Presentation is loading. Please wait.

Presentation is loading. Please wait.

Plasma E- Measurement Brian DeHerrera John Purcell Jaber Assiri.

Similar presentations


Presentation on theme: "Plasma E- Measurement Brian DeHerrera John Purcell Jaber Assiri."— Presentation transcript:

1 Plasma E- Measurement Brian DeHerrera John Purcell Jaber Assiri

2 Outline Introduction ◦Purpose ◦Problems HFSS Simulation Current Design Voltage Divider Future Work & budget Conclusion

3 Purpose Create reliable current and voltage sensing equipment to work in common plasma ranges ◦>500V ◦>10MHz Create more reliable plasma for experiments ◦Control line impedance ◦Measure waveform being transmitted to plasma probe

4 Plasma System Signal Generator Amplifier Z- Scan Matching Network Plasma Probe

5 Problems No commercially available probes ◦Can meet some specifications, but not both frequency and desired voltage Not trivial to create homebrew probe ◦Needs to be high impedance ◦Parasitic

6

7

8 HFSS Simulation Draw Model Assign Boundary Conditions Assign Excitation Ports (inputs) Analyze Generate Reports

9 Draw Model

10 Freq Response

11

12 Current Design: Coax Modeled design off of AE’s Z-Scan Benefits: Parasitic are minimized Sensor can be added in-line with plasma system Concerns: EMI design: both shielding outside noise and reducing leakage Semi-complicated design ◦Need to machine parts

13 Current Design: Coax Signal Generator Amplifier Z- Scan Matching Network COAX device Plasma Probe

14 Current Design: Coax

15 Voltage Divider Why a V-D?

16 Voltage Divider Conditions: ◦R 1 +R 2 >= 2M Ohm & C 1 +C 2 <10p F Signal Generator Amplifier Z-Scan Matching Network Plas ma Prob e

17 Voltage Divider Conditions: ◦R 1 *C 1 =R 2 *C 2  If (R 1 *C 1 )> (R 2 * C 2 )

18 Voltage Divider Conditions: ◦R 1 *C 1 =R 2 *C 2  If (R 1 *C 1 )<(R 2 * C 2 )

19 Voltage Divider Conditions: ◦R 1 *C 1 =R 2 *C 2

20 Voltage Divider From: ◦R 1 +R 2 >= 2M Ohm & C 1 +C 2 <10pF & ◦R 1 *C 1 =R 2 *C 2 Therefore: ◦R 1 = 10M ohm, R 2 = 100k ohm ◦C 1 =.1pF, C 2 = 10pF

21 Future Work DateWhat will be doneCost 1/30/2010Finish the designs we have $120 2/1/2010Find more sensitive Current Transformer & probes 2/10/2010Getting some readings 2/15/2010Change the important changes in the designs $10-$20 3/1/2010Getting some results 3/30/2010Start to do the final designs $10-$50

22 Conclusion Purposes & problems HFSS Simulation Current Design Voltage Divider Future Work & budget

23 Thank you Questions ??


Download ppt "Plasma E- Measurement Brian DeHerrera John Purcell Jaber Assiri."