Download presentation
1
SPRINGETTSBURY TOWNSHIP
2
Springettsbury Township
Wastewater Treatment Plant
3
Springettsbury Watewater Treatment Plant
Service Area WWTP History BNR Upgrade UV Disinfection Upgrade Administration Addition Construction Costs
4
Service Area Approximate Population Serviced - 70,000
Springettsbury Township Windsor Borough Red Lion Borough Yoe Borough Dallastown Borough Windsor Township And Portions of: Manchester Township Spring Garden Township York Township Approximate Population Serviced - 70,000
5
Service Area Collection System within Springettsbury Includes
120 Miles of Gravity Sewer 7 Pumping Stations 20 Miles of Forcemain
6
Springettsbury Watewater Treatment Plant
Service Area WWTP History BNR Upgrade UV Disinfection Upgrade Administration Addition Construction Costs
7
Wastewater Treatment Plant History
The Springettsbury Wastewater Treatment Plant as it appeared in 1970 The Plant was Permitted for 8 Million Gallons Per Day
8
Wastewater Treatment Plant History
In 1984 the Wastewater Treatment Plant Underwent an Upgrade and Expansion to 15 Million Gallons Per Day
9
Springettsbury Watewater Treatment Plant
Service Area WWTP History BNR Upgrade UV Disinfection Upgrade Administration Addition Construction Costs
10
BNR Upgrade Project Why Upgrade in 2011? PA DEP Bay Strategy
Biological Nutrient Removal (BNR) Reduce Nitrogen and Phosphorous discharges to the Chesapeake Bay
11
BNR Upgrade Project 2011 BNR Upgrade BNR Strategy
The main goal of this project was to design a BNR system that would meet the new effluent requirements without incurring the substantial expense of building new tanks (about 25 % more expensive).
12
BNR Upgrade Project Integrated Fixed Film System (IFAS)
Conventional Aeration Systems – Microorganisms are suspended in tank IFAS Systems – Microorganisms are attached to a suspended media; media offers greater surface area for microorganisms to grow More microorganisms: Provide higher degree of treatment Can offset the need for additional aeration basin capacity
13
BNR Upgrade Project Kruger IFAS System Media Facts -38% Fill
-85,000 CF - 274 SF/CF -23M SF - 536 ACRES
14
BNR Upgrade Project BNR System Site Plan North Train Influent
To 2nd Clarifiers Anaerobic Anaerobic Anoxic Stage #1 (N1) Oxic (IFAS) Stage #2 (N2) Oxic Stage #3 (N3) Sludge Digesters (N4) Anaerobic Influent Internal Nitrate Recycle Internal Nitrate Recycle Anaerobic Anoxic Stage #1 (N1) Oxic (IFAS) Stage #2 (N2) Oxic Stage #3 (N3) Sludge Digesters (N4) Anaerobic Anaerobic RAS South Train To 2nd Clarifiers
15
BNR Upgrade Project Media Retention Screens - 50 Screens -16” Diameter
-10’ Long
16
BNR Upgrade Project Additional Upgrades Required
New High Efficiency Diffused Air System Blowers and Blower Building Internal Mixed Liquor Recycle Pumps Conversion of Primary Clarifiers to Anaerobic/ Anoxic Selectors (anaerobic portion for phosphorous removal; anoxic portion for nitrogen removal)
17
BNR Upgrade Project Additional Plant Considerations
Motor Control Center (MCC) Upgrade Emergency Power Upgrade Final Clarifier Improvements Current Density Baffles Algae Control System Headworks Screening System Upgrade Relocated Septage Dump Station
18
BNR Upgrade Project Influent Screening is CRITICAL 3 mm opening
19
Springettsbury Watewater Treatment Plant
Service Area WWTP History BNR Upgrade UV Disinfection Upgrade Administration Addition Construction Costs
20
UV Disinfection Upgrade
Enaqua UV Disinfection System UV Lights do not Contact the water
21
UV Disinfection Upgrade
Enaqua UV Disinfection System Contact UV reactor configuration UV Lamps Flow in Flow out Front view Non - Contact UV reactor configuration UV Lamps Flow in Flow out Flow in Flow out Front view Flow tubes Side view 21
22
UV Disinfection Upgrade
23
Springettsbury Watewater Treatment Plant
Service Area WWTP History BNR Upgrade UV Disinfection Upgrade Administration Addition Construction Costs
24
Administration Addition
18 MGD Unit ready for Channel Mount Enhanced Security Required Post 9/11 Added Needed Office/Storage Space Added Multi-Use Training Room Existing Lab Updated
25
Administration Addition
26
Administration Addition
"Green" Features Use of Regional Materials for Construction New High Efficiency Geothermal Heating/ Cooling Energy Efficient Windows throughout Building Passive Heating in Conference Room Day Lighting Throughout Entire Addition
27
Springettsbury Watewater Treatment Plant
Service Area WWTP History BNR Upgrade UV Disinfection Upgrade Administration Addition Construction Costs
28
Construction Costs - General $18M - Electrical $ 4M - Mechanical $ 1M
TOTAL $23M
29
Questions?
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.