Download presentation
Presentation is loading. Please wait.
Published byAshlyn Emmeline Pope Modified over 9 years ago
1
Bayesian modelling of a diagnostic helium beam ADAS workshop, Armagh Observatory, October 4th, 2010 Maciej Krychowiak M. Brix, D. Dodt, R. König, O. Schmitz, J. Svensson, R. Wolf
2
2 Helium beam diagnostic Radial profiles of n e and T e at the plasma edge n e : 10 12... 10 13 m -3 T e : 10... 200 eV r 1 mm, t 1 ms plasma line of sight helium beam nozzle Measure three spectral lines of atomic helium (typically 667, 706, 728 nm) Compare two line ratios with CR model T e : triplet/singlet n e : singlet/singlet singlettriplet
3
3 direction of the gas flow beam relaxation (steady-state solution) no beam relaxation (time dependent solution) nozzle =0 (stationary beam) electron (de)excitationradiationtransport ionisation charge exchange Beam atoms penetrate the plasma, radiate, get ionised, leave the observation volume Movement in one direction → 1-dim transport equation: CR modelling of helium beams ~ 200 uncertain rate coefficients for electron collisions, known only from calculations Collisions with protons, neutrals
4
4 Comparisons to other diagnostics Comparisons to TS and lithium beam (Schmitz et al. 2008): n e 10%, T e 30% Observed beam penetration smaller than model by 30% Comparative measurements on TEXTOR (Schmitz, et al., Plasma Phys. Control. Fusion 50 (2008) 115004)
5
5 CR model of the helium beam is a complex system with many uncertain parameters Quantitative errors in n e /T e Probabilistic approach provides: Diagnostic design study: application of helium beam in the high density divertor plasma of the stellarator W7-X Statements on atomic data (correction factors, uncertainties) by analysis of (uncertain) experimental data. Why probabilistic CR model for helium beam
6
prior knowledge likelihood Bayesian CR modelling of (relaxed) helium beam posterior marginalised posterior Take n e /T e, simulate line ratios, D 2-dim posterior (parameters of interest) further marginalise 1-dim posteriors 6
7
7 Model assumptions Steady state solution (transport neglected, n e > 2×10 12 cm -3 ) Collisional processes included: electronic (de)excitation and ionization, no charge exchange n = 1-5 included (29 levels) n = 1-4: „helike_hps02he_t3.adf”, n = 5: compilation by Brix (phd) High density, low temperature W7-X divertor plasma: n e = 10 14 cm -3, T e = 5 eV
8
9%9% 4.7% 3.2% 15% 21% 31% 25% n=3-4 30% 45% 8 ADAS dataset „helike_hps02he_t3.adf”: uncertainties 5%5% 20% n=3-4 50%
9
Measure 2 line ratios Relatively large n e /T e errors Diagnostic design study 9 n e =128% T e =45%
10
Measure 3 absolute line intensities beam density (attenuation) uncertain: +/- 50% Strongly reduced n e /T e errors 10 n e =66% Te=8%Te=8%
11
Fit 3 line intensities Measurement error: 5% n e = 66% T e = 8% Enlarge signal noise Increase number of spectral lines Measurement errors 5 → 10% T e : 8.7% 11 Fit one additional line (501.6 nm) T e : 8.5% Fit two more lines (492.2, 504.8 nm) T e : 7.8% n e [cm -3 ] n e = 122% n e = 103% n e = 107%
12
12 n e =50% T e =26% Use comparisons to other diagnostics at TEXTOR: n e = 10%, T e = 30% T e = 32 eV, n e = 4×10 12 cm -3 Run Bayesian analysis using RCs and their uncertainties from „helike_hps02he_t3.adf” Refining the beam excitation model Some RC uncertainties in „helike_hps02he_t3.adf” are overestimated !
13
13 Refining the beam excitation model Priors: RCs from „helike_hps02he_t3.adf” as before New: n e, T e : Gauss profile, width of 10% and 30% respectively (observation) Marginalise over n e, T e and all rate coefficients except for the ones of interest prior knowledge likelihood posterior marginalised posterior Result: RC (1 1 S-3 1 S) 9.9% (11% in ADAS) RC (3 1 S-3 1 P) 18.2% (30% in ADAS) But: The model is not complete Principle suitability of Bayesian analysis for judging atomic data
14
Thank you for your attention
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.