C OINS The coin operated binocular / telescope can accept most, though not all,coins into the coin chute. It can be program easily by yourself or you can offer us a sample of coin if needed and we can program it for you. (Acceptable coin size ranging from 20 mm to 30 mm in diameter) Example 1: Coin size 20mm in diameter Example 2: Coin size 30mm in diameter Please check the acceptable coins of your country according to the following website www.digilens.com.tw
5
Type A change to Type B
7
To set a view time between 1 and 3 minutes by adjusting a revolving time switch. 2. The SWITCH To push the SWITCH to test on the coin number setting. 3. The Green/Red LED Display The green LED display will light up to last 5 seconds as soon as the coin selector has accepted the correct coin number put into by the viewer. Once the view time is up, the red LED display will light up to last 5 seconds then go out. The LED display lights up means that the battery still has the electric power and the circuit is normal as well. 4. The State of the Oncoming Exhaustion of the Battery Power The red LED display or the green LED display will be dim and slow in reacting while the battery power is on the verge of using up. In case the battery power is used up during the view, the shutter can not close. At the moment, the battery has to be replaced with new one at once, and please press the SWITCH to reset, then the shutter will close and return to normal operating system once the view time is up. In case the battery power is used up during the close of the shutter, it will have no reaction after the viewer put the coin into. At the moment, the battery has to be replaced with new one at once, and it will return to normal operating system once the viewer put the coin into once again. 5. How to Connect the Wiring with the Binoculars Please properly connect “the male connector of the power cord of the circuit board” with “the female connector of the power cord of the binoculars”, with corresponding same color power cord, on a basis of white-white & black-black. In case of the wiring in reverse of white cord to black cord, contrary to normal reaction, the shutter will close after the viewer put into the coin required, contrariwise the shutter will open after the view time is up. At the moment, please exchange the wiring to be correct as white-white & black-black. 1.Time setting
8
Breakdown factor inspection and trouble shooting 1.General breakdown factor ※ There are foreign particles in the coin throwing hole, cannot throw and withdraw the coin / Clean the foreign particles ※ The battery is run out of electricity / Replace the battery ※ The circuit cable is dropped / Connect the circuit cable ※ Switch breakdown / Replace the switch ※ Not-fitting sized coin stuck / Press withdraw button to draw back the coin 2.Special breakdown factor ※ Circuit board breakdown / Replace circuit board ※ Protection glasses of object lens or eye lens are destroyed / Take picture and inform damage situation ※ The main body of telescope is destroyed / Take picture and briefly describe the damage situation The following describes the breakdown situation occurs usually and its treatment 1. Cannot throw the coin Treatment: Open the throwing coin door, check if the foreign particles are stuck in the coin chute or the coin gets stuck. Clean the foreign particles or take out the coin. If the coin chute is too big, adjust and fix 2 screws of the coin chute to fit the coin diameter. Simple trouble shooting
9
Check the circuit box, if the connection cable to the telescope is dropped. Yes. Re-connect the circuit cable. Ok. No: Check if he battery is run out of electricity. No. Open water-proof box; check if the circuit cable is dropped. Yes. Replace battery. Ok. No. Press SWITCH and check if CV03 green light of circuit board is on. Yes, Re-connect the circuit cable. Ok. Yes, Test the connection cable at the telescope end with battery and check if the motor is damaged. No. Check if Switch is breakdown, check if circuit is breakdown. After throwing the coin, the shutter remains close, cannot watch. Or not throw the coin, but the shutter remains open. 2. After throwing the coin,the shutter remains close, cannot watch. Or not throw the coin, but the shutter remains open. Treatment:
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.