Download presentation
Presentation is loading. Please wait.
Published bySandra Dorsey Modified over 9 years ago
1
Robert Johnson Faculty: Dr. Calvin Howell Grad Student: David Ticehurst Development of a Neutron Detector with Kinetic Energy Measurement Capability
2
Motivation Basic research in nuclear physics Scattering Reaction Transfer Reaction Charge Exchange Applications Neutron Detection without using T.O.F method Nuclear Security
3
Proven Technology Moderation and then Charge Exchange Effective as neutron counter Detection Efficiency: 40-45% Timing on the order of μs Scintillation Effective neutron counter Detection efficiency: 20-25% Timing on the order of ns Energy information using T.O.F techniques
4
Experimental Set-up Two PMTs attached to a 10 Boron loaded Analog MPD-4 -> TAC Digital Digitizer Sources used 22 Na (Calibration/Testing) 137 CS (Calibration/Testing) AmBe (Neutron Source)
5
Data Acquisition(PH) Energy Resolution: 26%
6
Data Acquisition(PSD) Pulse Shape Discrimination
7
Data Acquisition(PH vs. PSD)
8
Second Pulse Reaction 10 B + n -> 6 Li + α + ϒ (480 keV) Shows that all the energy in the initial reaction was released in the scintillator Can only be detected with the digital set up
9
Results of Time difference Time (ns)
10
Future Plans Finish the code to analyze the PH, PSD of second pulse Search for the alpha particles
11
References Knoll, Glenn F. Radiation Detection and Measurement. 4th ed. Hoboken: John Wiley & Sons, 2012. Print.
Similar presentations