Download presentation
Presentation is loading. Please wait.
Published byIrma Rich Modified over 9 years ago
1
M&B TM 1998 Ford Escort
2
Ford ECT ECT
4
KOEO ECT Disconnected ECT Voltage= 4.75V ECT Temperature= 61F
5
KOEO Jumper Across ECT ECT Voltage=.01V ECT Temperature= 61F
6
KOER At Operating Temperature ECT Voltage=.66V ECT Temperature= 192F
7
KOER At Operating Temperature ECT Disconnected- car still running ECT Voltage= 4.75V ECT Temperature= 199F and climbing Cooling Fan On as soon as ECT was Disconnected
8
KOER At Operating Temperature Jumper Across ECT- car still running ECT Voltage=.01V ECT Temperature= 210 and climbing Cooling Fan on as soon as ECT was Jumped
9
KOEO at Operating Temperature ECT Disconnected until Max Temperature was achieved ECT Temperature stopped at 219F
10
KOER at Operating Temperature ECT Plugged Back In Cooling Fan Switched Off ECT Voltage=.73V ECT Temperature= 183F