Presentation is loading. Please wait.

Presentation is loading. Please wait.

V andal E ngineers C reating C old T rap for R eactor.

Similar presentations


Presentation on theme: "V andal E ngineers C reating C old T rap for R eactor."— Presentation transcript:

1 V andal E ngineers C reating C old T rap for R eactor

2  Test Section  Axiomatic  Prototype Design  Components  Cold Trap  Axiomatic  Patent Synopsis  “Active” Conceptual Designs  Action Items

3 FUNCTIONAL REQUIREMENTS  Measure Velocity  Measure Temperature  Interfaces with test loop DESIGN PARAMETERS  Acoustic Transducer measurement  Temperature controlled test section  Meets Argonne Standards and uses existing fittings Axiomatic Design

4  Integration  Support  Diffuser  Acoustical Measurement Transducers

5 ItemQuantityPrice 6LV-8-VCR-3S-8TB72$2 / each SS-8-VCR-12$2 / each 8-VCR-2-VS2$1 / each 304 SS Sheet12” X 36”$66.73

6 Model STH051-080 627 Watt ½” x 8’ 120 A $71.00/each Oversized to maintain incoming flow at 500 o C Insulated to reduce waste heat

7 The test section will be wrapped with a 25mm thick Alumina-Silicate blanket (or similar insulator). K=.105W/m*K Very high temperature rating. $8.00/ft (1” thick x24” wide)

8 Sodium Temperature Controller Omega® CN740 Series Simple on/off control at set temperature Displays both the actual and set temperature Compatible with K thermal couples Cost—$88.00 Limit Controller for Heaters Omega® CN700 Series Option if over heating is a concern High or Low Limit Compatible with K type Thermocouples Cost—$97.00

9  Type K Thermocouple  Rated to 980 o C continuous service  Multiple termination connections  $48.00/each XCIB series thermocouples (omega.com)

10 Partsqty$ / eachtotal $ Swagelok fittings224 Swagelok Gland224 304 S.S. Sheet166.73 Ribbon Heater171 Insulation3824 Temperature controller188 Limit Controller197 Thermocouples348144 GRAND TOTAL= 498.73

11 FUNCTIONAL REQUIREMENTS  Remove Particulates  Add Particulates  Interfaces with test loop DESIGN PARAMETERS  Cold Trap/Cold Finger  Release Mechanism  Defined Fittings and Locations Axiomatic Design

12 ProsCons Majority of particulate collects on the bottom and sides of 22 making them easier to remove Particulates are spread out over large area All sodium flow passes through a filter

13 ProsCons All sodium particulates are localized in the filters Sodium is trapped in two separate filters Complex to construct

14 Temperature Control Passive heating (turn off cooling) Active heating (heat w/ external source, e.g. heat exchanger from test section) Vibration Stirring Scraping Some combination of the above

15

16

17  Deliverables  Cold Trap prototype conceptualized  Test section prototype construction  “Marching orders”


Download ppt "V andal E ngineers C reating C old T rap for R eactor."