Download presentation
Presentation is loading. Please wait.
Published byLenard Weaver Modified over 9 years ago
1
Using automation to prepare chemotherapy David Leonard Executive Lead Pharmacist Aseptics & Clinical Trials November 2009
2
Imperial College Healthcare NHS Trust Hammersmith Hospital – Postgraduate Teaching & Research Charing Cross Hospital – Undergraduate Teaching & Research Queen Charlottes and Chelsea – Postgraduate Women and Children St Mary’s Hospital – Undergraduate teaching & Research
3
The Trust Income –>£650 million ‘healthcare’ per annum –>£150 million R&D and teaching Activity –>170,000 inpatients pa –>690,000 outpatients pa Staff –9,700
4
ICHNT Aseptic Units MHRA licensed units at Charing Cross & Hammersmith 27,000 doses of chemotherapy pa 7,000 PN bags pa (neonatal & adult) And increasingly…….clinical trial work including gene therapy
5
The Imperial medicines automation experience Dispensary automation since 2003….. –Rowa and Packpicker –CII safe Ward based automation since 2002…. –ServeRx ward system –ServeRx night cabinet –Pyxis cabinets Aseptic nothing since 90’s –Baxa pumps –Automix for neonatal PN
6
CytoCare The video
7
What did we hope CytoCare would do for us? Reduce repetitive strain injury Improve safety Improve efficiency Reduce costs
8
But first we needed to validate it! We need to convince –Ourselves –& – the MHRA » that is was safe to use….. »Only then can we find out if it delivers our hopes…..
9
European Project started April 2007 & finished in March 2009 3 Pilot sites collaborating 3 domains : –safety –efficiency –human aspects www.safechemo.eu SafeChemo Project
10
Early issues Delivered in Dec 2006 –Uncapping & swabbing of vials –No check on bags Replaced in May 2007 – Heat in main chamber
11
Safety Validation results…... Software GAMP compliant Recognition of ingredients Sterility of products (final product) & operator validation Sterility of Partially used vials
12
Validation results……(continued) Physical monitoring Cross product contamination Precision Internal Balance
13
Precision of Preparation
14
Microbiological Monitoring Preliminary results –In unclassified room, CytoCare not cleaned –CytoCare under differing conditions Air supply to CytoCare on or off UV light on or off After cleaning
15
1.3 Contact plates
16
1.3 Swabs
17
MHRA view Reviewed approach Lots of comments & feedback Approval to use in principle given Nov 2008
18
Product phasing Phase 1 : Solution into a syringe Phase 2 : Solution into a bag Phase 3 : Powder into a syringe Phase 4 : Powder into a bag Phase 5 : ?other containers
19
“Go live” 30 SOP’s 5FU syringes Simple In solution Cheap Made in advance High usage
20
First live dose made!
21
Aseptic Staff views
22
Additional validation work Sterility of bags as a final product - completed Jan 09 Recognition work not transferable from product to product Disinfection of line Check database entries for each new drug
23
Current Products Nov 2008 : 5 FU syringes Jan 2009 : 5 FU bags February 2009 : 5FU for Hammersmith site Apr 2009 : Carboplatin & Cisplatin bags
24
Live results 263 5FU syringes for patient use 39 failures Current failure rate = 14.8% 424 bags 42 failures Current failure rate = 9.9%
25
Reasons for failures Aspiration “Sleeping” Recognition Operator error Bung in syringe Barcodes Gripper
26
Additional considerations Brief Nursing staff : –differences in labels –syringe sizes –graduations What happens if recall Train staff – also include troubleshooting
27
Next steps Install new software to improve operational use, to address: –maximum of 8 doses per cycle –Re-enter patients data for each dose & each drug –CytoCare weighs repeatedly Methotrexate, Paclitaxel, Etoposide Powders Make more doses for other sites within the Trust
28
Summary Exciting piece of automation Lots of highs & lows over the last 3 years Validated & approved by MHRA in principle Still believe it will : –reduce RSI & costs –improve safety & efficiency Now using operationally & working on reducing failures, improving efficiency & increasing the range of products But………..
30
Questions?
31
CytoCare
32
Main chamber
33
Waste bin & powder spinner
Similar presentations
© 2025 SlidePlayer.com. Inc.