CDAE 170 Solar Building Strategies Class #7 Oct. 18, 2003 Gary Flomenhoft BSME, MAPP, CEE Research Associate Gund Institute, SNR
2
Review of Glazing-Chiras Window glazing: South glass: 7-12% of floor footage North glass: <=4% East glass: <=4% West glass: <=2%
3
Direct Gain Principles-Kachadorian 1.East, South and West glass should be 10-20% of total exterior heated wall area 2.Peak supplied February day increase in solar slab temperature should be 8 degrees.
5
Review of Indirect Gain Thermal Mass-Chiras (Thermal storage or Trombe wall) Vented Trombe wall
6
Sunspace
8
Skylight
10
OVERHANG
11
OVERHANG p.107 (www.susdesign.com/overhang) L = Length of Projection H = Height of window opening L = H / F44º latitude: F=2.0-2.7
12
SHADING
13
Vapor Barrier
19
INSULATION VALUES
22
Review of Direct Gain Thermal Mass-Chiras Sun-tempered = 7% of floor footage. Incidental mass takes care of it (sheetrock, framing, furniture) >7% glazing needs extra mass. MASS THICKNESS 4-6” DIRECT FLOOR MASS: Each square foot of glazing over 7% x 5.5 or INDIRECT FLOOR MASS: glazing >7%sq.ft. x 40 or DIRECT or INDIRECT WALL MASS* in solar room: glazing >7% x 8.3 *Not everyone agrees
23
Review of Indirect Gain Thermal Mass-Chiras (Thermal storage or Trombe wall) MATLDENSITYTHICKNESS CONCRETE1408-24 CONCRETE BLOCKS 1307-8 CLAY BRICKS 1207-16 LT WEIGHT CONCRETE MASONRY 1106-12 ADOBE1006-12
24