1 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Electrical Cabinet (EC)

2 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 2 General Description  The electrical cabinet is located inside the electronics cabinet.  The electrical cabinet (structure) is comprised of the base and the panel door.  It receives the main power supply line from the machine – 3X230VAC + Natural + GND – (max.) total of 63A (per phase).  The electrical cabinet is responsible for the following functions:  PDU – power distribution to all components in the machine  Operation of drum heating  Operations of pumps (vacuum and evacuation)  Protections (overheat and under speed)

3 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 3 Structure Base Panel

4 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 4 Inputs Power and auxiliary inputs are located at the bottom of the Electrical cabinet. Input of main power line 3x230VAC+N+GND 63A Max (per phase) Input of UPS Auxiliary outputs

5 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 5 Power Distribution Stabilizer and protection from spikes lightning and noise reducer (up to 20DB) Main contactor 63A CN1 T1-12VAC Transformer for emergency switches

6 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 6 Power Distribution (Cont.) S1-Main circuit breaker (4 pole) S2-Earth leakage current breaker S5-Drum heating breaker S3-UPS breaker

7 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 7 Power Distribution (Cont.) Up to machine 74 CN5 - Vacuum blower contactor CN6 - HA fan contactor CN7 - Evacuation blower contactor OL1 - Vacuum blower overload relay (up to 6.3A) OL2 - Hot air fans overload relay (up to 1.6A) OL3 - Evacuation blower overload relay (up to 1.6A)

8 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 8 Power Distribution (Cont.) From machine 75 CN5 - Vacuum blower contactor CN6 - HA fan contactor OL1- Vacuum blower overload relay (up to 6.3A) OL2 - Hot air fans overload relay (up to 1.6A)

9 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 9 Power Distribution (Cont.) PH1 – Phase relay. Green and orange light indicate the right phase order. If the phase order is wrong, the pumps will not work. Up to machine 74

10 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 10 Power Distribution (Cont.) S6-Breaker of Supply unit, computer and peripherals. S7-Transformer Breaker. S8-Breaker of Auxiliary 1 (J15). S9-Breaker of Auxiliary 2 (J14). S11-Output power to J11 S12-output power to J12

11 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 11 Electrical Cabinet Panel The panel includes:  Drum heat controller board  Receives the requested temperature from the computer and heats the drum with a combination of IR and hot air fans.  Receives feedback of the real drum temperature measured by the IR sensors.  Controls for two under speed protection (Tahco generator and under speed sensor).

12 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 12 Electrical Cabinet Panel (Cont.)  Controls for two separate overheat protections  Temperature readings from two IR sensors under the drum are compared to the preset value in two separate voltage relays.  If the potentiometer on the voltage relay is set to 1, the overheat message appears when the relevant IR sensor reads more then 100ºC.  Dryer enable  HA fans and IR controls, control operations of all pumps.

13 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 13 Door Panel (Cont.)

14 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 14 Door Panel  Voltage relay I – sets the potentiometer to 1 (max) displays the overheat 1 message at 100ºC.  Voltage relay II – sets the potentiometer to 1 (max) displays the overheat 1 message at 100ºC.  Normally, both units are set to 0.8, which means that the overheat is set to 80ºC.

15 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 15 Controller Board (Drum Heat Controller)

16 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 16 Controller Board (Drum Heat Controller) – Cont. CN3-IR heaters contactor CN2-UPS contactor

17 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 17 Controller Board (Drum Heat Controller) – Cont. F7, F8-IR heaters fuses (50A)

18 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 18 Controller Board (Drum Heat Controller) – Cont. U3-24VDC Supply unit for the heating controller

19 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 19 Controller Board (Drum Heat Controller) – Cont. Fuses for lamps and controls S13-Breaker of IR units S15-Heat control breaker

20 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 20 Controller Board (Drum Heat Controller) – Cont. 1 – Solid state relay (SSR) unit for IR I heater control 2 – Solid state relay (SSR) unit for IR II heater control

21 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 21 Indication Lights  L1, L2, L3 – indicates power phases input.  UPS – Indicates UPS power input (external source for computers only).  ON – Lights up after machine initiates (like in the traffic light indicator).  VAC – Indicates when the vacuum pump is working.

22 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 22 Indication Lights (Cont.)  HA – Indicates when the HA fans are working.  EV - Indicates when the evacuation pump is working.  EM SWITCH – Lights up as long as the emergency switches are not pressed.  MAIN/UPS switch selector – Manually switches between UPS and Main Power.

23 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 23 Indication Lights (Cont.)

24 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 24 Panel Door Indication Lights  OV1 – first protection for Over heat (Reading temp’ from first IR sensor)  OV2 – second protection for Over heat (Reading temp’ from second IR sensor)  Tacho speed – first protection for drum under speed from the Tahco generator on the drum motor

25 Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Confidential 25 Panel Door Indication Lights (Cont.)  PROX speed – second protection for drum under speed, monitoring the drum movement by the under speed sensor  24VDC, 24VAC – indicates lights of controls  Enable – dryer enabled signal