Presentation is loading. Please wait.

Presentation is loading. Please wait.

CERN IT Department CH-1211 Geneva 23 Switzerland t Marcin Blaszczyk, IT-DB Atlas standby database tests February.

Similar presentations


Presentation on theme: "CERN IT Department CH-1211 Geneva 23 Switzerland t Marcin Blaszczyk, IT-DB Atlas standby database tests February."— Presentation transcript:

1 CERN IT Department CH-1211 Geneva 23 Switzerland www.cern.ch/i t Marcin Blaszczyk, IT-DB marcin.blaszczyk@cern.ch Atlas standby database tests February 2011

2 CERN IT Department CH-1211 Geneva 23 Switzerland www.cern.ch/i t 2 Outline  Standby databases for ATLAS  Failover and Switchover  Test of standby switchover – February 17 th 2011  Conclusions

3 CERN IT Department CH-1211 Geneva 23 Switzerland www.cern.ch/i t 3 Standby databases for ATLAS Standby database is a copy of production database that can be used for disaster protection –Dedicated physical standby database for : ATONR database ATLR database ADCR database Redo Transport Read / Write Access

4 CERN IT Department CH-1211 Geneva 23 Switzerland www.cern.ch/i t 4 Standby databases for ATLAS All ATLAS standby databases: –Installed on new hardware provisioned in 2010 Quadcore servers and high-capacity disks –This has increased resources on standby DBs comparing to previous standby setups –Provided good compromise cost/performance in case of switchover operation –Are located in Safehost outside CERN campus –Reduce risk in case of disaster recovery –Asynchronous transport mode (no influence on primary database performance)

5 CERN IT Department CH-1211 Geneva 23 Switzerland www.cern.ch/i t 5 Failover (unscheduled – DB failure) Redo Transport Read / Write Access

6 CERN IT Department CH-1211 Geneva 23 Switzerland www.cern.ch/i t 6 Switchover (scheduled) Redo Transport Read / Write Access

7 CERN IT Department CH-1211 Geneva 23 Switzerland www.cern.ch/i t 7 Why failover? Advantages: –Failover minimizes downtime – it’s faster than full database recovery from backups –no reconfiguration is needed for users and applications Real life scenarios from other LHC experiments : –LHCB online database failover August 2010 Reason: power cut in LHCb pit –CMS offline database failover March 2011 Reason: Electrical issue with storages in CC

8 CERN IT Department CH-1211 Geneva 23 Switzerland www.cern.ch/i t 8 Switchover tests Scenario –Tests performed on ATONR cluster to validate disaster recovery scenario and infrastructure –Coordinated by Luca Canali (IT-DB),Gancho Dimitrov, Florbela Tique Aires Viegas (ATLAS), Rainer Bartoldus (ATLAS Online DB coordinator) –Performed during technical stop on 17 th of February 2011 First phase: –Standby has been opened in read only mode for testing while primary database was running –Several tests performed regarding connectivity checks for online systems Second phase –Full switchover –All applications have been sucessfully reconnected do primary database while working on standby hardware –Switch back to original hardware

9 CERN IT Department CH-1211 Geneva 23 Switzerland www.cern.ch/i t 9 Switchover tests General outcome: –Tests were successful, switchover scenario has been tested and validated –Standby database has been working fine handling production load for around 2 hours after switchover. –We are able to do switchover / failover in ~30 minutes Issues encountered during test: –DNS local caching can caused some client-specific connectivity problems RDB manager restart solves this problem –connection problems encountered for COOL & CORAL reconnecting after switch back to original hardware We believe this was a one-off issue Fixed with a service restart in that particular occurrence

10 CERN IT Department CH-1211 Geneva 23 Switzerland www.cern.ch/i t 10 Conclusions In case of Primary database lost: –It’s feasible to perform a failover in around 30 minutes Determining that failover is the only and best option can be time consuming –Due to asynchronous transport mode transaction lost is possible but limited to seconds –No reconfiguration on client side is needed –Full database access is guaranteed immediately after switchover Global connection descriptors use aliases instead of physical machine names – all changes on DNS level DNS local caching can cause some client-specific connectivity problems, connection checks needed after of Failover / Switchover

11 CERN IT Department CH-1211 Geneva 23 Switzerland www.cern.ch/i t 11 Acknowledgements Luca Canali (IT-DB) http://phydb.web.cern.ch/phydb/

12 CERN IT Department CH-1211 Geneva 23 Switzerland www.cern.ch/i t 12 Q&A Thank You! Questions? phydb.support@cern.ch marcin.blaszczyk@cern.ch luca.canali@cern.ch