Download presentation
Presentation is loading. Please wait.
Published byArthur Robbins Modified over 9 years ago
1
United States Air Force - Eglin Air Force Base
2
Eglin Air Force Base Energy Management Air Force Energy Plan (overview) Air Force Infrastructure Energy Plan (overview) Energy Conservation Projects at Eglin Energy Management System (EMS) – Load Shedding/Peak Demand (RTP)
3
Eglin Air Force Base Energy Management
5
Culture Change: Changing the Air Force culture is critical to achieving the Air Force’s Energy Vision. Increase Supply: The Air Force is committed to increasing the amount of energy supplies available to enhance our nation’s energy security.. Reduce Demand: The Air Force is committed to reducing aviation, ground operations, and installation energy demand.
6
Eglin Air Force Base Energy Management Air Force Energy Plan (overview) Air Force Infrastructure Energy Plan (overview) Energy Conservation Projects at Eglin Energy Management System (EMS) – Load Shedding/Peak Demand (RTP)
7
Eglin Air Force Base Energy Management
9
Air Force Energy Plan (overview) Air Force Infrastructure Energy Plan (overview) Energy Conservation Projects at Eglin Energy Management System (EMS) – Load Shedding/Peak Demand (RTP)
10
Eglin Air Force Base Energy Management 33 Major Energy Conservation Measure Projects (2009-2012 ) Total Cost of Projects: $17,259,035 Total Annual Dollar Savings: $3,527,507 (4.8 YR SPB) Total MMBTU Annual Savings: 150,780 MMBTU (million BTU) Projects include: Retrofit Lighting (interior/exterior) Retro Commissioning Chiller Replacements Solar Reflective Roofing Solar Thermal Heating *****Energy Management System (EMS) – Load Shedding/Peak Demand (RTP)******
11
Solar Reflective Roof Building Project Cost $612,000 Projected Savings $61,000 Per Year Project Pay Back 10 Years
12
Base Pool Solar Thermal Hot Water Heat 162- 4x12 Ecosun Solar Thermal collection panels Project Cost $117,326 Current energy & water cost $21,320 Yr Projected cost w/Solar Heating $8,451 Savings per year $12,869
13
Eglin Air Force Base Energy Management Air Force Energy Plan (overview) Air Force Infrastructure Energy Plan (overview) Energy Conservation Projects at Eglin Energy Management System (EMS) – Load Shedding/Peak Demand (RTP) Project Summary/Economic Analysis Results Potential Emission Reductions Goals and Objectives Description of Work
14
Eglin Air Force Base Energy Management Energy Management System (EMS) Load Shedding/Peak Demand (RTP) Pillar 2: Improve Future Infrastructure Meet/exceed mandated energy intensity reduction goals Develop metrics & measurement capabilities to track energy performance of facilities
15
Eglin Air Force Base Energy Management Eglin utilized a Utility Energy Services Contract to implement the Energy Management System project with Gulf Power (electrical utility provider) Chevron Energy Solutions was chosen as the Energy Service Company to implement the project. Chevron developed the proposed upgrade to the existing Direct Digital Controls (DDC) in conjunction with integrating smart metering with the DDC onto a stand alone secure network for proactive management of facility energy consumption – a robust Energy Management System. This energy conservation measure has the potential to reduce the Base’s energy use by approximately 99,000 MMBTU per year to help achieve base energy efficiency goals
16
Eglin Air Force Base Energy Management Project Summary/Economic Analysis Results 100% ECIP Funded 144 facilities chosen
17
Eglin Air Force Base Energy Management Potential Emission Reductions
18
Eglin Air Force Base Energy Management Integrate Utility Metering and Building Controls on a Common IT Platform Comply with Air Force IT Security Requirements Provisions for Future Connection to Other Systems (Fire Alarm, Lighting Controls, SCADA, etc.) Proactive Energy Management to Exceed Goals Goals and Objectives
19
Eglin Air Force Base Energy Management Description of Work Stand‐Alone EMS Network New Building Level Controllers Energy Saving Controls Utility Metering System Interface Data Integration Energy Mgmt. Software/Dashboards
20
Eglin Air Force Base Energy Management Energy Comfort Data Database Dashboards Energy Management Software and User interface/Dashboard
21
Eglin Air Force Base Energy Management
22
Historical Data Real Time Data
23
Eglin Air Force Base Energy Management
24
Data BMS & Energy Analytics Dashboards
25
Eglin Air Force Base Energy Management Brian Gilmore Senior Integrations Specialist Automation and Controls Solutions Mobile #678-300-2666 brian.gilmore@mckenneys.com Brian Gilmore Senior Integrations Specialist Automation and Controls Solutions Mobile #678-300-2666 brian.gilmore@mckenneys.com Fred Gordy Lead Integrations Analyst Automation and Controls Solutions Mobile # 678-296-6499 fred.gordy@mckenneys.com Fred Gordy Lead Integrations Analyst Automation and Controls Solutions Mobile # 678-296-6499 fred.gordy@mckenneys.com For more information and a live demonstration contact:
26
Eglin Air Force Base Energy Management Air Force Energy Plan (overview) Air Force Infrastructure Energy Plan (overview) Energy Conservation Projects at Eglin Energy Management System (EMS) – Load Shedding/Peak Demand (RTP) Project Summary/Economic Analysis Results Potential Emission Reductions Goals and Objectives Description of Work Summary
27
References Websites: https://www.safie.hq.af.mil http://www1.eere.energy.gov http://www1.eere.energy.gov/femp http://www.chevronenergy.com http://www.mckennys.com
28
Eglin Air Force Base Energy Management Questions
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.