Manufacturers of Quality Hydrological, Meteorological & Environmental Instruments & Equipment
2
Established in 1965 Development of Products for these applications: Water Level Water Flow Sediment Sampling Meteorology Data Acquisition Calibration services
3
1. Absolute Shaft Encoders (optional integrated data logger) 2. Constant Bubbler Systems - Nitrogen & 12V *fitted with appropriate non- submersible pressure transducers 3. Pressure Transmitters 4. Non-contact using Radar for measurement of level, surface velocity, or discharge
4
ABSOLUTE AD100A - AD150A - AD375A ABSOLUTE WITH DATA LOGGER AD100AL - AD150AL - AD375AL ABSOLUTE WITH DATA LOGGER AD100AL - AD150AL - AD375AL
5
AD375 Model4-20mASDI-12 Extra SDI-12 Logging with RS232 Rainfall USB Memory Stick StandardAD375MA xxxx Option 1AD375MA/S xxx Option 2AD375MA/L x x Option 3AD375MA/U x
6
WL3100 Model 4-20mASDI-12 Extra SDI-12 Logging w/RS232 Rainfall USB Memory Stick StandardWL3100 xxxx Option 1WL3100/S xxx Option 2WL3100/L x x Option 3WL3100/U x
7
HS-23 Nitrogen Bubbler Precalibrated Regulator Valve Double or Single Line Systems No Site Glass Easily Serviced & Maintained Requires Nitrogen Bottles HS-40 Advanced Bubbler System Inbuilt Air Compressor, 12VDC Low Power Consumption User adjustable bubble rate Inbuilt WL3100 Pressure Transducer Accuracy 0.02% F.S. Maintenance free for up to 5 years
8
Hydrostatic level sensor - ‘Ultra’ low power consumption (30mA continuous) - Maximum water head 30m (100 ft) - In-built air compressor and dryer system - Low Power Consumption - Used in conjunction with the Gas Chamber Orifice Model GCO1 - Maintenance free for up to 8 years - Up to 200 Meters river line 3. ‘Trident’ Hydrostatic System Gas Chamber Orifice Model GCO1
9
Model HS-55DO 2 orifices at two different levels Uses one orifice at a time Only 1 pressure transducer reqd. Model HS-55DB Measures 2 bodies of water simultaneously The orifices can be at two different levels and two different locations. Two pressure transducers required
10
Model HS-55
11
PT2X: PRESSURE/TEMPERATURE SMART SENSOR WITH DATA LOGGING RS485/RS232 interface Small diameter Twist open case Pressure, temperature & time 130,000+ records / non-volatile 316 stainless steel, Viton® and Teflon® construction (Titanium optional) Polyethylene, polyurethane and FEP Teflon® cable options Cableless version available MODBUS® protocol for RTU & PLC applications Easy export to spreadsheets & databases
15
Current Meters Horizontal & Vertical Axis Current Meter Counters & Flow Computers CMCsp Current Meter Counter PVD100 Point Velocity Display ‘HydroMate’ Flow Computer / Discharge Logger Stream Gauging Equipment Portable & Bank Operated Winches ‘Hornet’ Remote Control Cableway Gauging System ‘Top Set’ & ‘Bottom Set’ Wading Rods Sediment, Bedload & Bed Material Samplers
16
Robust Construction Interchangeable Buckets in case of damage High accuracy ±1% Advanced contact switching system Minimum starting velocity 0.025m/s Maximum Velocity 5.0m/s Durable pivot & bearing assembly for long lasting replicated motion Direct velocity reading when used with the CMCsp, PVD100 or HydroMate Model RB1 - New Vertical Axis Current Meter
17
Model OSSB1 Universal Current MeterModel OSSB1 Universal Current Meter Fan TypeSize Max Velocity m/s Start Velocity m/s Range of Component Effects A100mm x 0.125m5.00.025 ± 45 ° 1125mm x 0.25m10.00.025 ± 5 ° 2125mm x 0.50m10.00.040 ± 5 ° 480mm x 0.125m4.00.040 ± 5 ° Stainless Steel construction - resists corrosion and damage Rubber encapsulation of the Reed Switch to resist damage from dropping or knocking Hockey Stick’ style Sewer Rod to position meter in pipe for man hole Minimum Starting Velocity 0.025m/sec Stainless Steel Propellers, 4 Sizes Non Contact Switching
18
Model OSSPC1 Pygmy Current Meter TypeSize Max Velocity m/s Start Velocity m/s Range of Component Effects A100mm x 0.125m5.00.025 ± 45 ° 1125mm x 0.25m10.00.025 ± 5 ° 2125mm x 0.50m10.00.040 ± 5 ° 480mm x 0.125m4.00.040 ± 5 ° For Measuring Water Velocities from 0.025 to 6.0 m/sec Streamlined and Robust Nickel Silver Body Stainless Steel Axle Anodized Aluminum Propellers,3 sizes Non Contact Switching System - Permanent Magnet and Reed Switch Special Sewer Model Available
19
Model CMCsp Current Meter Counter & Signal Processor Direct Velocity Reading Digitally processes and ‘cleans’ signals from Catwhisker and Magnetic Head Meters Operates with two ‘AA’ batteries Works in high conductivity water( > 50,000μSiemens) Self contained unit with 2 x 8 character LCD display showing total meter counts and elapsed time Integrated Bluetooth Interface and RS232 Interface Also operates with any Palm, PocketPC, or Field Computer. Fully self calibrating ‘Self Test’ for Serial Interface setup Can display and produce ‘Spin Test’ record Selectable 10 second to 90 second fixed measuring intervals; default is 40 seconds Total Counts to 999, Total Time to 999.9 seconds Range of Measurement from 50 ft/sec Continuous measuring mode (no time limit) Automatically indicates fault conditions
20
Model PVD100 Point Velocity Display Direct Velocity Reading Digitally processes and ‘cleans’ signals from Catwhisker and Magnetic Head Meters Operates with two ‘AA’ batteries Works in high conductivity water( > 50,000μSiemens) Self contained unit with 2 x 8 character LCD display showing total meter counts and elapsed time Integrated Bluetooth Interface and RS232 Interface Also operates with any Palm, PocketPC, or Field Computer. Fully self calibrating ‘Self Test’ for Serial Interface setup Can display and produce ‘Spin Test’ record Selectable 10 second to 90 second fixed measuring intervals; default is 40 seconds Total Counts to 999, Total Time to 999.9 seconds Range of Measurement from 50 ft/sec Continuous measuring mode (no time limit) Automatically indicates fault conditions
21
All functions are touch screen selectable, which include setting parameters, data input and download. State of the art microprocessor based instrument used to measure the discharge of water when used in conjunction with Current Meter Fans and operates as an autonomous unit. Allows up to 32 fan calibration formulas to be entered for accurate direct reading of river flow. Capable of storing 30 sites of data with 30 verticals per site and 11 points per vertical Re-chargeable batteries (2 ‘D’ cell) and inbuilt battery charging circuit, high temperature LCD touch screen control. Rabbit 2000 Microprocessor 4 Mbit Flash Memory On Board 8 Mbit Serial EEPROM Data Memory 4 Mbit RAM Data Buffer Communications RS232 port configured as DCE.
22
WS400 Single Drum Boat/Bridge Gauging Winch For cable suspended current meter measurements sediment, bed- material & bed-load sampling. Replaces both USGS A reel B Reel. DDT600 Bank Operated Double Drum Gauging Winch for stream flow measurements, sediment, bed-material & bed-load sampling, suspending current meters where bridges or boats are not suitable. Used with Travellerways with span up to 200ft. HORNET Remote Controlled River Gauging System Used on spans up 1km (.62 miles) Portable 12VDC powered Hoist can be used on multiple cableways No maintenance required Used with mechanical current meters as well as ADCP’s (Acoustic Doppler Current Profilers) Radio Controlled Hoist with 1KM range. Automatic Wet Line / Dry Line Correction Automatic Correction for Cable Sag (distance traveled).
23
Used on spans up 1km (.62 miles) Portable 12VDC powered Hoist can be used on multiple cableways No maintenance required Used with mechanical current meters as well as ADCP’s (Acoustic Doppler Current Profilers) Radio Controlled Hoist with 1KM range. Automatic Wet Line / Dry Line Correction Automatic Correction for Cable Sag (distance traveled). Suitable for ADCP OR conventional current meter Auto-correction of distance and depth (air / wetline) Variable traversing speed (maximum 1m/sec or 3.28ft /sec) Wireless hand- control Depth Measurement Resolution (0.01m OR 0.01ft) Built-in Signal Processor for Mechanical Current Meters
27
ML1-420 is replacing all ML data loggers 1 digital input for rainfall or flow meters etc. 1 analog input 4-20 mA for water level 1 input for ambient temperature external battery voltage monitoring, internal battery volt monitoring, Event storage of 600,000 events RS232 Port for connection to modem, data download & programming. Internal power supply: Internal lithium, alkaline, or rechargeable battery. External Power Supply: 12 V DC.
28
New, very low power processor. Touchpad now 4-button keypad. LCD true graphics (128x64 pixels). Logging memory 8MB. SDI-12 support. User replaceable lithium battery. Diecast aluminium enclosure. Two NG12 glands for cable entry. Internal jumper links for current inputs and debounce selection. iRIS 150
29
Lighter, diecast aluminums enclosure. LCD true graphics (128x64 pixels). Logging memory now 8MB. RS232 connector now external. 4 x Digital I/O ports. Can be in or out. Four NG16 glands for cable entry. iRIS-CAM adaptor built-in. User replaceable backup battery. Fixed 5V excitation output now supports variable voltage or current. Internal links for current input and debounce selection. Has been released with same software as iRIS 220/320. iRIS 350
31
Hydrological Services ongoing R&D program will continue to provide water cycle measurement and monitoring solutions for a wide range of International clients Questions?