Market introduction CellaTemp PA
2
Newest interface technology Latest high-resolution microprocessors Newest sensors New amplifier technology Improved optical properties Improved thermal shock behaviour (PA 10) CellaTemp PA – Technical news
3
Cylinder-shaped housing with M65 screw thread for very easy mounting hight-quality stainless steel housing Bright LED display on the back side (USP) Connector on the back side 2 current output signal freely configurable in many ways one of these output can be configured as an analog control voltage input (USP) 2 gate inputs/outputs can be freely custom-configured CellaTemp PA – Special features
4
Spot Sighting options alternatively: a) through-the-lens - mirror-inverted b) integrated laser spot light c) integrated high dynamic video camera Integrated USB interface 57600 bit/s RS 485 interface for point-to-point or multidrop network in the development New configuration software „CellaView“ usable for parallel operation of up to 30 pyroemters Complete configuration via keypad or PC Multifunctional configuration possibilities CellaTemp PA – Special features
5
Current output 0(4) – 20 mA Beginning and end of measuring range Smoothing function Data storage mode Emissivity / emissivity ratio setting Interface selection Dirty optics detection in the two-colour pyrometer PA 40 CellaTemp PA- Configuration options (1)
6
Sensor output curve correction at 10 data points Sight glass transmittance setting Compensation for extraneous radiation (PA 10/13) Automatic emissivity determination (PA 40) Automatic temperature detection in discontinuous processes On-site user calibration Sequence average value - peak value selectable Laser can be switched on / off CellaTemp PA – Configuration options (2)
7
Control voltage input to offset interfering factors such as extraneous radiation. Extremely wide measuring ranges High resolution temperature detection 0.2 K + 0.03 % of the adjusted measuring range Electronic dirty window check PA 40 Test current to perform diagnostics polarising filter protects the eye against bright target objects (optional accessory) CellaTemp PA – Special features
8
Configuration of the analogue outputs and inputs
9
Configuration of the input and output swichtes
10
PA Connector Pin Assignment
11
Both USB and RS485 interface usable at the same time Employs either RS485 interface for point-to-point communication or USB interface Integrated software for sensor configuration and data communication. Runs under all common operating systems, executable in any language. Parameter settings can be adjusted during running operations Features of the interfaces
12
Focusable interchangeable lenses High optical resolution due to multiple-element lenses Consistently good imaging properties throughout the entire focusing range Corrected for the infrared and visible spectrum Large, high-contrast field of view e.g. 42 ° when used with the wide-angle lens Minimize Size-of-source effect (make CellaTemp PA less sensitive to fluctuating target size or measuring distance) Optical Features
13
Distance range is infinitely adjustable and precise thanks to screw thread Adaptable to supplementary lenses using camera thread Target size diameter as small as Ø 0.3 mm Eyepiece also suitable for users who wear glasses due to broadened intrapupillary distance By using supplementary lenses a myriad numbers of optical solutions are possible Optical Features
14
Through-the-lens sighting tube with target marker Laser spot indicator Video camera Viewing options
15
CellaTemp PA with video camera
16
Wide measuring ranges Consistently high resolution throughout the measuring range Low quantisation noise, even at the lower end of the measuring range Sensor and Signal Processing
17
Type overview (1) – One colour compact pyrometer
18
Type overview (2) – Two colour compact pyrometer
19
Type overview (3) – One colour fibre optic pyrometer
20
Type overview (4) – Two colour fibre optic pyrometer
21
Pyrometer CellaTemp PA 83 with rectangular measuring area
22
CellaTemp PA with fibre optic cable
23
Compatible with entire range of CellaTemp PZ accessories Mounting bracket PA 11/U Pivoting / tilting pedestal mount PA 11/K Protective supplementary quartz lens PA 20/I Protective supplementary ZnS lens PA 10/I Protective supplementary sapphire lens PA 15/I Cooling jacket PA 20/B, PA 20/M Polarizing filter for eyepiece PA 20/P Connection cable VK 02/A USB cable VK 11/D CellaTemp PA – Accessories
24
Pyrometer Connecting cable VK 02/A manual German, Englisch, French depending on order) USB cable VK 11/D Software CellaMevis PZ 10/N AF 10_d_e Type with video camera: video cable VK 02/F incl. adapter to cinch CellaTemp PA – delivery includes
25
CellaTemp PA – cooling housing PA 20/… open: PA 20/B AF 1 closed: PA 20/M AF 1 For pyrometers with throught-the-lens optic or laser spot marker closed: PA 20/M AF 2 für pyrometer with video camera
26
CellaTemp PA – protective housing PA 40/… open: PA 40/B AF 1 closed: PA 40/M AF 1 For pyrometers with throught-the-lens optic or laser spot marker closed: PA 40/M AF 2 für pyrometer with video camera
27
Mounting set PA 20-011 for cooling and protective housing
28
Mounting set PA 20-013 for cooling and protective housing