Dr. Tono Nasch Russia Lubricants 2007, Moscow Online Wear Measurements by means of Radiotracer Technique
2
Overview Conventional Wear Measurements RNT Measurement Principle Activation of Engine Parts RNT Measurement System Examples of RNT Tests Summary
3
Conventional Wear Measurements Engine Components (Examples) Camshaft Cylinder Liner Piston Ring (radial / axial) Piston Ring Groove Bearings Timing Chain […] Precision: 1 µm Based on pre- and post test measurements Long Running Time of Test Engine
4
RNT Measurement Principle The characteristic -radiation of the wear particles originating from the activated area of the engine part is registered by a detector system RNT=Radio – Nuclid - Technique TLA=Thin – Layer - Activation
5
Activation of Engine Components
7
RNT – Area of Application MaterialIsotopeT1/2 [d]Min. Time of Usage [d] Cam / TappetFe / FeCo57 / Co56273 / 78820 / 240 Cylinder Wall / Piston Ring Fe / CrCo56 / Cr5178 / 28240 / 90 Conrod pin / Bearings CuZn65240720 BearingsAlSnNa22 / Sb120m 949 / 5.83000 / 20 BearingsPbSnBi2066.220
8
Example – Activation of Cam & Tappet - 4 mm+ 4 mm Isotope: Co-57 e.g. 30 µm depth 1 – 5 MBq one or several cams activated Isotope: Co-56 e.g. 50 µm depth 10 MBq one or several tappets activated
9
RNT Measurement System
10
CMD – Concentration Measurement Device
11
FMD – Filter Measurement Device
12
RMD – Reference Measurement Device
13
Examples of RNT Tests Volkswagen 650h Test:504.00 / 507.00, 521.95 250h Test:505.01, 521.67 Opel GM-LL-A-025; GEOS A/B BMW BMW Longlife-01/-04
14
Opel RNT Test Test Engine Gasoline Fuel Injection 4 cylinder 16 valve - 1998 cm³ Power max : 100 kW Torque max : 185 Nm Test Criteria Online Wear Rate: Camshaft:max. 5 nm/h (cams 2, 5, 7 inlet activated, Co-57) Tappets:max. 2 nm/h (all 16 tappets activated, Co-56) Test Operation -Running in 15 h -Pre Test Reference 35 h -Variation of speed 56 h (1000 - 6400 min -1 ) -Saw tooth 5 h (1000 min -1 - 6000 min -1 ) -Pitting 5 h (idle - 5000 rpm / WOT) -Variation of oil temperature 12 h (130 - 140 °C) -Post Test Reference10 h ____________________________ -Total138 h
15
VW RNT Test – Test Cycles Total test length 250 h Test 650 h Test
16
VW RNT Test – Online wear results [nm] hrs Oil Temperature Variation Tappet Wear Limit VW 250h Test Limit VW 650h Test Candidate Trends
17
Wear in relation to operational parameters Wear [mg] Oil Temp. [°C]Speed Wear Rate
18
Summary RNT allows non-contact, continuous (online) wear measurements RNT is applicable for all technical ferrous materials RNT allows a selective measurement of critical zones Up to two engine parts can be tested simultaneously regarding their wear behaviour By means of RNT the wear behaviour of engine components in relation to critical running conditions can be evaluated RNT allows wear measurements with a high measuring sensitivity (precision 1nm)
19
Institute for Fuels & Lubes Testing Thank you for your attention