1
Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010
2
Chapter 1 Scope and Administration
3
Recommendation to Add: Preamble Pursuant to 59 O.S. § 1000.23, the Uniform Building Code Commission has adopted the 2009 International Residential Code (“2009 IRC”), as amended and revised by the Commission, as the minimum standards to be used by all entities for residential construction in jurisdictions throughout the State of Oklahoma. However, the Commission’s adoption of Chapter 1 “Scope and Administration” of the 2009 IRC is for continuity purposes only and the Commission’s adoption of Chapter 1 is limited to the Commission’s recognition of best practice in fully implementing the minimum standards for residential construction. All other provisions of the Oklahoma adopted 2009 IRC other than Chapter 1, as amended and revised by the Commission, are hereby established and adopted as the statewide minimum standards for residential building construction in Oklahoma pursuant to 59 O.S. § 1000.23, which may only be amended or altered pursuant to Oklahoma law and the administrative rules of the Oklahoma Uniform Building Code Commission as set forth in Title 748, Chapter 15 of the Oklahoma Administrative Code. The Commission’s limited adoption of Chapter 1 is made with the recognition that the legal authority granting state and local code administration and enforcement jurisdictions the power and discretion to administer and enforce codes arises from Oklahoma laws governing those jurisdictions. Furthermore, the Commission also recognizes that many state and local code administration and enforcement jurisdictions have already created, or have the lawful authority to create, departments, offices and administrative policies pursuant to various applicable laws and other adopted model codes with “Scope and Administration” provisions similar Chapter 1 of the 2009 IRC. Accordingly, the provisions of Chapter 1 adopted herein are only intended to be in force and effect to the extent that the respective provisions do not conflict with State law or the lawful exercise of code administration and enforcement jurisdiction by entities empowered to do so pursuant to applicable law. Additionally, it is the intent of the Uniform Building Code Commission that the adoption of Chapter 1 shall create no positive or greater duties, responsibilities or obligations to code administration and enforcement jurisdictions other than those which already exist or hereafter arise as a matter of state or local law.. Vote: 100% For
4
Chapter 2 Definitions
5
Chap 2 Adopt: Vote: 100% For
6
Chapter 3 Building Plans
7
R302.1 Modify: - Fire-resistant construction, exterior walls Revise table R302.1 for minimum fire seperation distance for walls and projections from walls <5ft …… <3 ft. Projections ≥ 2 ft to 5 ft ….. ≥ 2 ft to 3 ft Vote: 100% For
8
R310.1.1 Modify: - Emergency escape and rescue openings, minimum opening area Revise minimum clear opening from 5.7 sq ft to 5.0 sq ft Ground level and elevated openings will now be equivalent. Vote: 100% For
9
R311.7.4.1 Amend: -Stairway riser height Stairs to have risers within 3/8” variance at rough-in. Top and bottom riser may vary by ¾” at final inspection. Vote: 100% For
10
R313.2 and R313.2.1 Move to the Appendix: R313.2 One and two family dwelling automatic fire systems R313.2.1 Design and Installation Vote: 100% For
11
R315.1 Add Exception: -Carbon Monoxide alarms Exception #1 Residences with attached garages and: 1) sealed door between the residence and the garage, and 2) no fuel burning devices in the garage then carbon monoxide detection is not required within the residence. Vote: 8 For 1 Against
12
R323 Remove from the code: - Storm shelters Remove “In addition to other applicable requirements in this code, storm shelters shall be constructed in accordance with ICC/NSSA 500” Vote: 100% For
13
Chapter 4 Foundations
14
R402.2 Add: Materials - Concrete Exception #1 Interior concrete slabs on grade and enclosed garage slabs are not required to be air entrained. Vote: 100% For
15
R406.2 Add: -Concrete and Masonry foundation waterproofing Add the following to the list of approved materials #8 Bentonite Vote: 100% For
16
Chapter 5 Floors
17
R506.2.3 Add: -Vapor Retarder “..or other industry accepted vapor retarder products per manufacturers specifications” Vote: 100% For
18
Chapter 6 Wall Construction
19
R602.4 Add: -Interior load-bearing walls “Per the commentary this section is limited to stud spacing and height per Table R602.3(5) and Table R602.3(1) Vote: 100% For
20
R602.10.6 Add: -Braced wall panel connections Exception #4 Wood sole plates of braced wall panels at building interiors on monolithic slabs may be anchored using connector(s) with a shear capacity of 2300 lbs and a tensile capacity of 800 lbs over a maximum span of 6 feet. Vote: 100% For
21
Chapter 7 Wall Covering
22
R703.8 Add: -Flashing” “6 mil visqueen is an approved corrosion resistant flashing when not exposed to UV light” Vote: 100% For
23
Chapter 8 Roof-Ceiling Construction
24
R801.3 Remove from the code: -Roof drainage “In areas where expansive or collapsible soils are known to exist, all dwellings shall have a controlled method of water disposal from roofs that will collect and discharge roof drainage to the ground surface at least 5 feet from foundation walls or and approved drainage system” Vote: 100% For
25
R802.3 Add: -Framing Details “Definition of a brace – 1) a triangular configuration of framing members with a horizontal tie or rafter, 2) King post or similar” Vote: 100% For
26
R802.3 Add: Vote: 100% For
27
R802.5.1 Add: -Purlins “2x6 braces on 6 ft centers may be accepted in place of the 2x4 braces on 4 ft centers” Vote: 100% For
28
Chapter 9 Roof Assemblies No Changes
29
Chapter 10 Chimneys and Fireplaces No Changes
30
Chapter 11 Energy Efficiency
31
R1101.9 Move to Appendix: - Certificate Vote: 100% For
32
R1102.4.3 Remove from the code: -Air leakage, Fireplaces Remove all mention of “gasketed doors” from this section of the code. Vote: 100% For
33
R1103.1.1 Remove from the code: - Programmable thermostat Vote: 100% For
34
R1103.2.2 Add: -Duct Sealing “visual inspection may be used instead of the roughin test and the post construction test” Vote: 100% For
35
R1103.8.3 Remove from the code: -Pool covers Remove first sentence of this section “Heated pools shall be equipped with a vapor retardant pool cover on or at the water surface.” Vote: 100% For
36
R1104.1 Add: -Lighting Equipment Exception #1 Can or recessed lights are exempt from this section of the code Vote: 100% For