Local Exhaust Fans
3
Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot H20 heaters Woodstoves Leaky chimneys
4
Multi Point Ventilation
5
Heat Recovery Ventilator
6
HRV
8
Bath Ventilation
9
Bathroom Exhaust Fans
10
CODE for Baths with bathing or spas facilities: Minimum 80 CFM Intermittent Ventilation required or Continuous Ventilation System at 20 cfm CODE for Toilet Rooms without bathing or spas facilities: 3SF Minimum Window ½ of which must be openable Minimum 50 CFM Intermittent Ventilation
11
Home Ventilation Institute Recommendations - Baths Bathrooms to 80SF - 80CFM fan (Code) Bathrooms 81sf to 100 sf – 1 cfm per square foot (~ 8 air changes/hour) Bathrooms over 100 sf add the CFM for each fixture Allow 50 CFM per standard toilets, shower and steam shower (put on timer) Allow 100 CFM per Whirlpool, garden and hot tubs HVI recommends continuous ventilations as augmentation to intermitent venilation
12
Bathroom Exhaust Fans A toilet in its own enclosure should have its own fan Fans approved for wet areas should be placed over or very near the shower or tub when possible. Bath doors should be undercut at least 3/4” Leave fan on for 20 minutes after use of the bathroom
13
Web Resource HVACquick.com Home Ventilation Institute
14
Ventilation Considerations Fan Type Propeller Fan – Limited air capacity and noisy Axial Fan – Better air movement but still noisy Centrifugal Blower (Squirrel Cage) The best
15
Propeller Fan
16
Axial Fan
17
Centrifugal Blower
18
Sound Levels Sound is measured in Sones 1-Sone equals the loudness of a pure tone having a frequency of 1,000 hertz at 40 decibels.
19
Decibels 0 -The softest sound a person can hear with normal hearing 10 -Normal breathing 20 Whispering at 5 feet 30 Soft whisper 50 Rainfall 60 Normal conversation 110 Shouting in ear 120 Thunder.9 Sones = approx. 28.2 decibels
20
Sones The Home Ventilation Institute sets a limit of 9.0 sones for kitchen fans up to 500 CFM Reference – A fan with a sone rating of 8.0 sones is twice as loud as one rated at 4.0 sones. Reference - Refrigerators run at about 1.0 sone.
22
In-Line Ventilator Fan 110 CFM 1.0 Sones 210 CFM 2.0 Sones
23
Broan Silent Series 110 cfm.7 Sones
24
Switching Fans Humidistat
25
Kitchen Ventilation
26
Kitchen Exhaust Fans CODE (ASHRAE) The American Society of Heating, Refrigerating and Air-Conditioning Engineers 100 CFM Intermittent Or 25 CFM Continuous
27
Home Ventilation Institute Recommendations - Kitchens Wall Mount Hoods – 100 cfm per foot of width Island Mount Hoods – 150 cfm per foot of width
28
Air Flow Rules of Thumb Rule of Thumb 1: Take the hood area (in square feet) and multiply it by 75 to get the CFM (cubic feet per minute) for a wall hood, or multiply it by 100 for an island hood. Rule of Thumb 2: Allow 15 air changes per hour (ACH) for the kitchen. Take the kitchen volume (length x width x height) and divide by 4 to get the required CFM.
29
Air Flow Rules of Thumb Rule of Thumb 3: Allow 1 CFM per 100 BTU's per hour (BTUH) heat output. Take the output of the oven and cooktop (if together or close) and divide by 100 to get the required CFM. Rule of Thumb 4: (this applies to commercial type ranges) Allow 100 CFM per linear foot of hood. Take the perimeter of the hood and multiply it by 100 to get the required CFM. Which rule of thumb is the best one to use? The most popular rules of thumb are #1 and #3. We typically use rule of thumb #1 when we size fans.
30
NKBA Recommendations
31
Multi Point Ventilation
32
Vented Hood System
33
Recirculating Fan in Microwave Combo
34
Kitchen Ventilation (HOGSS) Heat Odor Grease Steam Smoke
35
Recirculating Range Hood
36
Recirculating Ventilation System This type of system will only remove two Heat Steam
37
Downdraft
38
Down Draft Ventilation
40
Range Hood Installation
50
Integral Fan Vented Through Roof
51
In Line Fan
52
Integral Through Soffit
53
Remote Ventilator
54
Through Crawlspace
55
Down Draft Through Floor
56
Down Draft Through Roof
57
Kitchen Ventilation Considerations Fan – 300 CFM minimum Ducted Duct run lengths Interior Fan (power) Keep duct runs as short and straight as possible. 6” round or 3 ¼” x 10 rectangular ducts Maximum run = 25’ maximum
58
Kitchen Ventilation Considerations Exterior or In-Line Fan (power) 9” round or 3 ¼” x 14” rectangular duct Maximum run = 55’ maximum