MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova P. Fabbricatore INFN-Genova The actual distance from Focus#3 and Matching#1 (first coil of Detector Coil cold mass) is 600 mm. That side of Detector Coil Cryostat shall end with a gate valve DN400. It will be shown the details of Detector Coil Cryostat end with the connection to the gate valve. Beyond the gate valve it a business of Focus Coils designers (I have no details about geometrical lay-out ) An important issue to be commonly discussed is the transmission of the axial force. In the basic configuration the Detector Coils pushes with 119 kN against Focus Coils.
2
MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Detector Coil Side to Focus Coils 600 From Match#1 end to Cryostat external surface we have 131 mm Fucus#2 and Focus#3
3
MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Details of the gate valve DN400 Ed Black indicated #1 of the Series 101 DN400 modified to have a 50 mm thick copper plate instead of lead as quoted.
4
MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Geometrical details of the gate valve DN400
5
MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova 400 510 17 mm 55 mm 20 mm 5 mm 60 mm 150 Version with o-ring ISO F standard
6
MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova 400 510 17 mm 55 mm 20 mm 5 mm 60 mm 150 Version with copper seal (CONFLAT)
7
MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Gap elementThickness (mm) Cryostat131 Connecting flange76 O-ring0-5 Gate valve150 O-ring0-5 Total357-367 Summary thickness of gap elements between Match#1 and Focus #3
8
MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Focus #1 CouplingFocus #2 Focus #3 Match #1 Match #2 End #1CenterEnd #2 +2348+168-2242+2205+232+69+1056-12-1464 -37-119 Axial forces in MICE lattice. Dimensions of Coils at RT Configuration with field profile.. Forces in kN
9
MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova F=119 kN The axial force may be reacted at the feet and/or through the gate valve connection.
10
MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova The connecting flange may be stiffened (for force transmission) More than 16 bolts may involved