Presentation is loading. Please wait.

Low Voltage AC, DC, PoE Power Management Systems.

Similar presentations


Presentation on theme: "Low Voltage AC, DC, PoE Power Management Systems."— Presentation transcript:

1 Low Voltage AC, DC, PoE Power Management Systems

2 Innovative US manufacturer with extensive portfolio of smart, low voltage AC, DC, and PoE power management systems Intelligence - IP addressable power systems - Power health monitoring and reporting - Smart battery charging to extend battery life About LifeSafety Power… Industry Firsts Customer-first philosophy - Product modularity/scalability reduces field inventory significantly - Easily expandable customize a system to the job requirements - Factory pre-wiring minimizes tech labor, speeds installation time, increases reliability - Lifetime warranty, advanced replacement customer first philosophy Power systems that increase profits and generate RMR - Web monitoring and reporting typical service functions performed remotely - Proactive power health management suite of managed diagnostic services can be added to annual maintenance contracts

3 Award Winning Innovation… Same features on every power supply 120VAC 230VAC Full power no derating Multiple Outputs Continuous Resettable Fire Alarm Interface Network Interface Multi-Listed PS Access/Security/CCTV/Fire Every FPO Independent charger longer equipment & battery life

4 US UL 294, Standard for Access Control System Units UL603, Standard for Safety Power Supplies for Use with Burglar-Alarm Systems UL1076, Proprietary Burglar Alarm Units and Systems UL864, Control Units and Accessories for Fire Alarm Systems UL1481, Standard for Power Supplies for Fire-Protective Signaling Systems UL2044, Standard for Safety Commercial Closed-Circuit Television Equipment UL2572, Control and Communications Units for Mass Notification Systems CSFM, California State Fire Marshal Canada ULC S319, Electronic Access Control Systems ULC S318, Power Supplies for Burglar Alarm Systems ULC S527, Standard for Control Units for Fire Alarm Systems CSA, Canadian Standards Association Ontario Electrical Safety Authority (ESA) FLEXPOWER Listings Use the same power supply for Access, Fire, Security, CCTV, Mass Notification

5 The “Building Blocks” PoE Power Supplies AC Transformers Smart Management Distribution Modular Portfolio

6 CCTV 8 – 16 POE+ Midspans 100 – 900VA 8 to 96 outputs wallmount 8 – 24 outputs rackmount Access control 2, 4, 8, 12, 16 or more doors… single, dual, or multi voltage up to 20A/12V, 10A/24V Network monitoring options wallmount / rackmount (16) Security - DC Up to 20A@12V 8 to 48 distribution wallmount 8 – 16 rackmount PoE 8 – 16 POE+ Midspans Singleport injector / extractor Modularity Provides Multiple Options

7 FPO150 (150W 12A/12V, 6A/24V) (AL600, AL1012) FPO250 ( 250W 20A/12V, 10A/24V) (AL1024) FPO25 (25W 2A/12V, 1A/24V) (AL300) FPO75 (75W 6A/12V, 3A/24V) (AL400)  Two board footprints.. four power levels.. same features  Part number = Power delivered  Current doubles at 12V setting  Dual outputs / 2A Charger  IP Ready  Multi-listed Power Supplies

8 Accessory Options NL2 Two port network communication M8 / M8P Requires NL4 SMART MANAGEMENT NL4 Four port network communication B100 adjustable DC-DC 5 – 18VDC@4A SECONDARY VOLTAGE DISTRIBUTION MODULES D8 / D8P (PD8) C4 / C4P (ACM4) C8 / C8P (ACM8) F8 / F8P (MOM5) PN Decoding C = Control D = Distribution F = FAI 4/8= outputs P = PTC style

9 Enclosure Options

10 Part Number Builds Your System

11 Quick Pick Guide - 4/8 Door Access EQ Cost <$145 FPO75-E1 6A/12V PS/enclosure  On board FAI, 1A micro charging circuit, dual outputs  110/230VAC, Multi-listed  IP ready with optional network module  Listed to all standards EQ Cost <$280 FPO75/150 vs AL400ULX & AL600ULX  One enclosure vs two  One conduit drop vs two  Less wall space  Easy to expand with accessories  IP ready… and more  Listed to all standards INDUSTRY COMPARISON

12  Saves wall space, installation time, system cost 4 Door Access Access Power two (2) AC drops two (2) enclosures two (2) battery sets Lock Power  One enclosure  One AC drop  One battery set  Pre-wired LSP boards  Order as E2 for larger enclosure FPO75-B100C4E1 2A/12V & 2A/24V  Easy upgrade to remote power management for  Remote service and reporting  Power cycle outputs over the web  Auto test battery condition remotely  Time to service notification

13  Saves wall space, installation cost, system cost  Distribution expansion room FPO150-B100C8E2 4A/12V & 4A/24V  One enclosure  One AC drop  One battery set  Pre-wired LSP boards  Easy upgrade to remote power management 8 Door Access Access Power two (2) AC drops two (2) enclosures two (2) battery sets Lock Power

14  Service system anywhere, instantly … PC, iPad, Smartphone  Customize battery and power management  Set proactive notifications email / SNMP FLEXPOWER managed power UCB Medical Center Garage Level 5 Door Strike (over current) 09:10AM 12/15/13 Battery Service due 12/31/14 45 Park Avenue Center Main Reception /Access Panel #503 AC LOSS 12/19/14 3:43AM AC RESTORE 12/19/14 4:07AM

15 15 UCB Medical Center Garage Level 5 Door Strike (over current) 09:10AM 12/15/14 Battery Service due 12/31/14 45 Park Avenue Center Main Reception /Access Panel #503 AC LOSS 11/19/14 3:43AM AC RESTORE 11/19/14 4:07AM QUICKER RESPONSE, SMARTER DISPATCHING  Power cycle frozen devices remotely - saves on-site service calls  Detect, test and report standby battery health  Review time/date stamped event logs FLEXPOWER managed power

16 … simply smarter power Browser-based  Easy set up  Live – quick access status screen  Configure reporting detail Remote Service – saves time and money!  Set alerts  Diagnose trouble reports  Remote test batteries  Power cycle outputs  Review and capture event log detail PowerCom Monitoring Dashboard

17 Power Supply Dashboard … simply smarter power PowerCom Monitoring Dashboard 17

18 Managed Outputs Dashboard Reports if device voltage or current goes out of spec … simply smarter power PowerCom Monitoring Dashboard 18

19 proactively know when locks or cameras draw outside their rated current …and replace them before they fail Normal Range Notification time √ √ √ SNMP or EMAIL Notification … simply smarter power PowerCom Monitoring Dashboard 19

20 20 IP Video Managed PoE Midspan Injectors  120/230VAC or 48VDC operation  10/100/100Base-T Gigabit support  Built in 48V battery charger for cost effective back-up All units include battery backup & remote monitoring!  Power and data to PoE devices at full 32W/port  Monitor and Manage individual outputs online  View and manage status from any browser across devices  Instant alerts via email / SNMP on output trouble  Remote reset - saves onsite visit just to recycle power!

21 21


Download ppt "Low Voltage AC, DC, PoE Power Management Systems."