UR24 Process Refractometer
2
UR24 Refractometer
3
UR24 - Optical Path 85 Brix 10 Brix 0 Brix 1 - LED SOURCE
3 4 5 6 1 - LED SOURCE 2 - BICONVEX LENS 3 - ENTRANCE LENS 4 - PRISM 5 - EXIT LENS 6 - CCD DETECTOR 85 Brix 10 Brix 0 Brix
4
UR24 - The four basic elements
In order to obtain a refractometric measure need four basic elements: A light source (LED source) An optical sensor (CCD sensor) A well defined optic path (lenses and instrument geometry) 4) A prism made in high nD material 2 1
5
UR24 - Interface detection
Threshold Derivative
6
UR24 - Technical features
Measurement limits: 0-95 Bx Measurement range UR24 ST: min 30 Bx, max 95 Bx Accuracy ST version: 0.5% measurement range (+/ Bx) Measurement range UR24 H.A.: min 15 Bx, max 95 Bx Accuracy H.A. version: 0.3% measurement range (+/ Bx) “User” range on request Pt100 external temperature sensor (internal on request) Automatic temperature compensation: -5 °C / 105 °C Long probe version for boule applications and/or high temperature applications (up to 140 °C) Analog output: 0-20, 4-20 mA Serial output: RS422/485 Profibus module on request Washing/Alarm contact Hold measure contact Power supply: 18-36VDC 10W or 12-24VAC 50-60Hz 10VA (AC 115/230V ±10% 50…60Hz 10VA on request)
7
UR24 - Technical features
Sapphire prism Removable prism-holder High efficiency LED light source CCD optical sensor (2048 pixels) Single board SMD electronics Serial port software upgrade Dehydrating cartridge Interfacing with water proof connector LCD graphic display 4-keys polyester membrane keypad 3A enclosure on request Materials in contact with product: AISI316, sapphire/glass (others on request) Working pressure: -1 / 15 bar Weight: 3Kg Enclosure: stainless steel IP67
8
UR24 Standard
9
UR24 Long Probe with Tri-Clamp at 21mm
10
UR24 Long Probe with Tri-Clamp at 70 mm
11
UR24 Adaptors
12
UR24 - Installation examples
on line by pass
13
UR24 - Installation examples
pump on boule
14
Each product has its own optimal speed for prism selfcleaning
UR24 - Special plug for selfcleaning Each product has its own optimal speed for prism selfcleaning Changing the clearance height allows to have the optimal cleaning for each product
15
UR24 - Cleaning systems special plug with mechanical cleaner
special plug with washing
16
special plug with mechanical cleaner and washing
UR24 - Cleaning systems washing on tank special plug with mechanical cleaner and washing washing on pipe
17
UR24 - User configuration
Instrument takes into account typical behaviour for nD % weight/weight nD 16 8 25 33 42 50 1,33 1,38 nD - concentration nD - temperature nD 1,30 1,40 10 20 30 T (°C) 20% in water Default configuration: sucrose solution curves
18
UR24 - User configuration
1st STEP: at 20°C fixed temperature find the relationship between the concentration and the refraction index. 2nd STEP: at fixed concentration find the relationship between the corrections, you have to add to the 20°C value and the temperature Product sample 3rd STEP: transfer data in the UR24 refractometric unit Termostating Unit
19
REFRACTION INDEX-CONCENTRATION configuration
UR24 - User configuration REFRACTION INDEX-CONCENTRATION configuration Found the relationship between concentration and nD at seven different values of concentration at 20 °C for desired product
20
TEMPERATURE COMPENSATION configuration
UR24 - User configuration TEMPERATURE COMPENSATION configuration Measuring the refractive index at three different concentrations at three different temperatures, insert the errors in temperature table (difference between read values of each concentration at that temperature and at 20°C)