Download presentation
1
Mpcs la lte ho parameters trial
2
Overview A study on the effect of handover parameters on the network performance will be done in a trial cluster (part of Cerritos) The parameter change to be implemented as an iterative process with each drive and the results to be compared to analyze the effect of the parameters Following parameters to be changed A3offset; hysteresisA3; filtercoefficientEutranRsrp; sMeasure; timetotriggerA3
3
Review: LTE HO Evaluates if one or more intra frequency cell is better than current serving cell UE receives measurement configuration in RRC Connection Reconfiguration No measurement list sent to UE (UE search for all 504 physical cell id and reports the cell(s) fulfilling the event criteria). UE Event Trigger controlled by: – Filtering (How much averaging is done before event evaluation) – Offset (How much better in dB) – Time to trigger (For how long)
4
Main Trigger Parameters
sMeasure = 0 { , 0 } [dBm] Controlling if the UE is required to perform measurements. Disabled if set to “0” (used only RSRP is the trigger) a3offset = 30 { } [0.1 dB] Offset value for EventA3, added to serving cell hysteresisA3 = 10 { } [0.1 dB] Hysteresis value for eventA3, added to neighbor cell timeToTriggerA3 = 40 { 0, 40, 64, 80, 100, 128, 160, 256, 320, 480, 512, 640, 1024, 1280, 2560, 5120 } [ms] Time after Event A3 is fulfilled when UE starts to send Measurement reports triggerQuantityA3 = RSRP [RSRP,RSRQ] The quantity that triggers the event cellIndividualOffsetEUtran Offset value specific to a neighbor relation
5
Handover Filtering To avoid that the measurement reporting is triggered by fast fading, the measurement configuration contains filter coefficient for the UE to use filterCoefficientEUtraRsrp = 9{ 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 13, 15, 17, 19 } Filter coefficient for RSRP measurements filterCoefficientEUtraRsrq = 11{ 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 13, 15, 17, 19 } Filter coefficient for RSRQ measurements
6
Event A3: A neighbour cell(b) becomes offset better than serving cell(a)
7
Drive Info Test Parameter Drive Details Date Started Time Started
Date Finished Time Finished Baseline - 12/17/2010 21:15:00 12/13/2010 00:30:00 Offset1 a3offset=10 12/23/2010 21:00:00 23:15:00 Offset2 a3offset=20 12/27/2010 20:30:00 23:00:00 Offset3 a3offset=30 12/28/2010 01:45:00 Hyst1 hysteresisA3=30 12/29/2010 20:00:00 22:15:00 Hyst2 hysteresisA3=40 12/30/2010 22:30:00 Hyst3 hysteresisA3=60 12/31/2010 01:30:00 Hyst4 hysteresisA3=70 01/03/2011 20:15:00 01/03/2010 TTT1 timeToTriggerA3=80 01/05/2011 22:45:00 TTT2 timeToTriggerA3=160 01/06/2011 00:45:00 TTT3 timeToTriggerA3=320 01/12/2011 FC1 filterCoefficientEUtraRsrp=7 02/13/2011 01:00:00 FC2 filterCoefficientEUtraRsrp=5 01/13/2011 FC3 filterCoefficientEUtraRsrp=13 01/14/2011 FC4 filterCoefficientEUtraRsrp=11 SM1 sMeasure=-70 01/15/2011 19:45:00 SM2 sMeasure=-80 01/17/2011 BL2 Baseline2 01/18/2011 BL3 Baseline3 01/19/2011 Hyst0 hysteresisA3=20 01/20/2011 Hyst5 hysteresisA3=80 01/21/2011 20:45:00 23:30:00 TTT0 timeToTriggerA3=0 01/25/2011 02:45:00 SM3 sMeasure=-90 19:00:00 21:30:00 01/26/2011 TTT4 timeToTrigger=640 01:15:00 03:00:00
8
Trial Cluster – Drive Route
9
Baseline Test Cases MO Parameter Baseline BL2 BL3 UeMeasControl
sMeasure -80 filterCoefficientEUtraRsrp 9 5 4 ReportConfigEUtraBestCell hysteresisA3 50 30 timeToTriggerA3 40 480 a3offset 10 Baseline Baseline 2 Baseline 3 Cell Availability 100% Retainability (Session Failure Rate) 0% 26% Integrity DL Throughput Mean (kbps) Integrity DL Throughput Max (kbps) Mobility (Handover Success Rate) FTP DL session starts 14 19 FTP DL session ends EUTRAN Intra-frequency Handover Failed events EUTRAN Intra-frequency Handover (success) events 192 322 161
10
Baseline Test Cases (contd)
Baseline2 drive demonstrated the highest number of handovers and the smallest delta in RSRP/RSRQ.
11
Baseline Test Cases (contd)
Baseline drive demonstrated the best SINR performance.
12
A3offset Test Cases MO Parameter Baseline Offset1 Offset2 Offset3
UeMeasControl sMeasure filterCoefficientEUtraRsrp 9 ReportConfigEUtraBestCell hysteresisA3 50 timeToTriggerA3 40 a3offset 10 20 30 Baseline (0) a3offset=10 a3offset=20 a3offset=30 a3offset=40 Cell Availability 100% Retainability (Session Failure Rate) 0% Integrity DL Throughput Mean (kbps) 2365 Integrity DL Throughput Max (kbps) 3632 3696 Mobility (Handover Success Rate) 99.23% FTP DL session starts 14 13 18 FTP DL session ends 17 EUTRAN Intra-frequency Handover Failed events 1 EUTRAN Intra-frequency Handover (success) events 192 161 129 118 99
13
A3offset Test Cases (contd)
There was a clear decrease in the number of handovers and an increase in the RSRP/RSRQ delta as went from a3offset=0 to a3offset=40. This is expected as the sum of hysteresisA3 and a3offset increases. Notice, as expected, Delta RSRP ~ hysteresisA3+a3offset.
14
A3offset Test Cases (contd)
Baseline (smallest offset) demonstrated the best SINR performance.
15
HysteresisA3 Test Cases
MO Parameter Hyst0 Hyst1 Hyst2 Baseline Hyst3 Hyst4 Hyst5 UeMeasControl sMeasure filterCoefficientEUtraRsrp 9 ReportConfigEUtraBestCell hysteresisA3 20 30 40 50 60 70 80 timeToTriggerA3 a3offset hysteresisA3=20 hysteresisA3=30 hysteresisA3=40 Baseline (50) hysteresisA3=60 hysteresisA3=70 hysteresisA3=80 Cell Availability 100% Retainability (Session Failure Rate) 19% 0% Integrity DL Throughput Mean (kbps) 2548.9 Integrity DL Throughput Max (kbps) 3590.4 3643.2 Mobility (Handover Success Rate) FTP DL session starts 16 13 14 12 FTP DL session ends EUTRAN Intra-frequency Handover Failed events 1 EUTRAN Intra-frequency Handover (success) events 417 337 224 192 131 140 121
16
HysteresisA3 Test Cases (contd)
There was a clear decrease in the number of handovers and an increase in the RSRP/RSRQ delta as went from hysteresisA3=20 to hysteresisA3=80. This is expected as the sum of hysteresisA3 and a3offset increases. Notice, as expected, Delta RSRP ~ hysteresisA3+a3offset.
17
HysteresisA3 Test Cases (contd)
hysteresisA3=20 (smallest hysteresis) demonstrated the best SINR performance.
18
TimeToTriggerA3 Test Cases
MO Parameter TTT0 Baseline TTT1 TTT2 TTT3 TTT4 UeMeasControl sMeasure filterCoefficientEUtraRsrp 9 ReportConfigEUtraBestCell hysteresisA3 50 timeToTriggerA3 40 80 160 320 640 a3offset timeToTriggerA3= 0 Baseline (40) timeToTriggerA3= 80 timeToTriggerA3= 160 timeToTriggerA3= 320 timeToTriggerA3= 640 Cell Availability 100% Retainability (Session Failure Rate) 0% Integrity DL Throughput Mean (kbps) Integrity DL Throughput Max (kbps) 3696 Mobility (Handover Success Rate) FTP DL session starts 13 14 FTP DL session ends EUTRAN Intra-frequency Handover Failed events EUTRAN Intra-frequency Handover (success) events 187 192 197 186 171 120
19
TimeToTriggerA3 Test Cases (contd)
Number of handovers decreased and RSRP/RSRQ delta increased with the increasing timeToTrigger. This is as expected.
20
TimeToTriggerA3 Test Cases (contd)
timeToTriggerA3=0 and Baseline(40) demonstrated the best SINR performance.
21
FilterCoefficientEutraRSRP Test Cases
MO Parameter FC0 FC2 FC1 Baseline FC4 FC3 UeMeasControl sMeasure filterCoefficientEUtraRsrp 3 5 7 9 11 13 ReportConfigEUtraBestCell hysteresisA3 50 timeToTriggerA3 40 a3offset filterCoefficientEUtraRsrp=3 filterCoefficientEUtraRsrp=5 filterCoefficientEUtraRsrp=7 Baseline (9) filterCoefficientEUtraRsrp=11 filterCoefficientEUtraRsrp=13 Cell Availability 100% Retainability (Session Failure Rate) 0% Integrity DL Throughput Mean (kbps) 2661.5 Integrity DL Throughput Max (kbps) 3590.4 Mobility (Handover Success Rate) 99.38% 100.00% FTP DL session starts 13 14 FTP DL session ends EUTRAN Intra-frequency Handover Failed events 1 EUTRAN Intra-frequency Handover (success) events 269 262 214 192 161 141
22
FilterCoefficientEutraRSRP Test Cases (contd)
Number of handovers decreased and RSRP/RSRQ delta increased with the increasing filterCoefficientEUtraRsrp. This is as expected as the number of measurement samples analyzed for each handover increases.
23
FilterCoefficientEutraRSRP Test Cases (contd)
Baseline gave the best SINR performance.
24
sMeasure test cases MO Parameter Baseline SM1 SM2 SM3 UeMeasControl
-70 -80 -90 filterCoefficientEUtraRsrp 9 ReportConfigEUtraBestCell hysteresisA3 50 timeToTriggerA3 40 a3offset Baseline (0) sMeasure=-70 sMeasure=-80 sMeasure=-90 Cell Availability 100% Retainability (Session Failure Rate) 0% Integrity DL Throughput Mean (kbps) Integrity DL Throughput Max (kbps) 3643.2 3590.4 Mobility (Handover Success Rate) 99.5% FTP DL session starts 14 13 FTP DL session ends EUTRAN Intra-frequency Handover Failed events 1 EUTRAN Intra-frequency Handover (success) events 192 188 204 193
25
sMeasure test cases (contd)
No apparent trend was observed between these drives.
26
sMeasure test cases (contd)
The effect of sMeasure parameter on the network is inconclusive in regards to the performed drives.
27
Summary Tested parameters for the most part resulted in the expected behavior: Number of Handover events. RSRP/RSRQ delta upon Handover. Pre-handover SINR performance. Part of the unexpected behavior can be attributed to the variation in drive test setup between some of the drives. The effect of sMeasure parameter on the network is inconclusive at this point. It will be further analyzed during the testing on DAS nodes. Current Baseline is pretty suitable to the network at this early stage of operation. It is recommended that optimization, when performed, be performed on a case by case basis.
28
THANK YOU