Download presentation
Presentation is loading. Please wait.
Published byEileen Rosalyn Lamb Modified over 9 years ago
1
Fitting BiOptic Telescopes: Determining Location and Mounting Angle with BiOptic Fitting Apertures Robert B. Greer, O.D., F.A.A.O. University of California, Berkeley School of Optometry
2
BiOptic fitting apertures Opaque black rings Varying outside diameters –Outside diameter noted in the corner of the aperture –14, 16, 19, 22, 24, 27 and 33mm Central 3mm clear zone Static cling vinyl Easily positioned on the lens
3
BiOptic fitting apertures - benefits Confirmation of vertical and horizontal placement of BiOptic telescopes Direct measurement of the telescope mounting angle Allows patient and doctor to see where the telescope will be located Shows how much of the lens will be occupied by the telescope Enables the patient/doctor to see what head movement is needed to access the telescope
4
BiOptic fitting apertures Outside diameter, in mm, is noted in the upper left corner of each aperture
5
Vertical placement For distance, the BiOptic telescope is usually mounted centrally or high in the lens Usually as high in the lens as possible, especially for driving or if near tasks will also be performed while wearing a distance BiOptic 3mm between the edge of the telescope and frame must remain for lens structural strength For near, the BiOptic telescope is mounted centrally or low in the lens Central location may work best for computer use
6
Vertical placement Aperture high on the lens for distance use Aperture low on the lens for near use
7
Horizontal placement - distance For distance the telescope is placed at the monocular distance inter-pupillary distance (IPD) The IPD is often measured using traditional techniques such as rulers or corneal reflection pupillometers
8
Horizontal placement - near For near the telescope is placed at the monocular near PD appropriate for that working distance Ian Bailey created a “rule of thumb” for calculating the near IPD: Near IPD = Distance IPD - 1.5(working distance) –The working distance is expressed in diopters Example –A patient with a 65 mm distance IPD wants to work at 25 cm which is a working distance of 4 diopters –Near IPD = 65 - 1.5 (4) = 59 mm
9
Mounting angle The telescope must be angled so that its viewing axis points towards the eye’s center of rotation BiOptic fitting apertures allow for a direct measurement of the mounting angle Mounting angle is referenced to the frame front A telescope mounted perpendicular to the frame would have a mounting angle of zero degrees
10
Mounting angle Measurement of the mounting angle requires a simple protractor with a plumb line The plumb line may be a straightened paper clip or any other straight piece of metal
11
Primary gaze - horizontal Telescope viewing axis Mounting angle Distance mounting angle Patient tilts head forward and sights a target at eye level through the aperture Telescope viewing axis - horizontal Telescope mounting angle = Frame angle Protractor measures frame angle
12
Distance mounting angle
13
Primary gaze - horizontal Telescope viewing axis Mounting angle Patient tilts head backwards and sights a target at eye level through the aperture Telescope viewing axis - horizontal Protractor measures frame angle Telescope mounting angle = Frame angle Near mounting angle
15
References Bailey IL. Centering high-addition spectacle lenses. Optometric Monthly. July 1979;95-100. This presentation was downloaded from www.BiOpticDriving.org www.BiOpticDriving.org
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.