Presentation is loading. Please wait.

Presentation is loading. Please wait.

Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1.

Similar presentations


Presentation on theme: "Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1."— Presentation transcript:

1 Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

2 Advanced Architecture  World’s first 40 GHz handheld cable & antenna analyzer = widest frequency coverage  Highest Dynamic Range 110 dB typical  Highest corrected directivity = highest measurement accuracy  The most built-in Waveguide calibration support, 10 bands standard + 4 custom  Full 4 receiver VNA architecture  Will support full reversing S-Parameter measurements (Future VNA Option)  1 Hz frequency resolution across full range of operation, even up to 40 GHz Slide 2 1 MHz to 8, 14, 20, 30, 40 GHz Cable and Antenna Analyzer Highest RF Immunity (+17 dBm) 250 x 177 x 61 mm (10.0 x 7.1 x 2.4 in) <3.0 kg (6.6 lbs)

3 Advanced Architecture  Uses same sampler technology as our premium VectorStar™ VNA models  Instant On from standby mode  Highest RF Immunity +17 dBm  650 us/point measurement speed typical  New efficient circuitry delivers >4 hour battery life  Rugged K(m) connectors on units 20 GHz and above. Easily convert to N(f) type without compromising field ruggedness  Measure long, embedded transmission systems easily with USB Transmission Sensor and USB Extenders Slide 3 Ruggedized K(m) test ports easily and robustly converted to N(f) using 71693-R adapters stands up to rugged field use

4 Easy to use (Integrated Help)  Integrated Help function  System Info Tab displays instrument info, hardware info and software info in one convenient screen  FAQ Tab displays multiple frequently asked questions. Touch any of the desired questions to reveal the answer. Some FAQ answers may include hyperlinks to the built-in User Guide for more detailed information  User Guide Tab provides easy access to the instrument’s full HTML based user guide. No longer need to carry a hardcopy with you in the field Slide 4 Help screen illustrating multiple help selection tabs

5 Easy to use (Easy Guided Calibration)  Easy Guided Calibration  4 step Cal Setup allows you to select from a variety of calibration types, choose the calibration type that best suits your needs  Choose between Coaxial or Waveguide line type and following calibration steps will change accordingly  Select the DUT connector type, photos provide examples of what each connector typically looks like  Once DUT connector type is selected, the selection of built-in calibration kits is narrowed down to models that fit the chosen DUT type Slide 5 S820E Guided Calibration simplifies calibration process, minimizes errors

6 Easy to use (S820D-like Classic Mode)  S820D-like Classic Mode  Mimics the same basic GUI operation as the former S810D/S820D models  Supports 2-Port Cable Loss like the S8X0D series but uses extendable USB sensors instead of basic diode detectors  1-port measurements like the S8X0D models, no Smith Chart, no 1-port phase measurement helps to minimize confusion and reduce errors with new users  Switch to Advanced Mode when comfortable to gain access to more measurement types and more performance enhancing user control features like adjustable IFBW Slide 6 820D-like Classic Mode GUI Similar flow of operation compared to previous S8X0D models

7 Easy to use (All connectors conveniently located on top)  All connectors located on top  Allows instrument to be used while in protective softcase  No need to spend time looking for desired connector  Keeps sides clear for easy handling  Reduces risk of cabling getting caught or snagged on nearby items Slide 7 1. RF Port 16. DC Power Input 2. RF Port 27. Two USB 2.0 Type A ports 3. BNC External Trigger Input8. Ethernet Port 10/100 MB/s 4. BNC External Reference Input 9. 3.5 mm Aux Headphone Jack Output 5. USB Type Mini B

8 Versatile features and options (Advanced Mode)  Advanced Mode (Default)  Additional measurement types like Smith Chart, 1-Port Phase, Transmission (2 port) Transmission (Ext. Sensor)  Dual Display Format  Mix any 2 measurement types  Simultaneously measure RL/VSWR and 2-Port Cable loss using external sensor  Supports different calibration types for each display, EG:Upper trace has standard 1-port OSL calibration, lower trace has 2-Port external sensor transmission calibration Slide 8 820E Advanced Mode Dual Display

9 Versatile features and options (Advanced Mode Continued)  System Function Tool Bar  Provides one-touch access to common system functions like Preset, Save, Help, Screenshot, Mode Selector, Full Screen  User Defined Shortcuts  Quick one-touch access to six favorite user defined shortcuts. Recall favorite setups without having to open Menu screen or File menu  Additional Markers (8 vs 6) and additional marker functions Slide 9 820E Advanced Mode System Function Tool Bar And User Defined Shortcuts

10 Versatile features and options (High Accuracy Power Meter)  Measure True RMS power accurately using Anritsu MA series USB power sensors  As low as ±0.16 dB uncertainty  Supports Inline High Power Measurements with MA24105A  Easily configure upper/lower measurement limits and scale  Displays both dBm and Watts simultaneously  Choose which one you prefer as the main readout  Easily add offsets to correct for external loss/gain  Easily set relative measurements Slide 10 820E-High Accuracy Power Meter

11 Versatile features and options (Standard Features)  3 Year Warranty (1 year on battery)  2-Port Transmission Measurements  2-Port Cable Loss Measurement (requires external USB Sensor)  High Accuracy Power Meter (requires external USB Sensor)  Ethernet 10/100 port  Remote Control/PC File Transfer  3 USB ports (2 Type A, 1 Type mini-B)  Remote Control/PC File transfer  Peripheral device support  Large Internal Memory  Internally store >2000 files  Sweeps, setups, screenshots Slide 11 820E-0720 includes two 71693-R ruggedized adapters as standard accessories

12 Versatile features and options (Standard Features)  Built-in GPS support (requires 2000-1723-R)  10 user selectable languages  Fast preview of stored sweeps  Large 800 x 600 8.4” Easy to read High Resolution TFT Touchscreen  Supports Daylight & Nighttime modes  Touch screen provides efficient GUI and ease of use, with or without gloves  Alphanumeric keyboard  EZ Name Quick Matrix for fast saving  Can lock touch screen and use cursor mode or USB mouse for instrument control Slide 12 820E-0720 includes two 71693-R ruggedized adapters as standard accessories

13 Versatile features and options (Standard Features)  Active Thermal Management  Allows for faster warmup  Provides superior measurement stability  Passes stringent MIL-PRF-28800F Section 4.5.6.3 Explosive Atmosphere Requirement  Increases MTBF and reliability  Hi Capacity Li-Ion field replaceable battery  Extend field operating time by adding a spare optional battery  Hot swappable when externally powered  S820E-0720 model comes standard with two 71693-R ruggedized K(f) to N(f) adapters Slide 13 820E-0720 includes two 71693-R ruggedized adapters as standard accessories

14 Versatile features and options (Standard Features)  easyTest™ Tools  Generate and share measurement script files among multiple users  Display images, work instructions, details  Allows multiple users to achieve consistent results with reduced errors  Saves valuable time in the field  Line Sweep Tools (LST) Software  Edit sweeps, rename, archive  Generate PDF or HTML reports  Convert RL/VSWR to DTF  Convert RL/VSWR to Smith Chart Slide 14 820E-0720 includes two 71693-R ruggedized adapters as standard accessories

15 New accessories supporting S820E (New calibration kits)  New series of high performance coaxial calibration OSL/TOSL kits  Specified across full instrument operating temperature range: -10°C to +55°C. This is an industry leading first  Newly developed and manufactured by Anritsu, not 3 rd party OEM like most competitor’s offerings  Provides unbeatable performance up to 40 GHz.  K type (2.92mm) mechanically compatible with SMA and 3.5mm connectors  1-year recommended calibration cycle Slide 15 OSLX50A-XX, TOSLX50A-XX High performance, full temperature Coaxial Calibration Kits

16 New accessories supporting S820E (New calibration kits)  New series of high performance coaxial calibration OSL/TOSL kits  Male and Female Models with through component have equal electrical length  Each calibration kit comes with its own soft case pouch, and includes hardcopy of technical data sheet  Cal coefficients are built into S820E firmware, just select the model and the analyzer takes care of the rest  Other Anritsu hand held analyzers will support new calibration kits via future firmware updates Slide 16 OSLX50A-XX, TOSLX50A-XX High performance, full temperature Coaxial Calibration Kits

17 New accessories supporting S820E (New Flexible Cables)  New series of 40 GHz high performance phase-stable test port extension cables  Available with Ruggedized K(f) connectors to mate securely to S820E test ports  Available with standard K type connectors  Can be used with Anritsu bench top VNA’s like VectorStar™ and Lightning™  Provides best performance/price ratio  Highly flexible for easy connection and usage  Available in 0.6m and 1.0m lengths Slide 17 14 Series Phase-Stable Flexible Cables

18 New accessories supporting S820E (USB Transmission Sensor)  New SC8268 USB Transmission Sensor  Designed to optimize 2-Port cable loss measurement/2-Port Transmission (Ext. Sensor) measurement  Provides full coverage from 1 MHz to 40 GHz  Delivers most accurate results with lowest uncertainty Slide 18 SC8268 USB Transmission Sensor

19 New accessories supporting S820E (USB Extender + Cat 5e)  New 2000-1717-R USB Extender  Extends USB Sensor up to 85m for measuring 2-Port cable loss on embedded cables, or on any DUT with ends located physically far from each other  Completely passive, requires no additional power source  Use with standard Cat 5e cable available everywhere (Cat 6 recommended for best results)  Use with 2100-28-R Cat 5e cable to extend up to 22.5m or purchase custom length from local cable supplier Slide 19 S820E shown with 2000-1717-R USB Extender and 2100-28-R cable and SC8268 USB Transmission Sensor

20 Microwave Site Master™ S820E Cable/Antenna Analyzer Slide 20 Advanced architecture, Easy to use, Versatile features and options “Site Master: Proven Accuracy and Reliability you can trust”


Download ppt "Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1."

Similar presentations


Ads by Google