Final Review of the 2004 NAIP Digital Orthoimagery of Texas NAIP DOQ November 10, 2005 Gordon Wells and Linda Prosperie UT Center for Space Research.

Similar presentations


Presentation on theme: "Final Review of the 2004 NAIP Digital Orthoimagery of Texas NAIP DOQ November 10, 2005 Gordon Wells and Linda Prosperie UT Center for Space Research."— Presentation transcript:

1 Final Review of the 2004 NAIP Digital Orthoimagery of Texas NAIP DOQ November 10, 2005 Gordon Wells and Linda Prosperie UT Center for Space Research

2 NAIP QA Assessment Procedures Phase 1. Comprehensive review of all MrSID County Mosaics Four Operators inspected: 1 geometry checkpoint per 7.5-minute quad (64 square miles) Noted all radiometric errors and cloud cover Phase 2. Selective review of quarter-quad GeoTIFFs Four Operators inspected: All geometric errors >7 m detected during Phase 1 A random selection of additional quarter-quad GeoTIFFs Noted all radiometric errors and cloud cover

3 Points QQs Percent of 17725 QQs County Mosaics 6026 5351 30.2 GeoTIFF Quarter-Quads 989 989 5.6 Total 7015 6340 35.8 NAIP QA/QC All Checkpoints

4 GeoTIFF Quarter-Quad points 989 GeoTIFF Quarter_Quads 989 NAIP QA/QC GeoTIFF Checkpoints

5

6

7

8 NAIP QA/QC All GeoTIFFs 3.1633 2.5384 Mean Displacement Median Displacement Mosaics 2.6423 2.4270 Mosaics + All GeoTIFFs 3.1219 2.4483 Random GeoTIFFs 2.6604 2.6653 Mean and Median Displacement

9 Mosaics 2.074 2.261 3.068 4.656 1.942 2.458 3.133 4.754Random GeoTIFFs XRMS YRMS Radial Circular RMSE Error All GeoTIFFs 2.709 3.068 4.093 6.211 Mosaics + All GeoTIFFs 2.175 2.392 3.233 4.906 NAIP QA/QC Accuracy Statistics

10 1:4800 1” = 400’ 1:6000 1” = 500’ 1:12000 1” = 1000’ 1:2400 1” = 200’ 4.05 m 5.09 m 10.15 m 2.04 m 4.60 m 5.79 m 11.58 m 2.32 m 2.44 m 3.35 m 6.71 m 1.34 m Map Scale NMAS Circular Error NSSDA Radial Accuracy NSSDA Radial RMSE National Accuracy Standards

11 1:4800 1” = 400’ 1:6000 1” = 500’ 1:12000 1” = 1000’ 1:2400 1” = 200’ 4.05 m 5.09 m 10.15 m 2.04 m 4.60 m 5.79 m 11.58 m 2.32 m 2.44 m 3.35 m 6.71 m 1.34 m Map Scale NMAS Circular Error NSSDA Radial Accuracy NSSDA Radial RMSE Texas NAIP 4.91 m5.62 m3.23 m Texas NAIP & Accuracy Standards

12 NAIP QA/QC Quarter-Quads with Clouds 731 or 4.12%

13 NAIP QA/QC Quarter-Quads With >10% Clouds 88 or 0.496%

14 NAIP QA/QC Quarter-Quads With Other Defects Mosaics 274 GeoTIFFs 316 Less Overlap 97 Total 483

15 NAIP QA/QC Defects other than Clouds

16 NAIP Anomaly Specular Reflection

17 NAIP Anomaly Boeing 737

18 Summary Geometric Accuracy is high. 14 of 7015 points checked (0.2%) failed. Extrapolates to <40 quarter-quads in the state. Cloud Cover is a factor. Impacts 731 quarter-quads (4.12%). By specification, causes rejection of 88 quarter quads (0.5%). Radiometric Flaws need to be addressed. Impacts 483 quarter-quads (2.72%). Severe instances would likely cause rejection of approximately 100 quarter-quads (0.6%).