SPRAY COATER REPORT Pierre Ponce 4/15/2010
2
Operation The AccuMist nozzle is NOT centered when the head is at the 0 angle position – Tested using Center Test Recipe. – Centered when the indicator is halfway b/w 0 and the next tick towards the back of the machine. Center test also fails unless the swivel arm if first homed and then moved to parkposition.
3
Recipes P16-P32 Resist Blend SPR220-7:MEK:EL (1:8:5) All wafers are clean, flat silicon (L-test) 150 C singe oven before spraying Chuck at 65 C and wafers sit for 30 seconds before each (CCW spin, CW spin) pair of coats Chuck spins at 80 RPMs After recipe ends, vacuum hotplate at 90 C for 120secs (done at svgcoat) Swivel arm height fixed at 800000 Swivel arm speed profile derived from Matlab script (13 steps from edge to edge), starting at 265 steps/sec
4
Variables Nozzle pressure (400, 600, 800, 1200, 1600 mTorr) Number of passes (6, 10, 12) Dispense rate (10, 6, 5 uL/s)
5
Observations #Passes (or Dispense rate ) Standard deviation Pressure Roughness (maybe) Pressure Center thickness Pressure Edge thickness Spin rate Edge roughness – (tested 1 wafer at 50 RPM, recipe P31) High speed at edge seems bad for roughness… Possible solutions – 1. Less chuck spin rpm and/or – 2. Scale down swivel arm speed
6
Next Tests Less RPMs Reduce arm speed by 0%, 25%, 50% Fix #passes to 12 Use 1200 mTorr as min pressure up to 1600 Raise chuck temperature to 75 C Standard topography tests (are there standard topography wafers available?)