPE In-Home Full Frequency band on Backbone (mode 6), Segmented Frequency band on floors (modes 1,2,3) Post Deployment Situation Splitter COAX BACKBONE Apart 1 Apart 2 Apart 3 Apart 4 Apart 64 Electrical Subpanel Apart 1 Apart 2 Apart 3 Apart 4 Apart 64 Electrical Subpanel Mode 1 Mode 2 Mode 3 Mode 1 Mode 2 Mode 3 Apart 1 Apart 2 Apart 3 Apart 4 Apart 64 Electrical Subpanel MDU Gateway Coax and Powerline Networking (Common Power Meter) Mode 6 Coax Backbone Continue to the next floor

21 21 Video, Voice, and Broadband Connectivity Solutions -21- MDU Networking – Summary Corinex MDU Networking Products: Allow you to network an entire building regardless of size or shape or metering Allow you to network an entire building without adding any additional wiring Offer the highest performance MDU Networking available Corinex increases buildings property owners investment value Corinex MDU solution guarantees you very quick ROI and investment protection as the broadband network becomes part of your intelligent building property. Corinex MDU Gateway is the only product of its kind in the industry – 600Mbps! MDU Broadband equipment revenues will triple in the next 4 years – The Corinex MDU Gateway allows you to win your share!


Download ppt "1 Video, Voice, and Broadband Connectivity Solutions -1- MDU Networking using CORINEX products including the new 600 Mbps Corinex MDU Gateway! www.corinex.com."

Similar presentations


Ads by Google