Track Fitting and Comparator Results Emu meeting @ UC Davis Feb. 26, 2005 Yangheng Zheng University of California, Los Angeles Motivation & Introduction Results
2
02/26/2005 Emu meeting @ UC Davis 2Motivations Check output from comparator chips (for both ME2/2 and ME1/1) Get familiar with Stan’s track-fitting utility package (TrackFnd) Test the unpacking software (ORCA/EmuDAQ) for test-beam 2004 data Look at ME1/1 data from TB2004
3
02/26/2005 Emu meeting @ UC Davis 3 Stan’s Track Fitting Framework Pedestal Subtraction Precision Sampling Time buckeye shaping Cross Talk is a function of t s (capacitative+slightly resistive coupling between adjacent strips) lookup table Cathode Noise Correlation unfired events Fitting Gatti distribution hit position / each layer Track Finding Kalman Filter Track Fitting A straight line least squares fit Details can be found: http://www.physics.ohio- state.edu/~durkin/testbeam03/TrackFnd.htm http://www.physics.ohio- state.edu/~durkin/testbeam03/TrackFnd.htm
4
02/26/2005 Emu meeting @ UC Davis 4 Data for Gatti Fitting strips time bins Largest pedestal subtracted ADC value INPUT DATA: OUTPUT: track hit position for each layer through the least squares fitting
5
02/26/2005 Emu meeting @ UC Davis 5 Something New New interface between TrackFnd and ORCA/EmuDAQ Add options of gMinuit for fitting distributions of buckeye and Gatti Change pedestal subtraction method New constants for ME11 cross talk cathode noise correlation Gatti parameters strip width and no staggering
6
02/26/2005 Emu meeting @ UC Davis 6 Buckeye Shaping 4*t c
7
02/26/2005 Emu meeting @ UC Davis 7 Peaking Time t c ME22 (t c 33.25ns) ME11(t c 28ns) ME11: smaller gas gap and wire spacing shorter drifting time
8
02/26/2005 Emu meeting @ UC Davis 8 Peak Charge Time Bins ME22 (TB2003)ME22 (TB2004)ME11 (TB2004)
9
02/26/2005 Emu meeting @ UC Davis 9 Pedestal Subtraction Standard method: subtracting first two time samples Method 2: pedestals empty event (lookup table for every strip) Method 3: pedestals fitting all available time samples for every event (buckeye shape + constant pedestal)
10
02/26/2005 Emu meeting @ UC Davis 10 Pedestal Subtraction (cont.) Method 1 – Method 2Method 3 – Method 2 ME22 (TB2004) Mean 1.041 RMS 3.17 Mean 4.322 RMS 5.901
11
02/26/2005 Emu meeting @ UC Davis 11 Pedestal Subtraction (cont.) ME22 (TB2004) ---- Method 1 ---- Method 2 ---- Method 3
12
02/26/2005 Emu meeting @ UC Davis 12 Cross Talk a function of t s determined by tracks passed within 0.05 strip width of the center of the strip ME22(TB2003) ME22(TB2004) ME11(TB2004) small statistics t s (ns) cross talk fraction
13
02/26/2005 Emu meeting @ UC Davis 13 Cathode Noise Correlation Determined from unfired strips For time bins i and j, For time bins 3, 4, 5, 6 (ADC counts) For ME22, TB2003 and TB2004 show similar results ME11 shows different noise correlation No correlations between adjacent strips’ time bins (<1 count) ME22 (TB2003)ME22 (TB2004)ME11 (TB2004)
14
02/26/2005 Emu meeting @ UC Davis 14 Gatti Parameters half gas gap (h parameter) configuration: ME22 4.75mm, ME11 3.00mm fitting: ME22 4.91mm, ME11 2.99mm strip width ME22 8.5-16.0mm, ME11 3.15-7.6mm number of wire group per layer ME22 64, ME11 48 strip staggering ME22 0.5 strip, ME11 no staggering
15
02/26/2005 Emu meeting @ UC Davis 15 2 of Gatti Fitting NDOF: 9 - 3 - 1 = 5 ME22 (TB2004)ME11 (TB2004) Investigating the large tail effect 0.08 for ME22 = 22 22 Entries Mean 4.99 RMS 3.16 Mean 4.999 RMS 3.16
16
02/26/2005 Emu meeting @ UC Davis 16 Event Displays ME22 (TB2004)ME11 (TB2004)
17
02/26/2005 Emu meeting @ UC Davis 17 Residue (3 rd Layer) ME22 (TB2004) ME11 (TB2004 ) sigma=0.0178 sigma=0.0177 3 rd layer removed from track fitting
18
02/26/2005 Emu meeting @ UC Davis 18 Comparator Ouput Resolution fitted track position - comparator output
19
02/26/2005 Emu meeting @ UC Davis 19 Left Half Hits vs Right Half Hits wrong output due to the ambiguous charge difference (see next slide)
20
02/26/2005 Emu meeting @ UC Davis 20 Output Probability wrong assignment due to the ambiguous charge difference
21
02/26/2005 Emu meeting @ UC Davis 21 Output Efficiency correct comparator output correct strip# output comparator output residue within ¾ strip
22
02/26/2005 Emu meeting @ UC Davis 22Summary Unpacking software seems robust Small changes applied to TrackFnd class For ME22, results of track fitting of TB2003 can be fully reproduced. 2 For ME11, the large tail effect of 2 and systematic errors are under investigation Comparator chip produced reasonable results for both ME11 and ME22
23
02/26/2005 Emu meeting @ UC Davis 23Next need to understand ME11 data better more refinements can be done gain effect cross talk as a function of chamber position geometry constants