Measurement of the muon anomaly to high and even higher precision David Hertzog* University of Illinois at Urbana-Champaign * Representing the E821 Collaboration: Boston, BNL, Budker Inst., Cornell, KFI, Heidelberg, Illinois, KEK, Minnesota, Tokyo Tech, Yale & new E969 groups: JMU, Kentucky, LBL/UC-Berkeley
2
Outline The muon is a little brother of the tau n The “old” BNL experiment With the 2004 result on - n The theoretical ingredients and overall motivation u Lots will follow today by the real experts n The “new” experiment – 0.2 ppm is the new goal u Some fresh new ideas and bold ambition u Approved this week at BNL with Highest “Must Do” Status
3
(1) Precession frequency (2) Muon distribution (3) Magnetic field map Muon g-2 is determined from 3 measurements B
4
And, 4 miracles make it happen n P olarized muons
5
Muons are created from in-flight decay and enter ring in a bunch
6
And, 4 miracles make it happen n P olarized muons P recession proportional to ( g -2) µ
7
Momentum Spin e The muon spin precesses faster than the cyclotron frequency: a is proportional to the difference frequency
8
And, 4 miracles make it happen n P olarized muons P recession proportional to ( g -2) P The magic momentum E field doesn’t affect muon spin when = 29.3 µ
9
BNL Storage Ring incoming muons Quads KICK 0 500 ns 100 kV Only a few percent get stored!
10
Magnetic Field Continuously monitored using 150 fixed probes mounted above and below the storage region Measured in situ using an NMR trolley 1 ppm contours 0.05 0.09 0.05 0.07 0.10 0.17 2001
11
And, 4 miracles make it happen n P olarized muons P recession proportional to ( g -2) P The magic momentum E field doesn’t affect muon spin when = 29.3 n P arity violation in the decay µ
12
2.5 ns samples Measuring the difference frequency “ a ” e+e+ TIME Counts < 20 ps shifts < 0.1% gain change
13
Few billion events Getting a good 2 is a challenge Fit to Simple 5-Par Function N(t) = N 0 e -t/ [1+Acos( a t + )]
14
Fourier Spectrum of Residuals to 5-par Fit f g-2 ≈229 KHz f CBO ≈466 KHz In 2001, we adjusted the ring index to avoid overlap
15
Detector “Swims” Beam into storage volume Detector “Breathes” (smaller effect) Coherent Betatron Oscillations Radius Acceptance Inflector mapping to storage volume Acceptance vs average radius
16
Modulation of N 0, A, with f cbo
17
Pileup Subtraction Phase shift possible Separate when you can... low rate deadtime corrected Energy of positrons Extrapolate to zero deadtime on average using out-of-time resolved events Build pileup-free histogram with deadtime
18
Muon Loss & Stored Protons Excess loss rate Constant loss rate Uncertainty, mostly due to protons muon decay hit Account for “slow effects” by correction of muon flux in ring beyond exponential decay Do these muons have a different phase ?
19
Internal Consistency: Chi-Sq, Run # Normalized 2 vs. Start Time of Fit Precession Frequency vs. Run Number
20
Internal Consistency: Start Time, Detector, Energy Precession Frequency vs. Detector # Precession Frequency vs. Fit Start Time Precession Frequency vs. Energy Band
21
Five complementary analyses of a Low n (black), high n (clear), combined (red) data sets. G2off production 9-parameter ratio G2Too production 3 - parameter ratio with cancellation G2off production Multi-parameter G2off production Multi-parameter quad corrections G2Too production Multi-parameter, E th =1.5 GeV asymmetry-weighted,
22
The new result is in excellent agreement with previous measurements on + g-2 Collaboration: PRL 92 161802 (2004) a = 11659214.0(8)(3) 10 -10 (0.7 ppm) -
23
g ≠ 2 because of virtual loops, many of which can be calculated very precisely B QED Z Weak Had VP Had LbL Many of the next 8! talks will discuss the standard model theory
24
Hadronic vacuum polarization is obtained from e + e - and/or tau data h µ h -- h e+e+ e-e- is related toand also
25
The - e + e - comparison Davier, et al hep-ex/00308214 Jan 04 Difference is significant AND energy dependent
26
Pion Formfactor CMD-2 KLOE 0.40.50.60.70.80.9 s [GeV 2 ] 45 40 35 30 25 20 15 10 5 45 0 From G. Venanzone And, from ICHEP, A. Hocker is stepping back from the Tau result until isospin issues are fully understood: Today, we’ll hear about the latest KLOE “confirmation” of CMD2
27
Comparison of final results and theory a (world avg = 11 659 208(6) 10 -10 (0.5 ppm) ee =25±9 Includes new HLbL shift and KLOE result ee- marriage ± Opps Divorce! Opps2 KLOE
28
Discrepancy with e + e - based theory n What might this mean? n New physics or a fluctuation
29
Non-zero a appeals to a catalog of SM Extensions New physics … SUSY Leptoquarks Muon substructure Anomalous W couplings µ µ W µ W B Sensitive for supergravity grand unification, especially for large tan Chargino-Sneutrino Neutralino-Smuon tan = 10 100 300 500 700 900 -50 50 0 100 a SUSY [ 10 -10 ] smuon mass (GeV) ee -expt tau -expt
30
Courtesy K.Olive based on Ellis, Olive, Santoso, Spanos In CMSSM, a can be combined with b→s , cosmological relic density h 2, and LEP Higgs searches to constrain mass Allowed band a (exp) – a (e+e- thy) Excluded for neutral dark matter Preferred tan =10 Excluded by direct searches
31
Same Discrepancy Standard Model a 25(5) x 10 -10 (5 a 0 (5) x 10 -10 Two “futures” when new experiment and improved theory are complete
32
E969 is a new g-2 experiment at BNL Strategy is basic: Get more muons – E821 was statistics limited ( stat = 0.46 ppm, syst = 0.3 ppm) u AGS 20% more protons u Backward-decay beam u Higher-transmission beamline u New, open-end inflector u Upgrade detectors, electronics, DAQ Reduce B, systematic uncertainty on magnetic field, B u Improve calibration, field monitoring and measurement Reduce a systematic uncertainty on precession, ω a u Improve the electronics and detectors u New parallel “integration” method of analysis n Keep the main ideas and ring Expect 5 x more rate
33
E821 used forward decay beam, which permitted a large component to enter ring Pions @ 3.115 GeV/c Decay muons @ 3.094 GeV/c Pedestal vs. Time Near sideFar side This baseline limits how early we can fit data
34
New experiment uses a backward decay beam with large mismatch in momentum at final slits Expect for both sides Pions @ 5.32 GeV/c Decay muons @ 3.094 GeV/c No hadron-induced prompt flash Approximately the same muon flux is realized x 1 more muons
35
Decay region will include more quads to capture muons Lattice doubled E821 lattice x 2 more muons
36
Improved transmission into the ring Inflector Inflector aperture Storage ring aperture E821 Closed EndP969 Proposed Open End Outscatters muons x 2 more muons
37
Systematic Error Evolution by Factor of 2 n Field improvements will involve better trolley calibrations, better tracking of the field with time, temperature stability of room, improvements in the hardware n Precession improvements will involve new scraping scheme, lower thresholds, more complete digitization periods, better energy calibration Systematic uncertainty (ppm)1998199920002001E969 Goal Magnetic field – p 0.50.40.240.170.1 Anomalous precession – a 0.80.3 0.210.1
38
E969: Precession Measurement n Expect 5 x more rate u Segment calorimeters u 500 MHz waveform digitization u Greatly increased data volume for DAQ n Introduce parallel “Q” method of data collection and analysis u Integrate energy flow vs. time T Method Q Method
39
Starting ideas for new, fast, dense and segmented W-SciFi calorimeters n 20-fold segmentation n 0.7 cm X 0 n 14%/Sqrt(E) n Greatly constrained space
40
Conclusions n E821 was very successful, reaching 0.5 ppm final uncertainty n Theory has gone from 5 ppm → 0.6 ppm during same time period Today’s status: tantalizing 2.7 discrepancy n Next phase includes new, approved experiment and continued work on hadronic issues related to theory u KLOE, BaBar, Belle, radiative corrections, lattice, … u Together, expect reduction in expt-thy comparison by x 2 hertzog@uiuc.edu
41
Extra Slides Follow
42
Field Uncertainties - History * higher multipoles, trolley voltage and temperature response, kicker eddy currents, and time-varying stray fields. Source of Uncertainty 1998199920002001 Absolute Calibration0.05 Calibration of Trolley0.30.200.150.09 Trolley Measurements of B0 0.10.10 0.05 Interpolation with the fixed probes 0.30.150.100.07 Inflector fringe field0.20.20-- uncertainty from muon distribution 0.10.120.03 Other*0.150.10 Total 0.50.40.240.17
43
Systematic errors on ω a (ppm) σ systematic 1999 2000 2001E969 Pile-up0.13 0.080.07 AGS Background0.10 * Lost Muons0.10 0.090.04 Timing Shifts0.100.02 E-Field, Pitch0.080.03*0.05 Fitting/Binning0.070.06* CBO0.050.210.070.04 Beam Debunching0.04 * Gain Change0.020.13 0.03 Total0.30.310.210.11 Σ* = 0.11
44
The - decay input to H-VP n Data precise n Related by CVC with corrections Isospin asymmetry ( vs W-W- Issues with mass and width raised last year u Long-distance radiative corrections Bottom line, can the data contribute in the long run at sub % level?