MWAVES Wave Sampling Nobska Development, Inc. Albert J. Williams 3 rd Archie Todd Morrison III
2
Talk Outline Deployment and Sampling Guidelines Designing a Deployment Schedule Deploying and Recovering MAVS-3 MAVSoft and MAVSTerm Data Recovery and Unpacking MAVSPack Data Processing - Case Studies Time-Series MWAVES – Directional Wave Spectra
3
Deployment Guidelines Wave measurements should be made from a fixed platform Small tripods with weighted foot pads Orient the sensor vertically For best results, mount the sensor No more than 10 – 15 meters below the surface Consider wave frequencies and amplitudes of interest MAVS will return clean results from up to 30 meters below the surface under some conditions At least 0.75 – 1.0 meter above the bottom 1.5 – 2.0 meters is preferred
4
Sampling Guidelines 2 – 4 Hz measurement frequency 1 measurement per sample (no averaging) 2048 – 8192 samples per burst 10 – 45 minute burst duration Set interval between bursts to capture the time scales over which the wave field is changing East – North - Up velocity frame Observe memory and power constraints
5
References and Examples See the MWAVES manual for examples and a selection of published references Many papers are available for download from our web site - www.nobska.net The Nobska CD-ROM contains the manual and many of the papers