Download presentation
1
Mikrolab Aarhus A/S, Denmark
Vagn Aagaard Hansen
2
ML DK World Denmark
3
ML + Europe
4
ML - all over the world
5
Mikrolab Aarhus A/S The company is situated in Aarhus (in Jutland) and serves customers all over Denmark. Some of ML’s own products are exported. ML represents several companies of good reputation from all over the world. Aarhus
6
Oxidation stability tests
Vagn Aagaard Hansen Mikrolab Aarhus A/S 8270 Hojbjerg - Denmark
7
Oxidation - rancidity Oxidation gives rancid taste
Maintain original taste and composition By proper storage Addition of antioxidants
8
Use antioxidants reduces rate of oxidation: 1. longer shelf life
2. more efficient production 3. cheaper distribution 4. better economy
9
Accelerated tests Quality of raw material Test of various antioxidants
type concentration Optimize the product Test of final product
10
What is measured? = IPwith antiox. / IPwithout antiox.
Oxygen consumption = pressure drop IP = Induction period = Time from start until rate of oxygen uptake increases (related to temp.) PF = Protection factor = IPwith antiox. / IPwithout antiox. LE = Life extension = 100 x (PF - 1) %
11
Predicted shelf life IP = 50 hours (at 60 oC)
Reaction rate (doubles) by heating 10 oC Shelf life at 20 oC = 24 x 50 = 800 hours This is only a thumb rule and must be used with care
12
ML Instrumentation ML Oxidograph™ ML Oxipres™
pure oil and fat (no water present) ML Oxipres™ oil and fat food products
13
ML OXIDOGRAPH™ Oxygen at elevated temperature Stirred sample
Start at atmospheric pressure Pressure drop measured Static test - realistic test conditions Volatiles stay with the sample Volatile pro-oxidants Volatile anti-oxidants Volatile reaction products
14
ML Oxidograph™ APPLICATIONS: Pure oils and fats
liquid at test temperature no water should be present
15
ML OXIPRES™ Oxygen at elevated temperature
Overpressure in a SS-vessel (5 bar) Pressure is measured over time Static test - realistic test conditions Heterogenous samples
16
ML OXIPRES™ New features: Stirring of liquid samples
Collection of volatiles (ATD)
17
Oxipres with Stirrer Module
18
Top-holder
19
ML OXIPRES™ APPLICATIONS: Peanuts Snacks, biscuits Mayonaise Fish meal
Cookies, Sponge cake Meat Cattle feed Pet food
20
Procedure Turn on the block heater Weigh the sample in the vial
Place the sample vial in the pressure vessel Flush with oxygen Apply pressure Place the bomb in the heater Start the test
21
Resumè ML Oxidograph™ ML Oxipres™ Pure oil and fat 6 positions
°C 1/5 V analog output Heterogenous samples modular: 2, 4 or 6 pos. °C 1/5 V analog output
22
Installation 230 (120) V AC Oxygen cylinder
Cylinder pressure regulator - 1/8” tubing Filling station PC (Windows XP or Vista) USB-converter Paralog (Ver. 3 software) or Recorder (2-6 channels)
23
ML OxipresTM - 1 module
24
ML OxipresTM - Control unit
ON/OFF
25
ML OxipresTM - Control unit
26
ML OxipresTM - 3 modules
27
3 Oxipres set-up
28
Paralog™ Software Collects data from OXI-instruments
Shows instruments and positions Shows curves Automatic (or manual) IP detection Prints report Data stored in ASCII format (> Excel) Pick old data Print old data report Select language (future)
29
Requirements: PC (or LapTop) w. Win XP or Vista
Processor: Intel Pentium III (500 MHz) or higher Free hard disk space: Program: 1 GB Test files: 5 GB RAM, XP: 512 MB (Win XP) Slots: USB1 or higher (1 for each converter or use a USB-hub) Monitor: x 768 Color printer USB converter PICOtech (between the instrument and the PC) – takes up to 11 signals Java Driver for the USB-converter (PICOtech) Software, Paralog 3
30
ML OxipresTM - Potato Chips
31
ML OxipresTM - output bar 4 h Chips at 90 oC Time
32
ML OxipresTM - Fish oil
33
ML OxipresTM - output
34
Oxipres - bomb + reaction vessel
Stainless steel bomb Glass reaction vessel
35
ML Oxipres - Lid lifter Suction lifter
36
ML Oxipres - filling station
Fast connection by quick-connects Fill/vent 2 bombs at the same time (same pressure) Mounts on the table
37
ML OxidographTM
38
Oxidograph - glassware
Reaction vessel Top with threads G 14 Tube with stop Screw cap B 34 O-ring Antilock ring Screw cap B 14 Silicone ring 7x12 mm
39
Oxipres - Schaal Oven Test
Weigh a set of scintillation vials - add 1,0 gram of sample to each Place up to 6 vials in each bomb Close the bomb - add oxygen to 5 bars Place the bomb in the block heater for x hours Release the pressure, let the vial cool down and weigh again Repeat the procedure y times
40
ML Oxidograph/Rancimat
41
ML Oxidograph/Rancimat
42
Comparison with the Rancimat
43
Some users of ML OXI-instruments
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.