1
Sustained Compliance Workshop - Anchorage, AK September 23-24, 2010 Eric Burg Kenai Peninsula & Southeast Alaska – Compliance & Monitoring Section DEC Drinking Water Program Eric.Burg@alaska.gov / (907) 262-5210 ext. 246 1
2
Presentation Outline Introduction Elements of an Operator Report & Reporting Requirements Common Reporting Errors and Issues Summary 2
3
Introduction 3
4
Introduction Continued Monthly Operator Reports serve several functions Primary function is it provides a way to track effectiveness of the filtration and disinfection system. Provides a record of daily operational readings. A means of reporting to DEC that all regulatory requirements have been met. 4
5
Introduction Continued Different Types of Operator Reports Conventional or Direct Filtration 3 or more filters Less than 3 filters Alternate Filtration, Slow Sand, or Diatomaceous Earth Standard report Reduced Monitoring 5
6
Introduction Continued System Information & Daily Readings Combined Filter and Disinfection Performance 6
7
Introduction Continued Continuous Monitoring SummaryCFE or IFE Turbidity Exceedance Report 7
8
Presentation Outline Introduction Elements of an Operator Report & Reporting Requirements Common Reporting Errors and Issues Summary 8
9
Elements of an Operator Report Page 1 of Operator Report System Information and Daily Readings Page System Information Public Water System (PWS) Name PWS ID # Address Phone # Month & Year of report Turbidity Entry Point Chlorine Filter Fluoride Operator Signature Line 9
10
10
11
Elements of an Operator Report Page 1 of Operator Report Continued 11
12
Elements of an Operator Report Page 1 of Operator Report Continued System Information Public Water System (PWS) Name PWS ID # Address Phone # Month & Year of report Turbidity Entry Point Chlorine Filter Fluoride Operator Signature Line 12
13
13
14
14
15
Turbidity Reporting Requirements Combined filter effluent (CFE) turbidity measurements Taken after the point where all individual filter effluents combine. Turbidity measurements are taken from grab samples or online turbidimeter recordings taken at four hour intervals. Recorded on first page of operator report. 15
16
Turbidity Reporting Requirements Continued CFE turbidity requirements 95% of all CFE turbidity measurements taken during the month must be less than or equal to: 0.3 NTU for Conventional and Direct filtration plants 1.49 NTU for Alternative, Slow Sand, & Diatomaceous Earth plants 16
17
Turbidity Reporting Requirements Continued Maximum CFE Turbidity limits: 1.49 NTU for Conventional and Direct plants 5 NTU for Alternative, Slow Sand, & Diatomaceous Earth plants Must notify DEC within 24 hours if maximum CFE limit is exceeded. Document on Page 2 of operator report. 17
18
Elements of an Operator Report Page 1 of Operator Report Continued System Information Public Water System (PWS) Name PWS ID # Address Phone # Month & Year of report Turbidity Entry Point Chlorine Filter Fluoride Operator Signature Line 18
19
19
20
20
21
Entry Point Chlorine Reporting Requirements Residual readings collected daily at entry point to the distribution system Sampling frequency is based on population #’s 500 or fewer = 1 sample/day 501 – 1,000 = 2 samples/day 1,001 – 2,500 = 3 samples/day 2,501 – 3,300 = 4 samples/day 3,301 or greater and all other systems that monitor continuously Must report lowest value each day 21
22
Entry Point Chlorine Reporting Requirements Continued Entry point chlorine residuals must be at least 0.2 mg/L at all times. Some systems may have a higher entry point chlorine concentration requirement. To meet contact time requirements. Flow Characteristics Turbidity levels 22
23
Entry Point Chlorine Reporting Requirements Continued If entry point residual drops below 0.2 mg/L Contact DEC soon as possible - no later than the end of the next business day. Date and duration below 0.2 mg/L must be recorded on page 2 of the operator report (Entry Point Disinfection Performance Criteria). DEC will review if treatment technique violation was generated. If chlorine level is raised above 0.2 mg/L within 4 hours, no violation will be assessed. 23
24
Elements of an Operator Report Page 1 of Operator Report Continued System Information Public Water System (PWS) Name PWS ID # Address Phone # Month & Year of report Turbidity Entry Point Chlorine Filter Fluoride Operator Signature Line 24
25
25
26
26
27
Filter Reporting Requirements Did you filter & produce water during the day? Check “Yes” or “No” 27
28
Elements of an Operator Report Page 1 of Operator Report Continued System Information Public Water System (PWS) Name PWS ID # Address Phone # Month & Year of report Turbidity Entry Point Chlorine Filter Fluoride Operator Signature Line 28
29
29
30
30
31
Fluoride Reporting Requirements Measured daily at the entry point to the distribution system. Entry point fluoride residual must not exceed 2.0 mg/L. Notify DEC within 24 hours if fluoride residual is equal to or greater than 2.0 mg/L. 31
32
Fluoride Reporting Requirements Continued On the first day that the fluoride residual is > 2.0 mg/L, a confirmation sample must be collected and sent to a certified laboratory to verify field test results. Public Notice requirements will be based upon certified laboratory sample results. Circumstances may dictate otherwise. 32
33
Elements of an Operator Report Page 1 of Operator Report Continued System Information Public Water System (PWS) Name PWS ID # Address Phone # Month & Year of report Turbidity Entry Point Chlorine Filter Fluoride Operator Signature Line 33
34
34
35
Elements of an Operator Report Page 1 of Operator Report Continued 35
36
Operator Signature Requirement Must be signed in accordance with 18 AAC 80.1900 The owner or operator shall certify by signature that the information and data contained in a report required to be filed under this chapter are true and correct to the best of the owner’s or operator’s knowledge. 36
37
Elements of an Operator Report Page 2 of Operator Report Combined Filter and Disinfection Performance Page Combined Filter Performance Criteria Entry Point Disinfection Performance Criteria Distribution System Disinfection Residual Criteria 37
38
38
39
Elements of an Operator Report Page 2 of Operator Report continued Combined Filter Performance Criteria Entry Point Disinfection Performance Criteria Distribution System Disinfection Residual Criteria 39
40
40
41
Combined Filter Performance Criteria 41
42
Combined Filter Performance Criteria Continued 42
43
Combined Filter Performance Criteria 43
44
Elements of an Operator Report Page 2 of Operator Report continued Combined Filter Performance Criteria Entry Point Disinfection Performance Criteria Distribution System Disinfection Residual Criteria 44
45
45
46
Entry Point Disinfection Performance Criteria 46
47
Elements of an Operator Report Page 2 of Operator Report continued Combined Filter Performance Criteria Entry Point Disinfection Performance Criteria Distribution System Disinfection Residual Criteria 47
48
48
49
Distribution System Disinfectant Residual Criteria 49
50
Elements of an Operator Report Page 3 of Operator Report Continuous Monitoring Summary Page Conventional and Direct Filtration systems only Combined filter effluent monitoring – less than 3 filters Individual filter effluent monitoring – 3 or more filters 50
51
51
52
52
53
Presentation Outline Introduction Elements of an Operator Report & Reporting Requirements Common Reporting Errors and Issues Summary 53
54
Common Reporting Errors and Issues Distribution chlorine residuals Not collected at the same time and place as total coliform sample. Not recorded on operator report. Readings written on total coliform sample paper work may not always be reported to us by the lab. Missed same time and place chlorine residual results in two violations Distribution system residual requirement Maximum Residual Disinfectant Residual (MRDL) requirement 54
55
Common Reporting Errors and Issues Late submittals Reports due to DEC by the 10 th of the following month. Late reporting violation Missing operator signature & date Required by 18 AAC 80.1900. Late reporting violation if amended report not received by 10 th. 55
56
Common Reporting Errors and Issues Not submitting or filling out all the required pages Not notifying DEC when required Turbidity exceedances Low entry point chlorine levels Month & Year of report not recorded 56
57
Common Reporting Errors and Issues Illegible handwriting Decimal point errors 57
58
Presentation Outline Introduction Elements of an Operator Report & Reporting Requirements Common Reporting Errors and Issues Summary 58
59
Summary Operator reports are an important and useful tool to keep track of your system performance. Turbidity readings CFE’s for all system types. IFE verification for Conventional & Direct systems. Chlorine readings Entry point Distribution Fluoride readings Operational issues or anomalies Satisfies regulatory reporting requirements 59
60
Summary Continued Where to Get Operator Report Forms? On the web at: http://dec.alaska.gov/eh/dw/publications/forms.html From the DEC office that covers your system. 60
61
Summary Continued Where to Send Your Report? Anchorage Office 555 Cordova Street Anchorage, AK 99501 Toll Free: 1-866-956-7656 Fax: 269-7650 DEC.DWData.Anchorage@alaska.gov Fairbanks Office 610 University Avenue Fairbanks, AK 99709-3643 Toll Free: 1-800-770-2137 Fax: 451-2188 DEC.DWData.Fairbanks@alaska.gov Soldotna Office 43335 Kalifornsky Beach Rd., Suite 11 Soldotna, AK 99669-9792 Phone: (907) 262-5210 Fax: 262-2294 DEC.DWData.Kenai@alaska.gov DEC.DWData.Juneau@alaska.gov Wasilla Office 1700 E. Bogard Rd., Bldg. B Suite 103 Wasilla, AK 99654 Phone: (907) 376-1850 Fax: 376-2382 DEC.DWData.Wasilla@alaska.gov 61