Download presentation
Presentation is loading. Please wait.
1
OLYMPUS Collaboration Meeting Luminosity Monitor Symmetric Möller/Bhabha Calorimeter David Rodríguez Piñeiro HIM / Mainz University OLYMPUS Collaboration Meeting DESY 26. 04. 2011
2
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting2 1.- New Beam Pipe Design 2.- New SYMB Design 3.- Main Support 4.- Interferences 5.- Summary
3
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting3 1.– New Beam Pipe Design
4
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting4 Cone pipe with SYMB windows: Difficult and expensive to manufacture Traditional design
5
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting5 Windows shorter Cone (due to Wakefield suppressor) inside the beam pipe
6
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting6 2.– New SYMB Design
7
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting7 Shifted ~350 mm upstream Adapted to the new enviroment Collimator and Lead Wall not aligned Boxes move away from the beam in diagonal Alignment system reordered
8
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting8 In the new position
9
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting9 Safety Factor: SF Total Displacement: TD SF > 7 TD < 0,05 mm SF > 8 TD < 0,04 mm SF> 6 TD: 0,0007 mm
10
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting10 Hallo Counter Further check
11
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting11 3.– Main Support
12
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting12 Will fit with this shape Will be made out of standard aluminum profiles Adaptad to the new enviroment
13
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting13 Longer in Z Still laying on the tubular supporting beams Due to interferences it will be mounted in place
14
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting14 4.– Interferences
15
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting15 SYMB OLYMPUS No clash detected Just 0 contact on the tubular supporting beams
16
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting16 Top View MWPC ToF Frame Beam Pipe Coils Frame
17
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting17 Tight clearances, but feasible
18
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting18 Mounted in place Optimized design to avoid overlapping parts
19
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting19 Cables to the ceiling? Tubular support attached to ToF frame Flasher box? Flasher box
20
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting20 New beam pipe design => New SYMB design New position: ~350 mm upstream Not interference with other subsystems (Hallo Counter study) Attached to the tubular supporting beams (longer in Z towards the beam) Summary
21
Symmetric Möller/Bhabha 26/04/2011David Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting21 Personal Contact: d.rodriguezpineiro@gsi.de Tel: +49 (0) 6159171/1634 web.mit.edu/OLYMPUS Thank you! Frank Maas Sebastian Baunack Dmitry Khaneft Boris Gläser Eric Göbel Yue Ma Roberto Pérez
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.