Additional Data Evaluation of the Daphnia Toximeter and its Benefits Arco Wagenvoort & Corina Carpentier AquaLife Workshop, Kiel, Germany 31 st May 2010
2
Introduction History of alarm detectors Evaluation in addition to Hinkley and Gradient detectors insight into types of changes Examples of advanced data evaluation and assessment of alarm situations
3
History: The Daphnia Test Alarm: activity below lower alarm threshold Upper alarm threshold unusable: drift, insensitive
4
Drift: growth leads to an increase of average swim speed
5
Improvements Daphnia Test ALARM: activity below lower alarm threshold Upper alarm threshold unusable: drift, insensitive 1994 - introduction of Hinkley detector ALARM: response to sudden changes 1999 - introduction of two gradient detectors relatively slow rise or fall in parameter values
6
Hinkley detector and gradient detectors
7
Data evaluation based on changes compared to previous data-points De Hoogh-Carpentier et al. (2006) and Wagenvoort et al. (2006): standardisation and quality assurance protocols introduction of size-based alarm thresholds and a mortality parameter to explain the “action mode” of chemicals (in use since 2004) ADVANCED DATA EVALUATION
8
Size-based data evaluation Standardisation: use of animals of the same age (24 - 48 h) Growth after (simultaneous) moulting Larger animals show a greater swim speed range
9
Noise of signal increases with size
10
“Normal” values derived for Keizersveer Monitoring Station
11
Normal growth pattern of Daphnia Size of Daphnia Number of Daphnia
12
Growth: indicator for Daphnia well-being Alarm situation at Eijsden Monitoring Station
13
Size-based data-evaluation: summary Comparison to absolute values for swim speed Early detection of technical malfunction (e.g. clogging of feeding tubes) Indication of Daphnia well-being in general Explanation of action mode of chemicals that cause alarms: hyperactivity paralysis
14
Example 2004/2005 : increased swim speed and mortality caused by 3-cyclohexyl-1,1- dimethylurea De Hoogh-Carpentier et al. (2006)
15
Example 2004/2005 : increased swim speed and mortality caused by 3-cyclohexyl-1,1- dimethylurea
16
Example 2007: increased swim speed and mortality caused by chlorpyrifos and diazinon Wagenvoort et al. (2010)
17
Determination of the end of an alarm The decrease in the Toxic Index does NOT mean that the alarm situation is over!
18
Example 2007: spill of chlorpyrifos and cypermethrin in River Meuse by Chimac- Agriphar near Liege Mortality of replaced Daphnia
19
Advanced data evaluation: recent results from the River Meuse
20
Advanced data evaluation for the River Meuse Period: Eijsden: 2007 Beegden: 2009 Keijzersveer: 2007-2009
21
Advanced data evaluation - summary Results of the Daphnia Toximeter are reliable and reproducible Quality assurance protocols reduce number of false positive alarms Use of size-based alarm limits and individual parameter assessments provide: earlier response indication of action mode of chemicals Evaluation method shows more alarms, but almost always the causes can be found
22
Thank you for your attention Acknowledgement: Colleagues at Eijsden, Beegden and Keizersveer Monitoring Stations in NL Arco Wagenvoort & Corina Carpentier AquaLife Workshop, Kiel, Germany 31 st May 2010