Download presentation
1
SOLID/ SLUDGE MANAGEMENT
2
Solid and Biosolids SOLIDS AND BIOSOLIDS
The largest waste (in volume) Form:liquid or semisolid liquid ( % solid) Term biosolid: WW solid are organic product that can be used beneficially after treatment (WEF 1998) Term sludge: used only before achieve beneficial use criteria Term solid: if uncertain criteria
3
Solids Sources
4
Schematics diagram of conventional activated sludge
5
Characteristics and quantities of waste sludge
To estimates the raw solids removed by plain sedimentation: Where Wp = raw primary sludge solids (g/d) f = fraction of SS removed in primary settling SS = suspended solids in unsettled ww (g/d)
6
Characteristics and quantities of waste sludge
To estimates the secondary treatment solids generated: Where Ws = biological sludge solids (g/d) K = fraction of applied BOD that appears as excess biological solid. K depend on F/M ratio or bacteria growth rate. BOD = BOD in applied ww after primary sedimentation(g/d) Total sludge solids production in conventional treatment plant with primary and secondary treatment, Wps = Wp+Ws
7
Characteristics and quantities of waste sludge
Volume of wet sludge, V (Liter) Where W = weight of dry solids, kg s = solids content p = water content
8
Example A ww with 200 mg/L BOD and 220 mg/L SS is processed in trickling filter plant. K=0.34. Assuming 50% SS removal and 35% BOD removal from primary clarifier: Estimates the quantities of sludge solids from primary and secondary biological filtration per cubic meter of ww treated. Calculate volume of wet sludge from final clarifier and combined with solid content 5%.
9
SLUDGE COMPOSITION Predominantly water Micro-organisms
Viruses, pathogens, germs in general Organic particles, heavily bio-degradable Organic compounds, inert, adsorpted to sludge flocs Heavy metals Micro-pollutants, pharmaceuticals, endocrine disrupters All non-degraded compounds extracted from wastewater are found in the sludge
10
Sludge characteristics
11
SLUDGE TREATMENT GOAL Volume reduction Elimination of pathogenic germs
Thickening Dewatering Volume reduction If used in agriculture as fertiliser or compost Elimination of pathogenic germs Gas production Reduction of dry content and odour Improvement of dewatering Stabilization of organic substances Nutrients, fertilizer Humus Biogas Recycling of substances
12
Sludge treatment alternatives
Eckenfelder & Santhanam (1981)
13
Sludge processing
14
thickening
15
Sludge thickening Why is it important?
Used to increase solid content of sludge by removing removing a portion of liquid fraction Usually accomplished by physical means; e.g settling, flotation, centrifugation, gravity belt and rotary drum. Why is it important? Beneficial to the subsequent treatment processes from the following stand points: Capasity of tanks and equipment required Quantity of chemical required for sludge conditioning Amount of heat (in digester) and fuel required for heat drying and incineration
16
Sludge thickening 2. Cost reduction -small pipe size and pumping cost 3. Liquid sludge can be transported easily In designing thickening facility, it is important to: Provide adequate capasity to meet peak demand Prevent septicity, with its attendant odor problem.
17
Gravity belt thickener
18
Schematic diagram : CENTRIFUGAL THICKENING
19
Example Estimate the sludge volume reduction when the sludge is thickened from 4% to 7% solids concentration. The daily sludge production is 100 m3. Solution: Calculate amount of dry sludge produced Calculate volume in 7% solid content Calculate percentage of sludge volume reduction Ans: 42.9%
20
EXAMPLE: Primary sludge containing trickling filter humus is gravity thickened in circular tank with 3.6m dia. and 3 m side water depth. The applied sludge is 10 m3/d with 4.5% solids and the thickened sludge withdrawn is 5 m3/d at 7.5% solids. The blanket of consolidating sludge in the tank has a depth of 1 m. For odour control, 170 m3/d of treated wastewater is pumped to the tank along with sludge to increase overflow rate. Calculate: Solid loading % solid captured Overflow rate Solid retention time
21
stabilization
22
STABILIZATION Not suitable for survival of microb
Stabilization process of sludges for volume reduction, production of usable gas (methane), and improving the dewaterability of sludge Solids and biosolids (sludge produced from primary or secondary treatment) are stabilized to: - reduce pathogens - eliminate offensive odors - inhibit, reduce, or eliminate the potential for putrefaction (decay, decompose of organic matters). Therefore, stabilization involves the reduction of volatile content and addition of chemicals to solid and biosolid and… Not suitable for survival of microb
23
Alkaline Stabilization
Aerobic digestion Anaerobic digestion Composting Alkaline Stabilization
24
Gravity Thickener Inflow Scum scimmer Sludge liquor Picket fence
Thickened sludge
25
Thickening by Flotation
26
Flotation unit
27
Processes in digester Anaerobic degradation
Degradation of organic substances of app. 50% Biogas production: 63% CH4 (Methane) 35% CO2 2% other gases (N2, H2, H2S) electricity and heating Organic nitrogen is converged to NH4+ N-loading of WWTP
28
Characteristic values of digester
Mean residence time of sludge Small units, badly mixed < 30 d Medium size units with mixing 20 d Large plants with mixing 12 – 16 d Biogas production related to degradation of organic substances 0.9 m3 / kg VSSdegr. Degradation of organic substances 40 – 55%
29
Simultaneous aerobic sludge stabilisation
No primary clarifier no primary sludge High sludge age SRT, app. 25 d Activated sludge tank is larger than that combined with an anaerobic sludge stabilisation No biogas production Possibly combined with storage or thickener unit Stable and simple operation
30
Comparison between anaerobic and aerobic processes
Anaerobic Aerobic Organic loading rate High loading rates:10-40 kg COD/m3-day Low loading rates: kg COD/m3-day (for high rate reactors, e.g. AF,UASB, E/FBR) (for activated sludge process) Biomass yield Low biomass yield: kg VSS/kg COD High biomass yield: kg VSS/kg COD (biomass yield is not constant but depends on types of substrates metabolized) (biomass yield is fairly constant irrespective of types of substrates metabolized) Specific substrate utilization rate High rate: kg COD/kg VSS-day Low rate: kg COD/kg VSS-day Start-up time Long start-up: 1-2 months for mesophilic : 2-3 months for thermophilic Short start-up: 1-2 weeks
31
Comparison between anaerobic and aerobic processes
Anaerobic Aerobic SRT Longer SRT is essential to retain the slow growing methanogens within the reactor Microbiology Anaerobic processes involve multi-step chemical conversions and a diverse group of microorganisms degrade the organic matter in a sequential order Aerobic process is mainly a one-species phenomenon, except for nutrient-removal processes Environmental factors The process is highly susceptible to changes in environmental conditions SRT of 4-10 days is enough for the activated sludge process The process is more robust to changing environmental conditions
32
ANAEROBIC SLUDGE DIGESTION
33
Sludge Digestion: Anaerobic
37
Dewatering Drying
38
Volume reduction Water content in stabilised sludge > 95% !
Reduction of water content and volume Sludge volume With water content non-linear relation!
39
Volume reduction 12 Sludge treatment Urban Water Systems
40
Dewatering Unit Operation Method W DS Decanter Continuous Centrifuge
Conditioning with flocculation agents (poly-electrolytes) for efficient dewatering Unit Operation Method W DS Decanter Continuous Centrifuge > 0.7 < 0.3 Chamber filter press (large plants) Batch-wise Hydraulic pressure through plates in water-tight chambers > 0.6 ≤ 0.4 Belt filter press (small plants) continuous Pressed between two filter belts around staggered rollers > 0.7 ≤ 0.3
41
Centrifuge
42
Filter Press
43
Filter Press
44
Drying bed Dimensioning W 0.55 (Imhoff, 1990) Plant type
Thin sludge layer (< 20 cm) Sand layer as drainage and filter layer Sludge is first dewatered by drainage then air-dried through evaporation Applicable for small plants Dimensioning W 0.55 (Imhoff, 1990) Plant type Specific surface Only mechanical treatment 13 PE/m2 Trickling filter 6 PE/m2 Activated sludge plant 4 PE/m2
45
Filling the drying bed with sludge
Starting the drying process
46
Drying Vaporisation of water content Partial drying W 0.3 – 0.4
Full drying W down to < 0.1 Contact drying over heated areas Drying by convection through hot air counter-current inlet app. 600°C, outlet app. 300°C (Imhoff, 1999) For large plants Disposal is critical: fire, dust explosion In granulate form as fertiliser
47
Sludge disposal/reuse
48
Use in agriculture Sludge treatment Fertiliser* Liquid sludge
Recycling of nutrients, from stabilised sludge Sludge treatment Fertiliser* Liquid sludge P- and N-fertiliser Dewatered sludge P-fertiliser, N as storage product Dried sludge P-fertiliser * Limit re. over-fertilisation Problems Acceptance Heavy metals Micro-pollutants, pharmaceuticals, endocrine disruptors
49
Composting Aerobic biological degradation of organic substances
Prerequisites Stabilisation Dewatering Hygienisation Approach Structure means: straw, wood, saw dust, wood chips Mixture app. 1:1 Water content app. 0,65 Requirements are more demanding than for sludge use as fertiliser!
50
Incineration Use of energy content, but not of nutrients
Mono incineration (sludge exclusively) Calorific value of sludge high enough no biogas use before, no stabilisation Water content not minimised (no full drying) Fluidised bed incinerator, incineration at 800 – 950°C in fluidised sand bed Expensive! Co- incineration In coal power station In solid waste incinerators In cement production, ash is bounded to cement
51
Fluidized bed sludge incineration
52
Thank you