Presentation is loading. Please wait.

Presentation is loading. Please wait.

MuTr Recapacitation RIKEN/RBRC Itaru Nakagawa 中川格 1.

Similar presentations


Presentation on theme: "MuTr Recapacitation RIKEN/RBRC Itaru Nakagawa 中川格 1."— Presentation transcript:

1 MuTr Recapacitation RIKEN/RBRC Itaru Nakagawa 中川格 1

2 MuTr Cross Talk 2 HV (1800 V) 1 M  Anode wire 1 M  100 pF.... Cathode strips (96 strip) Rise time of anode signal ~ 10 nsec Removed to reduce HV trips Anode Readout 100mV 3V3V 3V3V

3 3 Pedestal – ADC(3) MIP Hit distribution (200 GeV, zerosup OFF) Strip Gap 1 Stereo Gap 2 Stereo Gap 3 Stereo Gap 1 NonStereo Gap 2 NonStereo Gap 3 NonStereo

4 4 ~15BCLK 12 〜 13BCLK ミューオントリガーヒットレート ビームクロック

5 放置できない理由 5 x2 (Run 11?)x5 (design) Current set up Recap (1/10? cross talk) Luminosity Rate per strip (kHz) Recapacitation + Neutron Absorber + Shaper Tune Run 9, 500 GeV data 10  s 100kHz でパイルアップ!

6 Anode circuit diagram after recap+termination 6 HV (1800 V) 1 M  Anode wire 100 pF.... Cathode strips (96 strip) ~0.1 pF/strip Rise time of anode signal ~ 10 nsec Cathode impedance = 1/  C Z(cathode) = 1/(100 M Hz/ 2 pi * 0.1 pF) = 6 k  @10 nsec Z(bypass) = 6  << Z(cathode) R<<1M  1 M  Recap Terminator

7 All capacitors are removed. New capacitors will be soldered and attach terminators to ground. All capacitors are removed. New capacitors will be soldered and attach terminators to ground. Recapacitation (Station-1) terminator capacitors 2010: Gap-1 2011?: Take Station-1 Chamber out, and solder 2010: Gap-1 2011?: Take Station-1 Chamber out, and solder 7

8 Recapacitation (Station-2) terminator Capacitors are remaining. So new terminal cards to be mounted to the anode readout connector. Capacitors are remaining. So new terminal cards to be mounted to the anode readout connector. 8 terminator

9 Recapacitation (Station-3) All Capacitors had removed. It is very difficult to take out Station-3 chamber. Thus “clamp type” recap-board is under development. All Capacitors had removed. It is very difficult to take out Station-3 chamber. Thus “clamp type” recap-board is under development. 9

10 Installation Constraint 10

11 North Station-3 Anode Gap 11

12 North Station-3 Anode Gap 12 50mm

13 North Station-3 Anode Gap 13 25mm 28mm Cross section drawing

14 Surface Coating Anode Card Parylene C Print Kote remover Takes time, but eventually comes off Will melt with chloronaphthalene at 175 degrees (more than 1 hour). Practically impossible Perhaps parylene coating may be partially comes off when De-Capacitation was attempted 14

15 Clamp Conceptual Design Probe 15 Gap-1 Station-3 Anode Card Clip holder Station-3 Chamber Capacitor Pad Gap-2 Station-3 Anode Card 28mm MuID SideInstall side

16 History of R&D Spring Sprint Probe Probe Length > ~few cm Max Current < 3A Spring is not too strong Probe Length > ~few cm Max Current < 3A Spring is not too strong NG Possibly penetrate coating Good 16

17 17 St-1 Recapacitation Clip Prototype Delivered in mid. February. To be tested shortly.

18 History of R&D Force crown to contact with pad G10 Due to the warp, crown probe contact on pad with only single point. warp=300um 18 Looses it’s contact if adjacent pad have left over solder.

19 History of R&D Absorb any surface structure of pads by separating each channels with slit Confirmed good contact even strips right next to the channel where 800um high left over solder is Left over solder 19

20 History of R&D Register<6m  Thickness is limitted <500um 20

21 History of R&D Flammability Registance Fuji RubberUL94-V2 2〜32〜3 Shin’Etsu Rubber UL94-V0 100〜40 0  21

22 Recap Effect 22

23 Test Bench Setup 90Sr Source Anode wire Cathode Strip # 22 23

24 Oscillo Snap Shot (w/o Recap) 22 27 17 10 sec accumulation time Trigger Source @ 21 ~ 22 Strip# No Recap 24

25 With Recap 22 27 17 10 sec accumulation time Trigger Source @ 21 ~ 22 With Recap 25

26 10 sec accumulation time Trigger Strip#27 Strip#25 Strip#20 Strip#19 Source @ 21 ~ 22 w/o recap averaged pulse 26

27 Trigger Strip#27 Strip#25 Strip#20 Strip#19 Source @ 21 ~ 22 w/ recap averaged pulse 27

28 Measurement w/ DAQ ADC>1000ch …,13,1431,32,… …21,22,23… 90Sr Source Strip Number ADC [channel] Not sharing Anode wire Not sharing Anode wire Not Sharing Anode wire Not Sharing Anode wire Strips below source 28

29 Comparison w/ vs. w/o Recap w/o Recap w/ Recap Strip Number 平均 ADC [channel] Conductive Rubber 29

30 Comparison w/.vs w/o Recap Folk Type Similar effect can be achieved as long as good contact is secured. 30

31 Some Open Questions 31 1.Asymmetric ADC btwn left and right side of central strip 2.Enhanced Effect of Cross talk towards the last strip of anode wire 3.Peak Strip >  xtalk strip

32 Future Schedule 32 Station-3 Anode gap mockup Optimize Utilities For Installation Optimize Utilities For Installation Install folk/rubber prototypes partially In North Station-3 Install folk/rubber prototypes partially In North Station-3 Full Installaiton after Run11 Full Installaiton after Run11

33 Short Term Schedule End July : Station-3 Gap Mock Up Delivery Beg Aug : Different Capacitor/Resistance Combination (10pF, 56pF, 100pF, 1000pF, 0 , 360 , 1M  ) Mid Aug : Station-3 Anode Card & Clamp Delivery Sept : Station-3 Clamp optimization Oct : Prototype Production Nov : Prototype Installation to N.Station-3 33

34 Back Up Slides 34

35 Station-1 vs. Station-3 Station-1Station-3 Between Anode & adjacent card (chamber) Between Gaps 35 ~12mm 25mm 20mm 28mm

36 Removing Palyrene Coating We may need to give up removing palyrene Coating. We may need to give up removing palyrene Coating. 36

37 Conductive Rubber Type 37

38 38

39 PHENIX HV 治具検討(鍬型) 39

40 Hit distribution (200 GeV, zerosup OFF) 40 Strip Pedestal – ADC(3) South arm, Station 1, Octant 1 Gap 1 Stereo Gap 2 Stereo Gap 3 Stereo Gap 1 NonStereo Gap 2 NonStereo Gap 3 NonStereo

41 41 Pedestal – ADC(3) Hit distribution (200 GeV, zerosup OFF) Strip Gap 1 Stereo Gap 2 Stereo Gap 3 Stereo Gap 1 NonStereo Gap 2 NonStereo Gap 3 NonStereo

42 Current readout diagram 42

43 Dumping to GND with C (100pF) 43

44 Re-capacitation ? 44 decapacitation Re-capacitation