Move Retinal Position: Allows you to view different regions of the retina. Location refers to the center of screen in arbitrary units Retinal region that.

Similar presentations


Presentation on theme: "Move Retinal Position: Allows you to view different regions of the retina. Location refers to the center of screen in arbitrary units Retinal region that."— Presentation transcript:

1 Move Retinal Position: Allows you to view different regions of the retina. Location refers to the center of screen in arbitrary units Retinal region that you can be stimulated. Unlike other simulation, the receptive field Might not be in this area. Select your stimulus here Control parameters of the stimulus here The firing rate of the cell is shown here Control your virtual electrode here. The grid allows you to select the cortical column being studied. The descend button moves the electrode deeper into the cortex.

2 Viewing Different Areas of the Retina Move Retinal Position: The red arrows will move in the indicated direction ¼ the visible area in that direction. That is, if the center is 0 and the right edge is 50, one click on the right red arrow will put the center at 25. It is the same proportion, not absolute movement for the vertical arrows. The position of the center of the screen on the fovea is indicated here. The units are arbitrary. Think of them as mm. The position 0,0 indicates the fovea.

3 Controlling the Stimulus You can move your stimulus across the visible retinal area by either dragging your mouse over the area or using the sliders along the sides. With these controls you can change the bar or dot width, the bar tilt (orientation) through -90 to +90 deg, and put the stimulus in the center of the visible retina. If the moving bar is used, you can reverse the direction of motion. If present, there is a checkbox you can select to show the receptive field. Select your stimulus here.

4 Output of the Cell Cell’s output. Think of the value as being number of action potentials a second.

5 Controlling the Electrode Current Position of Electrode: Recall that the cortex is divided into vertical columns. The lateral and vertical position is the current column being studied relative to the first column. The first column is the left edge of the Striate cortex, centered vertically. This will be the fovea. You can only move to the right but both up and down. The depth is the distance from the surface in number of cells recorded from. Pressing this button will allow you to record from a cell deeper in the cortex. You can record from 25 cells in any column. Once a cell has been left it cannot be accessed again Each white square represent a different column on the cortex. Click on that square to start recording from that cortex, starting with a cell nearest the surface. When you select a column, that column will be grayed out. Once you leave a column you cannot again record from that column again. This control will allow you to select a new region of brain whose column you wish to record from. Initially you can move up, down, and to the right. Once you have left a brain region, you cannot return and record from any other cells in that region.