1
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Slide 1 GOSSAMER COVE Redwood City, CA Illustrated Preliminary Defect List Presented By: R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 3550 Camino Del Rio North, Suite 305 San Diego, CA 92108 (619) 624-9272 FAX (619) 624-9566 www.rhadcock.com
2
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Overall
3
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Overall
4
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 1.0 ROOFS Composition Shingle
5
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Degradation and tears in composition shingles.
6
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Leaks at complex intersections of roof.
7
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Shingle installed upside down.
8
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Metal flashing laps not sealed.
9
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Headwall flashing nailed through.
10
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Discontinuous edge metal at outside corners.
11
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Gaps in flashing.
12
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Cracked shadow board.
13
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Gutter system lifting shingles at eave.
14
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Penetration flashings not set in mastic.
15
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Penetration flashings not set in mastic.
16
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 2.0 BALCONIES
17
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Balcony Overall
18
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Balcony waterproofing system failure; staining and water intrusion.
19
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Ponding at balcony/inadequate slope.
20
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 5.0 EXTERIOR SIDING AND TRIM
21
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Exterior siding fasteners popping and overdriven.
22
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Exterior siding fasteners popping and overdriven.
23
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Missing sealant at joints in siding.
24
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Voids at penetrations.
25
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Water table flashing nailed through.
26
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Damaged siding installed.
27
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Exterior light fixture not sealed.
28
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Gaps and separation at wood trim.
29
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Gaps and separation at wood trim.
30
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Improper flashing termination at brick veneer; exposed building paper.
31
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Garage door wood trim in contact with concrete.
32
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 8.0EXTERIOR DOORS
33
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. French door threshold failure; stained tack strip and missing sealant.
34
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. French door sticking/racked.
35
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Failed glazing strips at door exterior; leaking sealant.
36
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Improper door weather strip; gaps.
37
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 9.0CONCRETE
38
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Concrete slab failure at garages/ponding and spalling.
39
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Concrete flatwork failure at driveway; cracking.
40
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Efflorescence at slab.
41
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Driveway with reverse slope to garage/ponding.
42
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Driveway slab with vertical displacement.
43
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 11.0 WALLBOARD
44
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Drywall system failure; cracking.
45
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Drywall system failure; cracking.
46
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Wallboard cracks at doors.
47
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Window sill and jamb drywall cracking.
48
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 14.0 SUB-FLOORS
49
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Floor sheathing is improperly fastened; floor squeaks.
50
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 15.0MISCELLANEOUS ARCHITECTURAL
51
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Failure of rigid grout at counter tops to backsplash in kitchens; cracking.
52
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Kitchen ceramic tile failure; cracking.
53
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Laundry room ceramic tile failure; cracking.
54
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Bathroom overall.
55
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Bathroom vanity ceramic tile failure; cracking.
56
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Bathtub/fiberglass panel joint failure; leaking.
57
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Inadequately supported bathtub.
58
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Vinyl flooring lifting in front of tub.
59
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Shower enclosure failure; stained.
60
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Shower enclosure failure; stained tack strip carpet.
61
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Shower pan/ceramic tile joint without flexible grout.
62
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Attic access inadequate; less than 30"x 30".
63
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 16.0 VINYL WINDOWS
64
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Window Overall
65
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Window system failure; staining.
66
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Window system failure; staining.
67
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Window system failure; staining.
68
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Vinyl window damaged during installation.
69
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Fogged dual pane window.
70
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Window installed out of square.
71
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 17.0 ELECTRICAL
72
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Ground wires not attached.
73
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. GFI circuit overload easily tripped.
74
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 19.0 PLUMBING
75
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Slab interior leak; requires further investigation.
76
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Improper attachment of toilet.
77
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Plumbing leak at gas water heater.
78
R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. The End