Download presentation
2
MEMORY MODE The HAAS Control Series
3
SLIDE LEGEND To advance through the presentation click
PRESS THREE TIMES TO GET TO THIS PAGE (Continued on next slide) Note: ACTIONS To advance through the presentation click on your left mouse button or press <ENTER>. To exit press <ESC>. KEYS INSTRUCTIONS INFORMATION OTHER INFORMATION
4
MEMORY MODE This module is intended to provide you with a familiarization of the Memory Mode on the Haas Control
5
Here is where you find the Memory Buttons
There are eight different keys under the “Display” area. Some of these have several functions or screens. Apr-17
6
Memory Buttons MEMORY: SINGLE BLOCK: DRY RUN: OPTIONAL STOP: BLOCK DELETE: Pressing the memory button on the control will display the current program for running when you press <CYCLE START>. The current program is the one that has been selected in LIST PROGRAMS.
7
The selected program is ready to run.
Memory Button: MEMORY Button: The selected program is ready to run. Press <CYCLE START> PROGRAM (MEM) O N00000 O (MILL LAB PROG 1) ; G01 Z F7. ; G01 X Y ; G01 X ; G01 X Y ; G01 X ; G01 X ; G01 X Y ; G03 X Y R0.02 ; F4 FOR PROG REVIEW
8
Single Block Button: SINGLE BLOCK Button: Used like a toggle switch.
The control will execute one block of program then stop; every press of <CYCLE START> will execute one more block. With Setting 104: Jog Handle to Single Block ON Press <CYCLE START> Then rotate the Jog Handle CCW to run the program. Each click of the handle will execute 1 block. CW = Feed Hold PROGRAM (MEM) O N00000 O (MILL LAB PROG 1) ; G01 Z F7. ; G01 X Y ; G01 X ; G01 X Y ; G01 X ; G01 X ; G01 X Y ; G03 X Y R0.02 ; F4 FOR PROG REVIEW SINGBK Excellent for checking out your program when in Graphics Mode
9
Dry Run Button: DRY RUN Button: Used in Memory or MDI mode.
Used to check a program using reduced speeds and feeds. All rapids and feed rates are run at the rate selected with the JOG speed keys. Press Select the speed. <HAND CNTL SPIN> Adjust with Jog Handle PROGRAM (MEM) O N00000 G01 Z F7. ; G01 X Y ; G01 X ; G01 X Y ; G01 X ; G01 X ; G01 X Y ; G03 X Y R0.02 ; DRY RUN SPEED 1. O (MILL LAB PROG 1) ; DRYRUN
10
Optional Stop Button: OPTIONAL STOP Button:
When an M01 command is encountered in the program, then a program stop will be executed. Press <CYCLE START> to continue. PROGRAM (MEM) O N00000 G01 Z F7. ; G01 X Y ; G01 X ; G01 X Y ; G01 X ; M01 G01 X (Optional Stop); G01 X ; G01 X Y ; G03 X Y R0.02 ; F4 FOR PROG REVIEW O (MILL LAB PROG 1) ; OPTSTP
11
Block Delete Button: BLOCK DELETE Button:
When a program block begins with a slash (/) it will be ignored (i.e., that program block will not execute). PROGRAM (MEM) O N00000 G01 Z F7. ; G01 X Y ; G01 X ; G01 X Y ; G01 X ; /G01 X (Block Delete) ; G01 X ; G01 X Y ; G03 X Y R0.02 ; F4 FOR PROG REVIEW O (MILL LAB PROG 1) ; BLKDEL
12
Prepared by Haas Automation Training Department Oxnard, CA 93030