Download presentation
Presentation is loading. Please wait.
1
AN INTRODUCTION TO THE CIRRUS PRO RANGE OF FIRE DETECTION DETECTORS
Presented by Chris Malone Export Sales Manager
3
The worlds most versatile fire detector
Contents Different Technologies Understanding Cloud Chamber Detectors Cirrus Pro Series Detector Range Applications Design Concepts Cirrus Pro Sampling Pipe Detector Configurations Cirrus Pro Series Aspirating Fire Detectors The worlds most versatile fire detector
4
The worlds most versatile fire detector
Aspirating Smoke/Fire Detectors Main Manufacturers Vesda - Laser based ‘Optical’ smoke detector Stratos - Laser based ‘Optical’ smoke detector ICAM – Laser Based ‘Optical’ smoke detector Wagner – ‘Optical’ based smoke detector Cirrus Pro Series Aspirating Fire Detectors Cirrus Pro – ‘Cloud Chamber’ fire detector The worlds most versatile fire detector
5
Cirrus Pro Series ‘Cloud Chamber’ Aspirating Fire Detectors
How do they work? What do they detect?
6
Every combustible material has a NORMAL temperature range
Understanding ‘Cloud Chamber’ detectors How does a fire start? Every combustible material has a NORMAL temperature range Temperature ‘Ignition Point’ Visible smoke (detected by ‘optical’ detection methods) Massive generation of INVISIBLE sub micron particles Cirrus Pro Series Aspirating Fire Detectors ‘Thermal Particulate Point’ The worlds most versatile fire detector
7
Understanding ‘Cloud Chamber’ detectors
What are these sub-micron particles? These are sub micron carbon particles They are mirco-meters in size They exist in normal air all the time We breath them in continuously In normal conditions only combustion generates the massive quantities that the the ‘Cloud Chamber’ can interpret as a fire condition Cirrus Pro Series Aspirating Fire Detectors The worlds most versatile fire detector
8
Understanding ‘Cloud Chamber’ detectors Sub-micron particle detection?
micron particles ? Understanding ‘Cloud Chamber’ detectors Sub-micron particle detection? In an air space 1 cm3 there are approximately 15, sub-micron particles in normal conditions i.e. (no overheat condition or fire) In the same size air space (1 cm3 ) when there is an overheat or fire condition approximately 10,000,000, sub-micron particles are produced The ‘Cloud Chamber’ detects this increase in particle generation The problem is that these particles are INVISIBLE
9
Invisible 0.0025 micron particles ?
Understanding ‘Cloud Chamber’ detectors Sub-micron particle detection? Cloud Chamber From invisible particles that cannot be measured To BIGGER visible particles that can be measured ‘Cloud Chamber’ process condenses water droplets on to all particles The enlarged particles form a cloud and the ‘Cloud Chamber’ measures the resultant cloud density Airflow containing ALL particles passes through the ‘Cloud Chamber’
10
Understanding ‘Cloud Chamber’ detectors
Why are Cloud Chambers immune to false alarms from dust ? Understanding ‘Cloud Chamber’ detectors sub micron combustion particles micron dust/smoke particles Cloud Chamber Condensate water droplets onto the sample Introduce dust into the cloud chamber Dust particles cannot provide enough cloud density to cause an alarm from the cloud chamber
11
Cirrus Pro Series Aspirating Fire Detector
Product Range
12
Cirrus Pro 100 Unique ‘cloud chamber’ detection principle
Up to 100mtrs - 25mm o/d sampling pipe Single sampling pipe port, single exhaust port ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications ‘Power Healthy’ and ‘Common Fault’ indicators Local Buzzer, Silence & Reset buttons Vast sensitivity range (incipient - heavy polluted) ‘Fixed’ or ‘Variable’ sensitivity options Detector text, Alarm text & Pipe text 3 Programmable ‘time zones’ per day ‘Transport Time’ logging feature Option for Repeat Display & Network Configuration
13
Cirrus Pro 200 Unique ‘cloud chamber’ detection principle
Up to 200mtrs - 25mm o/d sampling pipe Four sampling pipe inlet ports, single exhaust port ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications ‘Power Healthy’ and ‘Common Fault’ indicators Local Buzzer, Silence & Reset buttons Vast sensitivity range (incipient - heavy polluted) ‘Fixed’ or ‘Variable’ sensitivity options Detector text, Alarm text & Pipe text 3 Programmable ‘time zones’ per day ‘Transport Time’ logging feature Option for Repeat Display & Network Configuration
14
Cirrus Pro 200D Unique ‘cloud chamber’ detection principle
Multifunction Display & Programmer Up to 200mtrs - 25mm o/d sampling pipe Four sampling pipe inlet ports, single exhaust port ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications ‘Power Healthy’ and ‘Common Fault’ indicators Local Buzzer, Silence & Reset buttons Vast sensitivity range (incipient - heavy polluted) ‘Fixed’ or ‘Variable’ sensitivity options Detector text, Alarm text & Pipe text 3 Programmable ‘time zones’ per day ‘Transport Time’ logging feature Option for Repeat Display & Network Configuration
15
Cirrus Pro 200DSC Unique ‘cloud chamber’ detection principle
Multifunction Display & Programmer Up to 200mtrs - 25mm o/d sampling pipe Four sampling pipe inlet ports, single exhaust port ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications PER PIPE ‘Power Healthy’ and ‘Common Fault’ indicators Local Buzzer, Silence & Reset buttons Vast sensitivity range (incipient - heavy polluted) ‘Fixed’ or ‘Variable’ sensitivity options Detector text, Alarm text & Pipe text 3 Programmable ‘time zones’ per day ‘Transport Time’ logging feature Option for Repeat Display & Network Configuration
16
Cirrus Pro 200+ Unique ‘cloud chamber’ detection principle
In excess of 200mtrs - 25mm o/d sampling pipe (subject to pipe calculation program verification) Four sampling pipe inlet ports, single exhaust port ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications ‘Power Healthy’ and ‘Common Fault’ indicators Local Buzzer, Silence & Reset buttons Vast sensitivity range (incipient - heavy polluted) ‘Fixed’ or ‘Variable’ sensitivity options Detector text, Alarm text & Pipe text 3 Programmable ‘time zones’ per day ‘Transport Time’ logging feature Option for Repeat Display & Network Configuration
17
Cirrus Pro 200D+ Unique ‘cloud chamber’ detection principle
Multifunction Display & Programmer In excess of 200mtrs - 25mm o/d sampling pipe (subject to pipe calculation program verification) Four sampling pipe inlet ports, single exhaust port ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications ‘Power Healthy’ and ‘Common Fault’ indicators Local Buzzer, Silence & Reset buttons Vast sensitivity range (incipient - heavy polluted) ‘Fixed’ or ‘Variable’ sensitivity options Detector text, Alarm text & Pipe text 3 Programmable ‘time zones’ per day ‘Transport Time’ logging feature Option for Repeat Display & Network Configuration
18
Cirrus Pro 200DSC+ Unique ‘cloud chamber’ detection principle
Multifunction Display & Programmer In excess of 200mtrs - 25mm o/d sampling pipe (subject to pipe calculation program verification) Four sampling pipe inlet ports, single exhaust pipe port ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications PER PIPE ‘Power Healthy’ and ‘Common Fault’ indicators Local Buzzer, Silence & Reset buttons Vast sensitivity range (incipient - heavy polluted) ‘Fixed’ or ‘Variable’ sensitivity options Detector text, Alarm text & Pipe text 3 Programmable ‘time zones’ per day ‘Transport Time’ logging feature Option for Repeat Display & Network Configuration
19
Cirrus Pro RDP (Remote Display Programmer)
Multifunction Display & Programmer May be assigned to individual Cirrus Pro detector May be assigned to a network of Cirrus Pro detectors ‘Network Status’ indication ‘Power Healthy’ and ‘Common Fault’ indicators Global Network - Silence & Reset buttons Local Buzzer with mute facility Remote access/control to any networked Cirrus Pro detector Can provide detector text, alarm text & pipe text per device Can provide ‘Real Time’ and ‘Historic’ graph data per device
20
Categories High Sensitive Applications
General Sensitivity Applications Harsh Environment Applications Special Risk Applications Sensitive Applications
21
High Sensitive applications include….
Data Storage Control Rooms Computer Rooms
22
General Sensitive applications include
Roof Voids Warehousing Atriums
23
Harsh Environment applications include
Cold Storage Specialist Production Food Production
24
Special Risk applications include
Cabinet Protection Rotunda Areas Test Rooms
25
Sensitive Applications include
Historic Buildings High Ceilings Ornate Ceilings
26
The worlds most versatile fire detector
Cirrus Pro Series Aspirating Fire Detectors The worlds most versatile fire detector
27
CIRRUS PRO TCP-IP CONNECTIONS
30
The worlds most versatile fire detector
Köszönöm THE END Cirrus Pro Series Aspirating Fire Detectors The worlds most versatile fire detector