Digital Conversion of Single-Use Camera Ranging Lab Michael Spaeth SUC Tech Center Eastman Kodak Company
2
Ranging Lab
3
Problems with Ranging Lab Negatives are read via microscope –Tiring for observer Human differences –What you see as a line pair, I may not Red tint of color AgX negative
4
Digital Method - Theory Digitally sample images –Whether with CCD array or film scanner Run images through a slanted-edge test to find MTF Compare MTF’s to find ‘best’ focus
5
Slanted-Edge Algorithm Slanted-Edge software www.pima.net/standards/iso/tc42/wg18/wg18__sfr_matlab_page.htm Written in Matlab Needs high contrast in target Needed to be converted to IDL
6
Slanted-Edge Test - Matlab
7
IDL Conversion Test
8
Ranging Lab Program Loops Slanted-Edge Analysis Compares MTF values to determine ‘best’ focus
9
Ranging Lab Program Demo
10
Problems With Method Inconsistant –Does not return same value each time through –Possible Reason – low contrast in images, creating high error in MTF calculation –Possible Solution – use target with higher contrast alter image to raise contrast
11
Problems With Method All the plots are the same –Possible Reason – multiple systems influencing system MTF –Possible Solutions – Analyze all systems other than optics and subtract MTF for these systems Reduce number of systems in process