Presentation is loading. Please wait.

Presentation is loading. Please wait.

Topics WildCAD6 Schedule WildCAD6 as a user/dispatcher

Similar presentations


Presentation on theme: "Topics WildCAD6 Schedule WildCAD6 as a user/dispatcher"— Presentation transcript:

1 Topics WildCAD6 Schedule WildCAD6 as a user/dispatcher
WildCAD6 as the WildCAD System Administrator

2 WildCAD6 Schedule 03/26/2014 Begin installation in Test Centers, run in parallel 03/28/2014 Final test version WildCAD6 04/07/2014 Reports from Test Centers due 04/11/2014 New version of WildCAD6 04/18/2014 Reports from Test Centers due Once any major problems fixed, Test Centers can go live with IRWIN Interface, remaining Centers can begin installation

3 WildCAD6 Move from Microsoft Access to Microsoft SQL Server
Security More robust, designed for multi-user Complete rewrite of WildCAD Direction to maintain look and feel, except: Enhancements to support IRWIN Database specific (e.g. backups)

4 WildCAD5 WildCAD6 Workstation Workstation Shortcut to WildCAD.exe
WildCAD Server WildCAD.mdb WildCAD.exe \GIS folder WildCAD Base Computer WildCADSQL Instance WildCAD6.exe \GIS folder WildCADservice.exe Workstation Shortcut to WildCAD.exe C:\WCADtemp WorkstationSetup Workstation Shortcut to WildCAD6.exe WorkstationSetup

5 WildCAD Integration Server
IRWIN WildCAD Integration Server WildCAD Base Computer Other Systems: FireCode WFDSS Sit/209 EGP Workstation Workstation Workstation

6 WildCAD6 Startup Enter IP Address of WildCAD Base Computer.
Not necessary from then on. Auto-login based on Windows Username

7 Changes for Dispatchers

8 Incident Screen Discovery Acres Responsible Center, ADS

9 Conflicts Shows if IRWIN detects a possible conflict:
From a different Center Discovery Date/Time within 6 hrs Within half mile

10 Conflict Resolution “My Incident is the same” makes this Incident inactive in IRWIN “My Incident is a separate fire” keeps this as a separate incident “I need to check further” keeps the red CONFLICT button

11 Fiscal / Complex Tab Get FireCode button, enabled once Incident sent to IRWIN Complex Management

12 WFDSS/IRWIN Tab Eventually remove WFDSS Export

13 (Temporary?) Utilities

14 Changes for WildCAD Sys Admin

15 Dispatchers (Optional) Enter Windows Username for auto-login

16 Center Information Official Center ID IRWIN Interface

17 Units NWCG UnitID is critical Agency
BlockIRWIN if True means do not send these Incidents to IRWIN (cannot block for federal Units.)

18 Resources Resource Category / Type
(See complete list on Database Browser: ResourceKCT)

19 Auto Backups Performed by WildCADservice On the Base Computer

20 Validate NWCG UnitIDs Critical that Official CenterID is valid
Resources must belong to valid UnitID In order to be reported to IRWIN


Download ppt "Topics WildCAD6 Schedule WildCAD6 as a user/dispatcher"

Similar presentations


Ads by Google