R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 DEPFET sensors for a LC vertex detector (1) »DEP(leted)F(ield)E(ffect)T(ransistor) operation.

Similar presentations


Presentation on theme: "R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 DEPFET sensors for a LC vertex detector (1) »DEP(leted)F(ield)E(ffect)T(ransistor) operation."— Presentation transcript:

1 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 DEPFET sensors for a LC vertex detector (1) »DEP(leted)F(ield)E(ffect)T(ransistor) operation principles »Results of pre-tests »DEPFET prototype run »Technology, simulation and design »Wafer thinning »Concept, first results »Summary L. Andricek a, P. Fischer b, K. Heinzinger a, P. Lechner a, G. Lutz a, I. Peric b, M. Reiche c, R.H. Richter a, G. Schaller a, M. Schnecke a, F. Schopper a, H. Soltau a, L. Strüder a, J. Treis a, M. Trimpl b, J. Ulrici b, N. Wermes b a MPI Halbleiterlabor Munich b Univ. of Bonn c MPI für Mikrostrukturphysik Halle, Germany

2 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 DEPFET-Prinziple FET integrated on high ohmic n-bulk Collection of electrons within the internal gate Modulation of the FET current by the signal charge! Radiation - - - - + + + + - - ~1  m ~300  m Advantages: Amplification of the charge at the position of collection => no transfer loss Full bulk sensitivity Non structured thin entrance window (backside) Very low input capacitance => very low noise

3 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 ENC = 4.8 +/- 0.1 e - 55 Fe-spectra @ 300K Excellent noise values measured on single pixels

4 BioScope - imaging of tracer-marked bio-medical samples (P. Klein and W. Neeser) Noise: ca. 70 ENC @ 300K Slow operation (old technology) Large arrays are impossible (JFET => V P variations) Large cell size

5 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Rectangular DEPFET pixel detector MOS transistor instead of JFET A pixel size of ca. 20 x 20 µm² is achievable using 3µm minimum feature size.

6 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 DEPFET pixel matrix - Read filled cells of a row - Clear the internal gates of the row - Read empty cells Low power consumption Fast random access to specific array regions

7 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 DEPFET Technology Double poly / double aluminum process on high ohmic n - substrate along p-channel perpendicular to channel (with clear)

8 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Self aligning Technology Positions of all essential implantations are determined not by masks but by polysilicon layers shallow channel implantation - mandatory for rectangular cells (lateral channel definition) - reduces parameter variations on the wafer

9 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Technology – pre-tests Motivation oLow leakage current new technology oFirst MOS transistor parameters for the DEPFET and readout electronics design oProcess know how and design rules Pre-tests: Device test: Single poly, single Al, MOS technology on 300µm silicon + Numereous deposition, lithography and etching tests

10 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Pretest results: Diode leakage currents Reference diodes Pre-test diodes I Bulk =100pA/cm 2

11 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Linear MOS Transistors (self aligned technolgy) V GS = -4V...-7V @V B =10V L=5µmL=7µm

12 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Pixel prototype production (6“ wafer) for XEUS and LC (TESLA) Many test arrays - Circular and linear DEPFETS up to 128 x 128 pixels minimum pixel size about 30 x 30 µm² - variety of special test structures Aim: Select design options for an optimized array operation (no charge loss, high gain, low noise, good clear operation) On base of these results => production of full size sensors Production will be finished in spring

13 purpose detector format pixel size thickness noise readout time / detector / row particle tracking 1.3 x 10 cm² (x 8) 520 x 4000 pixels (x 8) 2.1 Mpix (x8) 25 µm 50 µm ~ 100 el. ENC 50 µsec 20 nsec imaging spectroscopy 7.68 x 7.68 cm² 1024 x 1024 pixels 1 Mpix 75 µm 300... 500 µm 4 el. ENC 1.2 msec 2.5 µsec

14 Active Pixel Sensor (rectangular) 2 pixels 30 x 30 µm² DEPFET L = 5 µm W = 18 µm  reduce the required read out speed by 2 doubles the number of read out channels

15 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Potential during collection - 3D Poisson equation (Poseidon) (50µm thick Si, N B =10 13 cm -3,V Back =-20V) Potential during collection - 3D Poisson equation (Poseidon) (50µm thick Si, N B =10 13 cm -3,V Back =-20V) Depth 10µm Depth 7µmDepth 4µmDepth 1µm Sources Drain External (internal) Gates n+ clear contacts Cell size 36 x 27 µm²

16 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Hiding the n + -clear contacts Depth 1µm The positive Clear pulse removes the electrons from the Internal Gate and also pushs the holes out of the deep p cover region. After returning of the clear the deep p remains negatively charges forming a shield for the signal electrons.

17 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Potential distribution during Reading Internal Gate Drain Source Back contact 2D dynamic simulation along the channel I D adjusted to 100µA (W/L =18µm/5µm) V internal Gate ca. 3V Localized charge generation simulates a hit

18 DEPFET simulation – TeSCA (2D, time dependent) hit response to a generation of 1600 electron-hole pairs

19 TeSCA (2D, time dependent) Removal of 1600 electrons from the internal gate (V Clear =15V) Simulation of the Clear mechanism Poseidon (3D Poisson equ.) Includes 3D effects => V Clear =20V

20 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Current production status Pixel array section – Design with clockable clear gate N-side view with two polysilicon layers and contact openings To do: - P-side processing - Metallization Drain Gate Clear gate Source 1 Pixel cell

21 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Processing thin detectors - the Idea -

22 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Detector thinning – first results Wafer bonding – MPI f. Festkörperstrukturphysik, Halle Wafer grinding – SICO GmbH, Jena Anisotropic etching – CiS gGmbH Erfurt, MPI Halbleiterlabor Munich Thickness of detector region : 50µm of frame : 350µm Size: 8cm x 1cm

23 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Summary oDEPFET is promising detector candidate for future HE and astrophysics experiments. Key features: low noise, full bulk sensitivity, no charge transfer loss, low power consumption, random access within an array oA new DEPFET technology (2 poly/ 2 aluminum) was developed for large arrays and high speed operation oA DEPFET Prototype production has been started with DEPFET arrays with 30 x 30 µm² pixel size (TESLA) to 75 x 75 µm² XEUS - Technology and device simulations are looking encouraging - Technological pre-tests show very good electrical parameters (leakage currents and MOS transistor characteristics) oA concept for merging the DEPFET technology with a thinning technology is proposed - thin mechanical detector samples were fabricated oFirst wafers will be finished in spring ‘03

24 R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 Processing thin detectors - Wafer bonding - 10 “ SOI” Wafer prepared by MPI für Microstrukturphysik, Halle picture from: www.mpi-halle.mpg.de Q.-Y. Tong and U. Gösele “ Semiconductor Wafer Bonding ” John Wiley & Sons, Inc. ≈1 cm/sec


Download ppt "R. H. Richter et al - VERTEX 2002 Kailua-Kona, 05.11.2002 DEPFET sensors for a LC vertex detector (1) »DEP(leted)F(ield)E(ffect)T(ransistor) operation."