Testing of water penetration under pressure – NBR 10.787/94 (April 2007) Cement: CPII-E 32.

Similar presentations


Presentation on theme: "Testing of water penetration under pressure – NBR 10.787/94 (April 2007) Cement: CPII-E 32."— Presentation transcript:

1 Testing of water penetration under pressure – NBR 10.787/94 (April 2007) Cement: CPII-E 32

2 Testing of water penetration under pressure – NBR 10.787/94 (April 2007) Cement: CPII-E 32 Applied water pressure: day 1 to day 2: 0,1MPa day 3:0,3MPa day 4 to day 7:0,7MPa cement content CPII-E 32350kg/m³ design strength20MPa fine aggregate388kg/m³ coarse aggregate 0421kg/m³ coarse aggregate 1632kg/m² water192kg/m³ plasticiser admixture0,3% a 0,4% mc Slump90±10mm W/C ratio0,54 Penetron Admix1% of the cement content

3 Testing of water penetration under pressure – NBR 10.787/94 (April 2007) Cement: CPII-E 32 - 1 week after start of water pressure

4 Testing of water penetration under pressure – NBR 10.787/94 (April 2007) Cement: CPII-E 32 - 2 weeks after start of water pressure

5 Testing of water penetration under pressure – NBR 10.787/94 (April 2007) Cement: CPII-E 32 - 3 weeks after start of water pressure

6 Testing of water penetration under pressure – NBR 10.787/94 (April 2007) Cement: CPII-E 32 - 4 weeks after start of water pressure