Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee September 28, 2011 Mira Vowles, P.E., CEM Emerging Technology Project Manager BPA Energy Efficiency
2
Slide 2 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pumps (VC HP = VRF + DHP) + Ductless Heat Pumps Variable Refrigerant Flow Heat Pump System
3
Slide 3 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N SCE Upstream VRF Program Summary Started in 2010 Distributers receive incentives Energy Solutions administers program
4
Slide 4 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Upstream VRF Program Discussion Jeff Johnston, LEED AP Energy Solutions Project Manager
5
Slide 5 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Small Office VRF Savings Summary VRF HP Measure # Baseline SystemLocation (TMY)(kWh / ton) Gas Heat Offset (Therms / ton) Therm Savings ($) 1 Small Office ASHRAE System #3 (Packaged single zone AC with gas heat) Seattle1,46415$15 2 Small Office ASHRAE System #3 (Packaged single zone AC with gas heat) Spokane1,28842$42 3 Small Office ASHRAE System #4 (Packaged single zone heat pump) Seattle1,6510$0 4 Small Office ASHRAE System #4 (Packaged single zone heat pump) Spokane1,8880$0 Average 1,573 kWh
6
Slide 6 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Medium Office VRF Savings Summary VRF HP Measure # Baseline SystemLocation (TMY)(kWh / ton) Gas Heat Offset (Therms / ton) Therm Savings ($) 5 Medium Office ASHRAE System #5 (Packaged VAV with gas boiler reheat) Seattle62068$68 6 Medium Office ASHRAE System #5 (Packaged VAV with gas boiler reheat) Spokane45359$59 7 Medium Office ASHRAE System #6 (Packaged VAV with electric reheat) Seattle1,5960$0 8 Medium Office ASHRAE System #6 (Packaged VAV with electric reheat) Spokane1,8080$0 Average 1,119 kWh
7
Slide 7 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Small Office VRF Cost Effectiveness VRF HP Measure # Baseline System Location (TMY) Incr. Cost ($ / ton) BCR SPB (years) BPA Incentive ($) % Savings 1 Small Office ASHRAE System #3 (Packaged single zone AC with gas heat) Seattle8353.18$31962.5% 2 Small Office ASHRAE System #3 (Packaged single zone AC with gas heat) Spokane8353.19$28151.3% 3 Small Office ASHRAE System #4 (Packaged single zone heat pump) Seattle8603.17$36065.3% 4 Small Office ASHRAE System #4 (Packaged single zone heat pump) Spokane8603.67$41260.7% Average BCR 3.2 $343 60%
8
Slide 8 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Medium Office VRF Savings Summary VRF HP Measure # Baseline System Location (TMY) Incr. Cost ($ / ton) BCR SPB (years) BPA Incentive ($) % Savings 5 Medium Office ASHRAE System #5 (Packaged VAV with gas boiler reheat) Seattle5403.43$13534.9% 6 Medium Office ASHRAE System #5 (Packaged VAV with gas boiler reheat) Spokane5402.63$9925.0% 7 Medium Office ASHRAE System #6 (Packaged VAV with electric reheat) Seattle5404.85$34831.5% 8 Medium Office ASHRAE System #6 (Packaged VAV with electric reheat) Spokane5405.56$37842.5% Average BCR 4.1 $240 33%
9
Slide 9 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N VRF Program Research Questions Can whole building regression analysis be used to verify savings? How can savings associated with changes to ventilation systems be verified cost- effectively? How big of an effect do other baselines have on savings? Other?
10
Slide 10 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N VRF Program Delivery Questions Can this be a utility equipment rebate program, instead of an upstream program? Limit to replacement on burn-out? How to ensure replacement on burn-out? Limit to baseline systems? How to ensure baseline systems? Other?