Download presentation
Presentation is loading. Please wait.
Published byMarjory Patrick Modified over 9 years ago
1
J.Ye / SMU May 18, 2015 GOL + SoS R & D Work at SMU 1.The Test of the GOL chip. 2.First test on the SoS driver chip and the submission of a dedicated test chip for radiation tests. 3.Test results of the GSE laser and a 10 GHz VCSEL. The SMU group: Wickham Chen, Ping Gui, Andy T. Liu, Ryszard Stroynowski, Annie C. Xiang, John C. Yang, PeiQing Zhu,, Juheng Zhang, Jingbo Ye
2
J.Ye / SMU May 18, 2015 GOL + SoS 1 to 2 Gbps serialisers, why GOL G-Link 1.25 Gbps TLK2501 2.5 Gbps GOL 1.6 Gbps Rad-hard Bi-polar, 2.5 W Rad-soft 360 mW Rad-hard by design, 400 mW LD driver included 23.2×17.2mm 2 ×2.7mm Price: $50/pcs 12.2×12.2mm 2 ×1mm13×13mm 2 ×1.7mm Price: $15/pcs
3
J.Ye / SMU May 18, 2015 GOL + SoS GOL overview GOL overview: Transmission speed Fast: 1.6Gbps, 32 bit@40MHz Slow: 0.8Gbps, 16 bit@40MHz Encoding scheme CIMT (ex: HDMP-1024) 8B/10B (ex: TLK2501) Program interface I2C JTAG Driver Internal laser driver (bias: 1 mA to 55 mA in 0.4 mA steps) 50ohm line driver, minimum 780 mV differential. Good for VCSEL and Edge Emitter. Package: 144 pin fpBGA with 1 mm solder-ball pitch. Dimensions: 13 mm sides, 1.68 mm tall.
4
J.Ye / SMU May 18, 2015 GOL + SoS GOL architecture
5
J.Ye / SMU May 18, 2015 GOL + SoS Previous tests [ Previous tests [ Ref. GOL CERN website ] 1.Total dose effect: 10Mrad (x-ray, 10 KeV peak) at a dose rate of 10.06 Krad(SiO 2 )/min. No current increase after the irradiation. 2.SEU: 60 MeV proton, fluence of 3×10 12 p/cm 2 at a flux of 3×10 8 p/cm 2 sec. No SEU was observed. Requirements: 10 to 100 Mrad and 10 15 to 10 16 p/cm 2 fluence. 3.BER tests in lab: better than 1.3×10 -14. 4.Power consumption: 400 mW.
6
J.Ye / SMU May 18, 2015 GOL + SoS Test of the GOL chip We plan: A complete chip characterizing according to the IEEE Gigabit Ethernet standard. This includes rise/fall times, eye mask test, jitter studies (DJ and RJ at all 4 testing points of the link system, jitter transfer of the GOL), optical power margin (again in the link system). We did this for the G-Link for the LAr optical link. Agilent didn’t provide it in the data sheet. The PLL lock range. Probe the total dose limit to see if it reaches 100 Mrad. Measure SEUs at different flux levels, using 200 MeV proton beams. Gain experience of using this chip, should it be suitable to inner detector upgrade.
7
J.Ye / SMU May 18, 2015 GOL + SoS System block diagram for in lab test Pattern/clock generator with jitter input TP1 TP2 TP3 TP4 PC interface
8
J.Ye / SMU May 18, 2015 GOL + SoS System block diagram for irradiation test FPGA Board Test chip Carrier Board 1 Test Chip Carrier Board 2 Switch Board Picoammeter Prog. V. Source Freq. Counter Power Supply Board DMM GOL Board 1 GOL Board 2 TLK Rx PC USB DIO Card 2 m away from the beamControl Room 37 m away In the beam Flux TLK Rx TTL LVDS GPIB RS232 This design is still in progress and is changing on daily basis.
9
J.Ye / SMU May 18, 2015 GOL + SoS The schedule System design 1 month Schematic capture 1 month PCB layout 1 month Board assembly 3 wk PCB Debug 3 wk FPGA code 1.5 month Lab Test 1 month Labview code 1 month Irradiation Tests 10/1/05 11/1/05 12/1/05 1/15/05 2/15/06 3/1/06 3/31/06 We are here
10
J.Ye / SMU May 18, 2015 GOL + SoS Why SoS There is no guarantee that GOL can withstand ~10 times more radiation than what has been tested. We do not know if more bandwidth would be needed. We are designing a Link-on-Chip ASIC for the LAr upgrade. This chip may be used for the ID upgrade as well. This project has just been started. Here I report on the first irradiation test and the actions we take based on the preliminary result.
11
J.Ye / SMU May 18, 2015 GOL + SoS The Irradiation of one SoS chip A laser driver chip based on 0.5 m SoS technology was irradiated at MGH (230 MeV proton). Total dose: 116 Mrad. Error free at 1.5 krad/sec and up to 17 Mrad. LAr upgrade okay. Observed current increase at very high dose rate.
12
J.Ye / SMU May 18, 2015 GOL + SoS The SoS test chip In CMOS layout, the technique to combat the leakage current is the enclosed layout transistor (ELT) and the guard-ring around the transistors. In SoS, only ELT is needed. We will use the new 0.25 m SoS technology for the LOC design. In order to probe the total dose limit, to check ELT on SoS, and to check layout parameters on design blocks like the PLL, we submitted a dedicated test chip mid October. The test of this chip is in preparation (3 slides back) and the irradiation test is aimed for April 2006.
13
J.Ye / SMU May 18, 2015 GOL + SoS 1)12X9 transistor array, ELT and “standard” layout, NMOS and PMOS with different size.Test layout techniques and rad-hard limit. 2)4 ring oscillators (ELT, “std”, different transistor size). Test SEUs. 3)5 shift Registers (… + various resistors, majority voting). Test SEUs. 4)6 individual gates (ELT and “std”). 5)PLL parts: -Div16 -VCO -PFD 12 X 8 Transistor Array 6 Individual Gates 4 Ring oscillators 5 Shift registers PLL parts The SoS test chip block diagram Many parameters will be measured in lab and in irradiation. The results will guide us in designing of the LOC chip.
14
J.Ye / SMU May 18, 2015 GOL + SoS The SoS test chip layout Transistors array PLL cells CMOS Ring Oscillators Shift Registers Individual gates Resistors Differential Ring Oscillator Majority vote circuitry
15
J.Ye / SMU May 18, 2015 GOL + SoS Looking for E/O devices We also started to look for laser diodes. We tested two surface emitting lasers. One long wavelength and can couple to single mode fiber, one VCSEL. The preliminary results are briefly reported here.
16
J.Ye / SMU May 18, 2015 GOL + SoS Test results on the GSE laser We exposed 12 Grating-outcoupled Surface-Emitting laser (1310 nm) up to 22.3 Mrad at IUCF with 200 MeV proton. The lasers that received 11.4 Mrad total dose still pass 2.5 Gbps eye mask test. Group C Group D 1.8 Mrad Pass. 22.3 Mrad Fail. 5.9 Mrad Pass. 11.4 Mrad Pass.
17
J.Ye / SMU May 18, 2015 GOL + SoS Test results of a 10 GHz VCSEL Preliminary test results on the ULM 10 GHz VCSEL: We irradiated 2 ULM 10 GHz VCSELs at MGH. The VCSEL were biased during irradiation. The total dose received is 116 Mrad. All DC parameters are still within spec after the irradiation. Eye diagram and other AC parameters will be measured soon.
18
J.Ye / SMU May 18, 2015 GOL + SoS Summary The GOL test program has been started and is on track. We designed and submitted a dedicated SoS test chip to check out layout techniques and measure related parameters. The lab and irradiation tests of this chip is in preparation. We have tested the GSE lasers and find them useful in 11 Mrad environment. The GSE lasers can couple to single mode fibers. The results are accepted for publishing by Photonics Technology Letters (PLT). We have identified a 10 GHz VCSLE and preliminary test results show potential in use with 100 Mrad. More tests are on going and more VCSELs will be tested.
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.