Download presentation
Presentation is loading. Please wait.
Published byTerence Jones Modified over 9 years ago
1
1 4 th International Symposium on Flood Defence: Managing Flood Risk, Reliability and Vulnerability, Toronto, Ontario, Canada, May 6-8, 2008 J. Chen, J. Fooks and H. Goertz Water Survey Division Environment Canada 2008.05 Stage-Discharge Rating with ADCP Measurements
2
2 Introduction Discharge measurement techniques ADCP data analysis Stage-discharge rating Conclusions Presentation Outline
3
3 Water Survey of Canada
4
4 Discharge Measurement with Traditional Techniques
5
5 Limitations of Current Meter Measurement Discrete points and assumed vertical velocity profile Limited range of velocity (>6 cm/s) Time consuming Safety concerns
6
6 Discharge Measurement with Acoustic Techniques
7
7 Advantages of Acoustics Techniques Continuous velocity profiling with directional capability Extended range of velocity measurement Shortened field measurement time Ability to correct data files in post- processing Safety concerns decreased
8
8 Discharge Measurement with ADCP From USGS report
9
9 Discharge Measurement with ADCP (Cont’d)
10
10 Velocity Magnitude Contour Discharge Measurement June 11, 2002
11
11 Discharge Measurement with ADCP – 5 Components Top subsection Bottom subsection Channel subsection measurable with an ADCP Right bank subsection Left bank subsection
12
12 Percentage of ADCP Measured Component Q
13
13 Correlation Among Component Discharges (Q-Q) Q total Q left Q top QmQm Q bottom Q right Q total - Q left 0.655- Q top 0.9360.851- QmQm 0.9970.6260.914- Q bottom 0.9810.7530.9810.964- Q right 0.5030.3100.4730.4710.538- Pearson Correlation
14
14 Correlation Analysis of Component Discharge (H-Q)
15
15 Discharge Computation Methods Standard stage-discharge rating Non-standard methods for discharge computation Index-velocity rating Flow-velocity distribution
16
16 Stage vs. Measured Q Rating
17
17 Stage vs. Estimated Top, Bottom Components Q Rating
18
18 Stage vs. Estimated Left, Right Components Q Rating
19
19 Stage – Discharge Rating Results Comparison
20
20 H&Q Rating with Single Transect Measurements Discharge measurement from each transect is considered as an independent measurement Significantly increase the number of measurements for rating curve development
21
21 H&Q Rating with Single Transect Measurements
22
22 ADCP measurements with 5 components allow for exploration of disaggregated rating methods Component discharge rating It appears that H-Q rating quality does not vary significantly, regardless of whether discharge components are summed prior to rating calibration, or if individual component rating results are summed Component discharge percentages can provide future knowledge of error sources at particular sites Conclusions
23
23 Single transect analysis Using an average of 4 transects or individual transects does not significantly affect the H & Q rating accuracy Further study with rapidly changing stage could provide more depth to this analysis Conclusions (Cont’d)
24
24 Comments on Stage Discharge Rating
25
25 Comments on Stage Discharge Rating (Cont’d)