Download presentation
Presentation is loading. Please wait.
1
Battery Cycler WBCS Series Introduction
April 3, 2007
2
WBCS3000 Battery Cycler
3
Strong Point Of WBCS Hardware Software
Potentiostat/Galvanostat Circuit Plug-in Module Type 8ch/Substation Independent Channel Specification Available Triple Current Range(Automatic) Expandability Software 2 Mode Selection(Cycler/Pot) User Designing Experiment Cell Connection Check Group Monitoring Function Universal Graphic Report Function File Converting
4
Strong Point Of WBCS Electrochemical Experiments Available
(Corrosion Test, Electrochemical Analysis etc.) Simple Monitor Calibration 3 Type Graph Mode Axis & Direction Changeable Calculate The Slope Text Insertion On Graph BCO Function Test Condition Change en bloc Multichannel Real Time Graph Fail Function Dual Safety Limit New File Creation During Experiment Pre-engagement Stop Function
5
Schedule File CYC(Cycler) & CYE(Potentiostat)
6
Mode Potentiostat Mode: Working(Working Sense) vs. Reference
Cycler Mode: Reference vs. Working Sense (Counter+Ref vs. Working+W.S)
7
Universal Mode For Schedule
Cycle Sampling Control Cut-Off
8
Test Info.Tap Safety Setting
9
Control Types Step Mode Scan Mode Special Mode Constant Mode STEPV
STEPI PSTEPV PSTEPI Scan Mode VSCAN ISCAN Eoc Vscan Last Vscan Special Mode ZRA Ipulse Vpulse Constant Mode CC CV CP CL C-RATE CONDV CONDI CONDR LASTV LASTI REST OCV
10
Pstep
11
Last Value Control LastV, LastI, LastVscan etc.
Prev. Step Current Step V LastV LastVscan Time If prev. step is on rest control(Rest or CondR), LastV is Eoc.
12
Cut-Off Condition FCD LCC LCD Aux V Calc V Temp dT/dt C-time L-time
Eoc Volt |dV/dt| |dI/dt| |dT/dt| Step Time Voltage Current Capacity -dV dV/dt dI/dt FCC
13
Timer Time=> Step Time C-time=> Cycle Time L-time=> Loop time
14
Percent Capacity_Cut Off
LCC(Percent Capacity Of Last Cycle Charge): Percentage Based On Previous Cycle’s Charging Capacity Value LCD(Percent Capacity Of Last Cycle Discharge): Percentage Based On Previous Cycle’s Discharging Capacity Value FCC(Percent Capacity Of First Cycle Charge): Percentage Based On The First Cycle’s Charging Capacity Value FCD(Percent Capacity Of First Cycle Discharge): Percentage Based On The First Cycle’s Discharging Capacity Value
15
Cut-Off Condition (And/Or Logic)
Priority Or Logic And Logic
16
Sampling Time Unit Input In WBCS: ####=>sec,
Or Logic Time Unit Input In WBCS: ####=>sec, AA B C => AA hr, B min C sec AA:B:C, AAHBMCS etc. AA,B,C=>digit
17
Files General Result File(RFD)-Graph Cycle Data File(EFD)-Graph
Step Data File(STD)-Graph Capacity Data File(SFD)-Report
18
Data Converting (RFD->RFX)
19
Split Data File By Cycle Number
20
Graph Option
21
Battery Test Menu
22
Control Menu
23
Virtual Control Panel
24
Start Experiment
25
Multiple Channels Control
26
Reservation Of Stop Channel
27
Strip Chart (Real Time)
28
Simple Monitor Color Sky: Charging Violet: discharging
Highest Layer Location Color Sky: Charging Violet: discharging Red: Safety/ Fail Yellow: Calibration White: Standby Grey: Idle Blue: Rest
29
Detail Monitor
30
General Graph (RFD)
31
Axis Parameters (General Graph)
32
Special Plot
33
Plot Example voltage vs. |charge/discharge capacity| voltage vs. charge/discharge cap voltage vs. abs. cap voltage vs. accum cap
34
Cycle Graph (EFD)
35
Axis Parameters (Cycle Graph)
36
EVS Using OCV, STEPV Voltage Step Graph
37
Step Graph (STD)
38
Axis Parameters (Step Graph)
39
Report
40
Back-Up Data
41
Electroanalytical Techniques
42
DC Corrosion Menu
43
Thank You !