Variable Frequency Drives (VFDs) for Potato/Onion Shed Fans UES Measure Update Regional Technical Forum April 23, 2014.

Similar presentations


Presentation on theme: "Variable Frequency Drives (VFDs) for Potato/Onion Shed Fans UES Measure Update Regional Technical Forum April 23, 2014."— Presentation transcript:

1 Variable Frequency Drives (VFDs) for Potato/Onion Shed Fans UES Measure Update Regional Technical Forum April 23, 2014

2 Today’s Agenda Measure Overview Staff Highlighted Areas Estimate of Measure Potential Review Measure Workbook – Summary of Updates – Savings, Cost, and TRC RTF Staff Recommendation Proposed Decision 2

3 3 Photo courtesy of Ryan Firestone

4 4 Potato/Onion Shed VFDPotato/Onion Shed VFD Measure Overview Current Category: Proven Current Status: Out-of-Compliance Current Sunset Date: April 30, 2014 Reason for Update/Review: Bring measure into compliance

5 Staff Highlighted Areas Staff recommends bringing measure into compliance as Small Saver – Estimated remaining potential on the order of 0.5 to 1 aMW – Staff agrees that current savings analysis reasonable for Small Saver UES 5

6 Estimate of Measure Potential Bonneville provided potato/onion shed VFD achievements for its utilities from ‘09 - ’13 Reported projects have fallen significantly since 2009 – 2009: 31 projects – 2010: 5 projects – 2011: 1 project – 2012: 3 projects – 2013: 0 projects (as of August) Total savings reported since 2009: 0.67 aMW 6

7 Estimate of Measure Potential According to BPA, well over half of the potential in its territory has already been converted to VFDs Staff also reached out to Idaho Power – No estimate of remaining potential; however, – 90+% of its potato/onion shed VFD projects have been in NEW sheds, not retrofits – Only two retrofit projects in the last two years Staff estimates remaining potential for this measure on the order of 0.5 to 1 aMW 7

8 Summary of Updates Updates based on recommendation memo – Ported analysis into latest ProCost template – Cleaned up workbook documentation and analysis – Updated measure savings to reflect results of measured BPA project data instead of conservative rounding of results 8

9 Measure Workbook Go to the following sections in the Summary tab in the proposed measure workbook:proposed measure workbook – Measure Properties and Identifiers – Constant Parameters – Energy Savings Estimation Method, Parameters and Data Sources – Measure Incremental Costs and Benefits – Measure Lifetime 9

10 Savings, Cost, and TRC Energy savings increased by 19% – Previous analysis used conservative assumption of 1,000 kWh savings per HP – Proposed analysis uses actual savings resulting from analysis (1,193 kWh/HP) Slight decrease in incremental costs (~1%) Cost-effectiveness remains unchanged – All measures cost effective except 5HP size 10

11 RTF Staff Recommendation Approve the Variable Frequency Drives - Potato/Onion Shed measure as a Small Saver UES Set the sunset date to five years from now 11

12 Proposed Decision “I _______________ move that the RTF: Approve the Variable Frequency Drives - Potato/Onion Shed measure as a Small Saver UES; Set the measure status to Active; and Set the sunset date to April 30, 2019.” 12