Download presentation
Presentation is loading. Please wait.
Published byDale Bruce Modified over 9 years ago
1
measurement of the absolute BR(K + - + ) : an update Patrizia de Simone KLOE Kaon meeting – 21 May 2009
2
signal selection (I) K tag ,,,, K sig path triggering or 0 tag on one side the virtual path of the signal K is given by the tag K track backward extrapolated to the I.P. before the inner wall of the DC in the signal hemisphere we require two reconstructed tracks making a vertex along the K path before the inner wall of the DC missing mass spectrum we look for the signal in the missing mass spectrum
3
signal selection (II) recovery procedure small changes in the recovery procedure of the K e2 selection selection efficiency require two reconstructed tracks in the DC the selection efficiency should be given by dvt < 3. cm distance between the extrapolated tracks and the K path dvt < 3. cm momentum of the extrapolated tracks in the K rest frame p* < 190. MeV Fiducial Volume0. < vtx < 25 cm Fiducial Volume : 0. < vtx < 25 cm | z vtx | < 20 cm | z vtx | < 20 cm selection efficiency selection efficiency measured on MC corrected with single trk (data) single trk (MC) whole 2002 Data Sample no no charge requirements for the selected tracks p (selected tracks) < 200. MeV/c sel = single trk x single trk x cuts geo ≈ 26 %
4
dataMC missing mass 2 (Mev 2 ) the selected sample tag triggering mass window 10000. < missing mass 2 (MeV 2 ) dataMC missing mass 2 (Mev 2 ) tag triggering
5
the signal to evaluate the background contribution we fit the Missing Mass spectrum using the MC signal and background shapes K + tag triggering ¼ of the 2002 data sample : ¼ of the 2002 data sample : signal conting statistical error ≈ 0.4 % Mass miss 2 bin = 2000 MeV 2 kumacs and help of Erika signal counting window 10000. < M miss 2 MeV 2 varying the fit range -40000. < M miss 2 < 40000. MeV 2 M miss 2 > 0.0 MeV 2 the signal counting is stable within 0.2%
6
K ± ± 0 0 control sample stepping along the K ± sig path build a 2 –like 2 –like variable based on 4 neutral clusters on time on time with the K ± sig ToF 2 < 30 select the 2 best pairing and keep the event if (InvMass( ) 1 – M 0 )/ M < 4..and. (InvMass( ) 2 –M 0 )/ M < 4. M ≈ 18 MeV ) p ± = pK ± – p 0 – p 0 and finally … to measure the single track reconstruction efficiency
7
M miss 2 (MeV) p (MeV) M miss 2 < 400 MeV 2 K ± ± 0 0 control sample: p ± kine resolution p (MeV) M miss 2 < 400 MeV 2 p ≈ 14 MeV X 0 0 vertices found in the FV (0. < vtx < 25. ) cm (0. < vtx < 25. ) cm |z vtx | < 20. cm |z vtx | < 20. cm 62% in 62% of the cases purity 99% the purity of the sample is 99%
8
resolutions: neutral VTX vs DC reconstructed quantities bin p = 30 MeV p (MeV) p ≈ 14 MeV dataMC vtx (cm) vtx ≈ 2.2 cm dataMC ≈ 10 dataMC bin vtx = 5 cm bin = 30
9
distributions of the DC reconstructed quantities dataMC bin 1 bin 2 bin 3 (cm) dataMC bin vtx 1 bin vtx 2 definition of the correction efficiency tables bin = 30 dataMC p (MeV)
10
bin 2 bin vtx 2 bin vtx 1 bin 1 bin 3 bin vtx 2 bin 2 bin 1 p (MeV) correction efficiency tables p (MeV) data(K ± ) sel single trk MC(K ± ) sel single trk K + : tag triggering K + : tag triggering
11
signal selection efficiency signal signal ≡ extrapolated tracks.ge.2 dvt 1 dvt 2 (dvt 1 < 3.).and. (dvt 2 < 3.) cm p* 1 p* 2 (p* 1 < 190.).and.(p* 2 < 190.) MeV mass window p (MeV) selection kine = signal N(K -> 3 ) in FV ifsignal N(K -> 3 ) in FV sel K + red K - blue sel vtx (cm) kine MC folded with single trk (DATA) single trk (MC) K + : tag triggering 0.458 ± 0.001 K + : tag triggering 0.445 ± 0.001
12
tag bias correction estimated from the 2002 MC kpm04 tag triggering tag triggering tag tag K+K+ K-K- (84.115 ± 0.074)% (85.284 ± 0.074)% (84.282 ± 0.114)% (85.404 ± 0.115)% (83.710 ± 0.117)% (85.089 ± 0.117)% (81.290 ± 0.165)% (82.642 ± 0.166)%
13
filfo correction tag triggering tag triggering K+K+ K-K- 1.00403 ± 0.00133 1.00504 ± 0.00124 1.00027 ± 0.00004 1.00050 ± 0.00006
14
T3 filter correction tag triggering tag triggering K+K+ K-K- using the whole DATA sample 1.00072 ± 0.00001.99951 ± 0.00013 1.00042 ± 0.00002 1.00028 ± 0.00001
15
why ? PDG fit ‘06 PDG fit ‘06 BR(K ) = (5,59 ± 0.03)% BR/BR = 5,4x10 -3 CHIANG ’72 CHIANG ’72 (2330 evts) BR(K ) = (5,56 ± 0.20)% BR/BR = 3,6x10 -2 no radiative correction this BR enters in the CUSP analysis to extract the phase shifts done by NA48 the complete set of new measurements of the absolute BRs of the dominant K ± decays to have the complete set of new measurements of the absolute BRs of the dominant K ± decays the 6 absolute BRs all together moreover we will measure the 6 absolute BRs all together with the whole KLOE data set, this will allow us to obtain “easily” the correlations between the K ± BRs measurements (FlaviaNet fit constrained by BR = 1)