Download presentation
Presentation is loading. Please wait.
Published byPhyllis Strickland Modified over 9 years ago
1
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title
2
Copyright 2008 Hach Ultra Analytics – Page 2 MET ONE 7000 Series
3
Copyright 2008 Hach Ultra Analytics – Page 3 Agenda MET ONE 7000 Series Overview Features and Benefits Part Numbers
4
Copyright 2008 Hach Ultra Analytics – Page 4 Introduction to the MET ONE 7000 Series 1.Designed for ISO 21501 compliance, ensures confidence in data accuracy, reliability and repeatability. 2.Flexible communication options and easy installation features allow easy integration of the remote counter with any FMS system. 3.The counter offers the most advanced instrument status and user notification indication feature available in the industry, saving troubleshooting and downtime related costs work. The MET ONE 7000 Series remote airborne particle counters, designed for ISO 21501 compliance, offers accurate, reliable, consistent and repeatable continuous particle monitoring. With a sensitivity range of 0.3 to 10 µm, the MET ONE 7000 Series is designed to meet the specific needs of cleanroom operations within the aseptic or sterile manufacturing facilities in the Life Science industry.
5
Copyright 2008 Hach Ultra Analytics – Page 5 Introduction to MET ONE 7000 Series Service port for instrument set-up Also can be used for optional remote display unit (future enhancement) Optional Relative Humidity- Temperature probe connection Optional remote indicator light port Multi-color status indicator LED ISO 21501 compliant design Multiple I/O option Built-in enhanced instrument status and user notification indicator Long Life Laser™ VHP tolerant flow path and optics Wall plate, umbilical cords and tubes with quick connect fittings for ease of installation and removal Up to 1000 sampling data storage 0.3 µm sensitivity, 0.1 or 1.0 cfm flow rate Built-in flow sensor option Remote status indicator light option Standard 2 channel, optional 4 channel Sealed enclosure with sealed connectors RH-Temp probe option Free set-up utility program
6
Copyright 2008 Hach Ultra Analytics – Page 6 First Counter Designed With ISO 21501 Compliant Capabilities ISO 21501 is a new calibration standard replacing ASTM F328 and other similar existing standards Accuracy in counting specific particle size Significantly improved measurement repeatability from counter to counter Reliability in accurate identification of particle sizes of interest that affect product quality and yield
7
Copyright 2008 Hach Ultra Analytics – Page 7 Flexible Communication Options Save FMS integration costs, repair and inventory related costs with multiple communications Serial I/O (RS-485 with Modbus RTU or FX protocol) Ethernet Analog Wireless RJ 45 sealed connector for Ethernet, RS485 serial or Analog I/O Makes integration to any FMS easier
8
Copyright 2008 Hach Ultra Analytics – Page 8 Ease of Installation Features Easy installation with AC or DC input power options –100~230 VAC 50/60 Hz house power –24 VDC local power network Reduces re-installation time during routine calibration and maintenance with DIP switch feature for serial units Quick-connect type sealed vacuum connection AC or DC input power option Makes installation easier DIP switch for setting address of RS485 serial I/O instrument Makes installation and removal easier Quick connect type vacuum connector For ease of installation
9
Copyright 2008 Hach Ultra Analytics – Page 9 Ease of Installation Features Wall plate for terminating end-user cables and tubing, reduces disruption to connectivity during routine calibration Umbilical with quick connect sealed connectors protect counter from wash down and make reinstallation easy Quick-connect type sealed vacuum connection makes reinstallation during routine calibration easy User terminates wiring, tubing at the rear end of the wall plate Makes installation easier Umbilical cords and tubing supplied to connect the counter with wall plate For ease of installation and subsequent removal for routine calibration and maintenance. Ensure sealed connections Wall Plate - Front Makes installation and removal of counter easier
10
Copyright 2008 Hach Ultra Analytics – Page 10 Installation Features - Standard Accessories Item Number Description 1MET ONE 7000 Counter 2Mounting Plate 3, 4Isokinetic Probe (0.1 or 1.0 cfm) 5Wall Plate 6Communication Cable with Sealed RJ-45 Connectors 7Power Cable AC or DC 8Vacuum Tubing with Sealed Quick Connectors Reduces initial installation time Minimizes removal and re-installation time during routine calibration and maintenance Provides wash-down tolerance with sealed umbilical and tubing
11
Copyright 2008 Hach Ultra Analytics – Page 11 Enhanced Instrument Diagnostics Instrument can be diagnosed for flow, sensor, communication failures, and count alarm or count alert through built-in or external light indicator Steady Green = Normal (set by software or internal) Flashing Red = Count Alarm (set by software or internal) Flashing Yellow = Count Alert (set by software only) One short flash, one long flash Blue = Flow Fail (set by software or internal) Solid Blue = Sensor Fail (set by software or internal) Flashing Blue (2 Hz) = Communication Failure (internally set based on communication timeout) Enhanced instrument status indication reduce troubleshooting time and downtime Built in or optional remote multi-color status indicator LED
12
Copyright 2008 Hach Ultra Analytics – Page 12 MET ONE 7000 Series Setup Utility Program Reduce set-up time with the MET ONE 7000 Series setup utility program –Local Setup –LAN Setup –Data Display Reduce troubleshooting time –Run MET ONE 7000 Series remote counters without FMS software for troubleshooting –Obtain instrument information such as model, serial number and built in flow sensor
13
Copyright 2008 Hach Ultra Analytics – Page 13 Local Setup Screen Capture
14
Copyright 2008 Hach Ultra Analytics – Page 14 LAN Setup Screen Capture
15
Copyright 2008 Hach Ultra Analytics – Page 15 Data Display Screen Capture
16
Copyright 2008 Hach Ultra Analytics – Page 16 MET ONE 7000 Feature Summary FeaturesBenefits Designed for ISO 21501 calibration capability Counter calibrated per ISO 21501 requirements measures particles accurately, reliably and consistently Flexible communication options Easy to integrate with any FMS system due to flexible communication features such as Serial Modbus, Ethernet Analog and Wireless, and optional OPC server feature Enhanced instrument status and user notification indicator Additional status indications provide faster troubleshooting and reduces downtime Long Life Laser Average ~10 years – reduces cost of ownership Ease of installation, removal and interchangeability Shorter installation time and flexibility for removal and replacement of counters for routine calibration work Sealed enclosure and sealed connectors Provides better sealing for use in wash-down areas Flow Path and optics are VHP tolerant Counter will not be damaged by accidental inclusion of VHP in the sensor flow path during disinfecting process Increased data storage No loss of data during accidental communication or computer problem Hach Ultra MET ONE Brand Quality, performance and service
17
Copyright 2008 Hach Ultra Analytics – Page 17 MET ONE 7000 Series Monetization Reliability in accurate identification of particles due to ISO 21501 compliant design that improves product quality and yield Reduced troubleshooting time (labor), and less downtime Standardized sensor irrespective of communication systems saving integration cost, repair time, downtime and inventory related costs Reduced replacement parts cost and lower overall cost of ownership Reduced removal and re-installation cost during routine calibration/maintenance work Reduced risk of data loss due to communication disruption Please use the monetization tab in the value selling document
18
Copyright 2008 Hach Ultra Analytics – Page 18 MET ONE 7000 Series Part Numbers How to Order
19
Copyright 2008 Hach Ultra Analytics – Page 19 Standard Shipment Includes Item Number Description 1MET ONE 7000 Counter 2Mounting Plate 3, 4Isokinetic Probe (0.1 or 1.0 cfm) 5Wall Plate 6Communication Cable with Sealed RJ-45 Connectors 7Power Cable AC or DC 8Vacuum Tubing with Sealed Quick Connectors
20
Copyright 2008 Hach Ultra Analytics – Page 20 MET ONE 7000 Series
Similar presentations